![B-K lighting Tenaya 2 Series Manual Download Page 5](http://html.mh-extra.com/html/b-k-lighting/tenaya-2-series/tenaya-2-series_manual_460962005.webp)
Fixture Installation
TENAYA2® SERIES
Component Installation
up to 30° of rotation
Faceplate
screw
locations
2. Place the Patented Leveling Collar on the four
adjustable posts. Each adjustable post can be
raised or lowered using a Phillips screwdriver.
Leveling collar also allows for 30° of rotation to
align faceplate screws with one another. When
collar is level, and faceplate screw holes are
aligned to final position, secure the collar with
the four hex nuts provided.
3. Place the driver enclosure in the driver
compartment. Connect the primary/input cable
from the driver to the patented HydroLock®
plate located in the housing as shown.
4. Connect the output/secondary cable on the
driver to the bottom of the optical chamber.
5.
If your Tenaya2® comes with optional
accessory holder, see “Relamping with
Accessory Holder” to remove and install
source.
To aim the OptiLock™ inside the optical
chamber horizontally 360°, rotate the optical
chamber to desired direction.
8.
For Optional Internal Cutoff:
Place internal
cutoff louver in the top of the optical chamber
in the desired direction of cutoff and install
faceplate as normal.
Optional Internal Cutoff
7. Before Installation of faceplate, clean solid
silicone faceplate gasket (see arrows) and collar
of debris for a proper seal.
FAILURE TO DO THIS STEP WILL CAUSE
FIXTURE TO FAIL AND VOID PRODUCT
WARRANTY.
9. Install the faceplate using 3/16” Allen wrench
and torque the faceplate screws in a cross
pattern to 25 in-lbs.
RELEASE DATE
12-6-16
REFERENCE
NUMBER
INS-2145-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
6. To aim the OptiLock™ inside the optical
chamber vertically, loosen the four (4) #10-
24 screws using 1/8” Allen wrench and tilt
OptiLock™ to desired vertical direction. Tighten
all screws when aiming is complete.