REVISION DATE
7-27-09
REFERENCE NUMBER
INS-1516
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM1RM SURFACE MOUNT
Surface Mount installation
4.
Attach the UPM housing at mounting brackets
with ¼” fasteners (by others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
5.
Connect 1/2” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance for
water if not properly sealed. Seal connector
threads and conduit with a suitable sealant
(Teflon tape, adhesive, etc.). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
6.
Pull branch circuit wiring necessary for
installation (By Others.)
10. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
Ground
Hot
Neutral
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE IN UPM
BLACK
WHITE
XFMR
RED
RED
TO FIXTURE
Wiring Diagram.
8.
Pull secondary leads into UPM housing and
connect to transformer secondary leads using
approved wire connectors (By Others).
7.
Use wire connectors (By Others) to connect
transformer primary leads to branch circuit wires.
Connect incoming ground to ground wire
provided in UPM housing. See wiring diagram.
11. Make sure UPM body gasket is free of any dirt or
debris. Attach the faceplate by tightening the (4)
#6-32 captive screws evenly to 6-9 in/lbs using a
5/64” allen wrench.
9.
Remove the backing from adhesive tape on
transformer, place in bottom of UPM housing
void of any wiring and press firmly for five
seconds to ensure good contact.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250