11. Attach tether wire under screw head at the base
of the UPM housing. Slowly lower the faceplate
until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
REVISION DATE
7-27-09
REFERENCE NUMBER
INS-1515A
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM1RM ROUND CAMLOCK™
Recessed junction box installation
Ground
Hot
Neutral
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE IN UPM
BLACK
WHITE
XFMR
RED
RED
TO FIXTURE
A
B
C
Wiring Diagram.
9.
Pull secondary leads into UPM housing and
connect to transformer secondary leads using
approved wire connectors (By Others).
5.
Feed branch circuit wiring into UPM housing.
Install housing on CamLock™ at 90° to finished
orientation as shown. (Figure A)
6.
Rotate housing 90° counter-clockwise (Figure B).
Tighten set screw with 5/64” allen wrench on
outside of UPM housing to lock in place.
(Figure C)
7.
If UPM housing is not level, remove UPM
housing; loosen but
DO NOT REMOVE
(2) #8-32
screws with 9/64” allen wrench on CamLock™
assembly. Adjust CamLock™ assembly up to 30°
as needed to level. Tighten the screws and
reattach UPM housing.
8.
Use wire connectors (By Others) to connect
transformer primary leads to branch circuit wires.
Connect incoming ground to ground wire
provided in UPM housing. See wiring diagram.
10. Remove the backing from adhesive tape on
transformer, place in bottom of UPM housing
void of any wiring and press firmly for five
seconds to ensure good contact.
12. Make sure UPM body gasket is free of any dirt or
debris. Attach the faceplate by tightening the (4)
#6-32 captive screws evenly to 6-9 in/lbs using a
5/64” allen wrench.
4.
Feed branch circuit wiring and lamp leads to
remote mounted fixture through mounting plate
with CamLock™ assembly. Attach mounting plate
with supplied (2) #10-24 stainless steel hex drive
fasteners to universal ring using 1/8” allen
wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250