B-K LIGHTING

REFERENCE NUMBER

INS-2406-00

Standard Installation

 CO2

INTEGRAL - LED

Conduit
trench

18”

Dia.

1.  Determine Soil Type by referencing DIG-IT Guide. 

2.  Dig hole 18” wide and 18” deep.

Conduit

Trench

Excavated 

for Housing

3.  Prep soil according to DIG-IT Guide.

Soil Prep

Housing Installation

2.  Place housing in hole. Align junction box in the path 

of the conduit trench.

3.  Insert four (4) pieces of ½” PVC/EMT conduit 

through the Stability Flange. Hammer into substrate  

until secure.

 Leave sufficient clearance to elevate housing to 

finished grade.

4.   Raise housing on PVC/EMT so housing is flush 

with finished grade. Use a level  to aid in housing 

installation.  

5.  When housing is level, tighten screws on Stability 

Flange to secure housing to PVC/EMT. Remove 

excess PVC/EMT as needed.

Flush with finished grade

6.   Pull primary branch circuit wiring into junction 

box.  

1.  Connect branch conduit connectors (not included) 

to the junction box using either the threaded 

conduit entries on the bottom of the junction box or 

through holes drilled into the sides of the junction 

box. 

 Recommend 7/8” hole saw to open threaded entry 

hole.

SCAN WITH SMART DEVICE OR CLICK THE BAR 

CODE  FOR ONLINE DIG-IT GUIDE

Threaded Entry

Side Flats

Summary of Contents for CO2

Page 1: ...ing to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary...

Page 2: ...our 4 pieces of PVC EMT conduit through the Stability Flange Hammer into substrate until secure Leave sufficient clearance to elevate housing to finished grade 4 Raise housing on PVC EMT so housing is...

Page 3: ...at faceplate Insert stakes through stability flange Top of grout mask should be flush with grade 9 For concrete installation Fill the hole around the fixture housing to 12 below the finished grade wi...

Page 4: ...al or water may intrude This step must be done as stated or you will void your warranty HydroLock Plate HOT BLACK NEUTRAL WHITE GROUND GREEN 0 10V VIOLET 0 10V GRAY WIRING DIAGRAM 0 10V Dimming All li...

Page 5: ...8 allen wrench and hand tighten the faceplate screws in a star pattern to 30 in lbs min Do not use a power tool to install screws Do not exceed 40 in lbs 9 To aim OptiLock vertically loosen two 2 1 4...

Page 6: ...f applicable 2 Turn then lift OptiLock from housing Disconnect OptiLock assembly from driver assembly using quick disconnect 9 Attach OptiLock assembly to installed driver assembly with quick disconne...

Page 7: ...o ring groove near top of housing Place o ring inside of groove Failure to clean groove of debris will cause fixture to fail and void product warranty 11 To aim OptiLock horizontally lift OptiLock fr...

Page 8: ...with quick disconnect Place OptiLock assembly in housing resting the OptiLock on the pins provided inside the housing Gravity will hold OptiLock in place 4 Use a 0 050 allen wrench to loosen three 3...