1ª 10155 ES 9 - 2009
50
x
ELA1
: Fault type 1 in extraction motor. Not freed microswitch at end of cycle.
Cause: Motor disconnected or faulty.
Problem in microswitch or wiring.
x
ELA2
: Fault type 2 in extraction motor. 6 seconds gone by from after freeing microswitch
and it has not been re activated.
Cause: Jam of a packet.
Motor excessively slow.
x
ELA3
: Fault type 3 in extraction motor. The cycle of the motor has finished correctly, but
the microswitch for empty product channel not freed.
Cause: Jam of a packet.
Microswitch of empty channel faulty or wiring.
x
ELA4
: Fault type 4 in extraction motor. Two changing states of microswitch detected with
machine in standby. Deactivate security relay and the machine goes out of order.
Cause: Transistor short circuited in the extraction board.
Exit control activated by transistors or electrostatics discharges.
Short circuit in extraction boards.
x
EKA
: Fault in the card reader
x
EPA
: Fault in the bill reader
x
OEZI
: Activation of reception of infrared. Can come from incorrect use of the remote
control, by discharges from lighters, lightning or the use of non authorised remote
controls.
x
OEZA
: Communication following the protocol VTM of Azkoyen.
x
EGS
: Door opened
x
EGT
: Door closed