10. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
REVISION DATE
7-27-09
REFERENCE NUMBER
INS-1515B
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
PM1RM RECTANGULAR CAMLOCK™
Recessed junction box installation
Ground
Hot
Neutral
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE IN UPM
BLACK
WHITE
XFMR
RED
RED
TO FIXTURE
Wiring Diagram.
8.
Pull secondary leads into UPM housing and
connect to transformer secondary leads using
approved wire connectors (By Others).
6.
If UPM housing is not level, remove UPM
housing; loosen but
DO NOT REMOVE
(2) #8-32
screws with 9/64” allen wrench on CamLock™
assembly. Adjust CamLock™ assembly up to 30°
as needed to level. Tighten the screws and
reattach UPM housing.
7.
Use wire connectors (By Others) to connect
transformer primary leads to branch circuit wires.
Connect incoming ground to ground wire
provided in UPM housing. See wiring diagram.
11. Make sure UPM body gasket is free of any dirt or
debris. Attach the faceplate by tightening the (4)
#6-32 captive screws evenly to 6-9 in/lbs using a
5/64” allen wrench.
9.
Remove the backing from adhesive tape on
transformer, place in bottom of UPM housing
void of any wiring and press firmly for five
seconds to ensure good contact.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250