17. Install the faceplate using 3/16” Allen wrench
and torque the faceplate screws in a cross
pattern to 25 in-lbs.
TENAYA2® SERIES
Relamping & Accessories
RELEASE DATE
12-6-16
REFERENCE
NUMBER
INS-2145-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
11. Install reflector by placing in LED reflector
holder, then twisting gently to the right under
tabs.
12. Place accessory holder onto tabs on accessory
bracket, lined up with notches in holder.
10. Place accessory holder on OptiLock™, lining
up holes in bracket on OptiLock™. Tighten (2)
#6-32 set screws to secure accessory bracket to
OptiLock™ as shown.
15. Before Installation of faceplate, clean solid
silicone faceplate gasket (see arrows) and collar
of debris for a proper seal.
FAILURE TO DO THIS STEP WILL CAUSE
FIXTURE TO FAIL AND VOID PRODUCT
WARRANTY.
13.
If your Tenaya2® comes with optional
accessory holder, see “Relamping with
Accessory Holder” to remove and install
source.
To aim the OptiLock™ inside the optical
chamber horizontally 360°, rotate the optical
chamber to desired direction.
16.
For Optional Internal Cutoff:
Place internal
cutoff louver in the top of the optical chamber
in the desired direction of cutoff and install
faceplate as normal.
Optional Internal Cutoff
14. To aim the OptiLock™ inside the optical
chamber vertically, loosen the four (4) #10-
24 screws using 1/8” Allen wrench and tilt
OptiLock™ to desired vertical direction. Tighten
all screws when aiming is complete.