REVISION DATE
7-27-09
REFERENCE NUMBER
INS-1514
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM1RM TREE STRAP™
Tree Strap™ Installation
5.
Pull branch circuit wiring necessary for
installation (By Others.)
9.
Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower the
faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety
cable. Do not add weight to, or drop faceplate.
Ground
Hot
Neutral
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE IN UPM
BLACK
WHITE
XFMR
RED
RED
TO FIXTURE
Wiring Diagram.
7.
Pull secondary leads into UPM housing and
connect to transformer secondary leads using
approved wire connectors (By Others).
6.
Use wire connectors (By Others) to connect
transformer primary leads to branch circuit wires.
Connect incoming ground to ground wire
provided in UPM housing. See wiring diagram.
10. Make sure UPM body gasket is free of any dirt or
debris. Attach the faceplate by tightening the (4)
#6-32 captive screws evenly to 6-9 in/lbs using a
5/64” allen wrench.
8.
Remove the backing from adhesive tape on
transformer, place in bottom of UPM body void
of any wiring and press firmly for five seconds
to ensure good contact.
4.
Connect 1/2” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit pipe with a suitable
sealant (Teflon tape, adhesive, etc). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250