background image

TENAYA2® SERIES

 

Component Installation

Warning

High Voltage

Hot Surface

3/16”, 7/64” & 1/8” Allen Wrench
Level
Hammer
Phillips Screwdriver

NEEDED

FOR 

INSTALLATION:

By Others

RELEASE DATE

12-6-16

REFERENCE

 

NUMBER

INS-2145-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

Tenaya2® and its features are covered in whole or in part by U.S. Patent No. 7,175,297; U.S. Patent No. 7,033,038; U.S. 

Patent No. 6,254,258 B1; U.S. Patent No. 7,553,042;  and U.S. Patent No.  7,560,148.

Driver

Enclosure

Solid Silicone 

Faceplate Gasket

 OptiLock™ 

and Optic

Driver Input

Driver Output

Optical Chamber

Faceplate

Patented Leveling Collar

Concrete Pour Collar

Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.

 

·  Suitable for wet locations ·  Suitable for recessed in ground locations

IMPORTANT LISTINGS AND CERTIFICATIONS

1A. For soil installation, clear soil around temporary 

cover to prevent debris falling into the housing.  

Remove temporary cover.

1B. For a concrete installation, break through the 

disposable Yellow Installation Cover with a claw-

hammer or pry-bar, then grasp the cover and pull 

straight up to leave a smooth, finished edge.

 NOTE: Temporary Cover is recyclable.

For Soil

For Concrete

• Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local and 

Provincial Codes. 

•  Follow product label information and instructions.

• Qualified Personnel with appropriate personal protective 

equipment must perform all servicing of this product.

•  Before wiring to power supply and during servicing, turn off and 

lock out power at fuse or circuit breaker before service.

• The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause an 

unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

•  Do not block light emanating from product in whole or part, as 

this may cause an unsafe condition.

• Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. 

•  Replace LED assembly only with correct wattage and type of 

power supply appropriate for LED assembly.

• All gaskets, o-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted fixture is HOT!

WARNING - To reduce the risk of 

FIRE OR INJURY TO PERSONS: 

Turn off/unplug and allow to cool before replacing LED. 

Fixture gets HOT quickly! Contact only switch/plug when 

turning on.  Do not touch hot lens, guard, or enclosure. 

Keep fixture away from materials that may burn. 

 

Do not operate the luminaire fitting with a missing or 

damaged shield.  Do not touch the source at any time. Use 
a soft cloth or gloves. Oil from skin may cause damage.

SAVE THESE INSTRUCTIONS

Summary of Contents for Tenaya 2 Series

Page 1: ...rn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition The use of damaged components may cause an unsafe condition and void product warranty IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from...

Page 2: ...ve sufficient clearance to elevate housing to finished grade Top of yellow temporary cover level to finished grade 4 Raise housing on EMT to finished grade top of yellow temp cover Use bubble level on yellow temporary cover to aid in leveling housing 5 When top of yellow temporary cover is level with finished grade tighten screws on Stability Flange to secure housing to EMT Remove excess EMT as ne...

Page 3: ...be level with the top of the Yellow Installation Cover Soil installation is NOT Drive over rated Concrete Drive over Soil 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage 8 Rotate patented HydroLock plate counter clockwise to allow notch in HydroLock plate to clear pins on junction box Pull to remove 9 Pull branch circuit wiring and extern...

Page 4: ...Concrete Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power sup...

Page 5: ...he optical chamber horizontally 360 rotate the optical chamber to desired direction 8 For Optional Internal Cutoff Place internal cutoff louver in the top of the optical chamber in the desired direction of cutoff and install faceplate as normal Optional Internal Cutoff 7 Before Installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE...

Page 6: ...n to 25 in lbs 5 Remove optic holder by loosening two 2 4 40 screws using a 0 05 Allen wrench 6 Carefully remove LED module from heatsink Do not pull on connector or wiring Handle with care Fragile Do not pull on connector or wiring Handle with care 7 Use small pick tool to push connector off LED board through two small slots behind connector Once loose lift connector upwards and off board 8 Place...

Page 7: ...Tighten 2 6 32 set screws to secure accessory bracket to OptiLock as shown 15 Before Installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE TO DO THIS STEP WILL CAUSE FIXTURE TO FAIL AND VOID PRODUCT WARRANTY 13 If your Tenaya2 comes with optional accessory holder see Relamping with Accessory Holder to remove and install source To ...

Page 8: ...RUCTIONS 3 Insert up to 2 accessories into the accessory holder Accessories should rest on lip of accessory holder NOTE 1 Insert any accessory lens with the smooth side toward the LED 2 If using a honeycomb baffle position it farthest from the LED Accessory Replacement 4 Place accessory holder onto tabs on accessory bracket over optic 1 Pull accessory holder from accessory bracket 2 Optic should r...

Page 9: ...ighten two set screws 2 Install the faceplate using 3 16 Allen wrench and torque the faceplate screws in a cross pattern to 25 in lbs Rock Guard w Optical Opening Rock Guard Half Dome Glare Shield 1 Before installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE TO DO THIS STEP WILL CAUSE FIXTURE TO FAIL AND VOID PRODUCT WARRANTY Fac...

Reviews: