1ª 10155 ES 9 - 2009
49
MESSAGE
EVENTS IN FUNCTION 098
Definition
Events in the machine with date and time. With a maximum of 128,
erasing the first after this quantity.
x
OEZN
: Switch on machine.
x
OEZF
: Switch off machine.
x
ECZC
: Reset configuration.
x
ECZP
: Reset programming of channels, prices, associations, family codes and product
codes.
x
ECZM
: Reset message programme.
x
ECZO
: Reset of accounting
x
ECZT
: Reset of table of functions of the basic menu
Cause: These reset codes happen when they are not written to RAM correctly.
x
ECZS
: Reset of SDB
x
EIR
: Communication problem in the MDB payment system
x
EAN1
: Fault type 1 in change giver. Number of coins is not extracted correctly.
x
EAN2
: Fault type 2 in change giver. Photocells in the way out of the change giver blocked.
x
EAN3
: Fault type 3 in a extractor. Three coins were detected in standby mode. The
security relay is activated and it goes out of order.
Cause: Transistor short circuited in the hopper control board.
Exit control activated by transistors or electrostatic discharges.
Short circuit in hopper control board.
x
EAN4
: Fault type 4 in change giver. Communication problem in the change giver.
x
EAN5
: Fault type 5 in change giver. Photocell locked permanently during payment
x
EAL
: Fault validator
x
EAM
: Fault in the clasificator of coins.
x
EAR
: Fault in the “V” escrow of three flaps.
x
EAB
: Fault in the module of refund.
x
ELZ2
: Fault type 2 in the extraction board modules.
x
ELZ3
: Fault type 3 in the extraction board modules.
Summary of Contents for STEP 41
Page 28: ...1 10155 ES 9 2009 28 Below are the technical characteristics...
Page 29: ...1 10155 ES 9 2009 29...
Page 57: ...1 10155 ES 9 2009 57...