background image

Document #101-0007

       1

       9/12/05

RNS, DRS, & ER-60 M-Line

 Operational Manual

Summary of Contents for DRS

Page 1: ...Document 101 0007 1 9 12 05 RNS DRS ER 60 M Line Operational Manual ...

Page 2: ...II VALIDATOR MOUNTING 5 10 STAMounting Instructions 5 STA Stacker Mounting Diagram 6 Coinco Mars Mounting Instructions 7 Coinco Parts Layout 8 Mars Parts Layout 9 Parts Index 10 III PARTS 11 12 APPENDICES APPENDIX A 1 H Harness Diagram 13 APPENDIX B Bill Denomination Mylar Instructions 14 ...

Page 3: ... assistance from the manufacturer please call 800 837 5561 or 419 867 4858 When calling for assistance it is very important to have serial numbers readily available Please record these numbers in the spaces provided Note that the DRS has dual components RNS DRS ER 60 SERIAL VALIDATOR MODEL SERIAL VERSION MODEL DRS SINGLE STACKER SERIAL MODEL DRS DUAL STACKER SERIAL MODEL DRS HOPPER SERIAL MODEL DR...

Page 4: ...24 3 4 H x 18 W for ER 60 Electrical This changer is operated on 120 VAC 60 Hz This changer uses a 5AMPCIRCUITBREAKER This unit may be hard wired with conduit if desired AGROUND FAULTINTERRUPTER IS REQUIRED The recommendedGroundFaultInterruptershouldhavethefollowingspecifications 120 VAC 15 AMP 6 10mA trip level Should not trip when power is removed from circuit Attached to the main harness is a 1...

Page 5: ...nt and remove it as well 4 Secure the newValidator mounting bracket assembly 37 0055B to the studs on the front wall of the cabinet using four 1 4 20 nuts 5 Secure the adhesive backed foam seal to the inside of the cabinet front around theValidator opening 6 Connect the small end of the 9 pin harness adapter to the STAValidator and the other end to the system harness 7 Slide theValidator into theV...

Page 6: ...Document 101 0007 6 9 12 05 STA Stacker Mounting ...

Page 7: ... 17 toValidator Plate 7 Screwing them frominsidetoout 5 Then mount Security Bracket 1 to the bottom of the two Phillister head screws so it swings up and down 6 Take U Channel 5 and place it inside ofValidator Plate 7 and match up with studs on face of cabinet 7 Then by taking 4 1 4 20 Hex nuts 3 and 4 1 4 internal lock washers 4 mount to cabinetandtightendown 8 Then takeValidator and place into U...

Page 8: ...Document 101 0007 8 9 12 05 Coinco Parts Layout COINCO VALIDATOR CABINET FACE LEXAN CABINET DOOR 17 16 15 14 1 13 12 11 10 9 8 7 6 5 4 3 2 ...

Page 9: ...Document 101 0007 9 9 12 05 CABINET FACE LEXAN MARS VALIDATOR CABINET FACE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Mars Parts Layout ...

Page 10: ...2 X 5 8 BALL STUD 4 13 90 0148 10 24 X 3 8 PHILLIPS HEAD SCREW 2 17 90 0628 10 32 X 3 16 PHILLISTER HEAD 4 ITEM PART MOUNTING PARTS FOR MARS QTY 1 60 2055 SECURITY BRACKET 1 2 90 0145 8 32 X 5 8 PHILLIPS HEAD SCREW 4 3 90 0331 1 4 20 HEX NUT 4 4 90 0403 1 4 INTERNAL LOCK WASHER 4 5 60 2051 U CHANNEL 1 6 90 0629 10 32 X 1 2 THUMB SCREW 1 7 60 2050 VALIDATOR PLATE 1 8 90 0321 8 32 NYLON NUT 4 9 60 2...

Page 11: ...004A AUDIT PRO CONTROLLER 1 49 2010A AUDIT PRO HANDHELD REMOTE 1 48 2111A AUDIT PRO HARNESS 1 60 0084 COVER LOCK UNISTRUT BRACKET 2 60 0346A DRS ACCESS SHIELD 1 60 0347A RNS ACCESS SHIELD 1 60 0349A ER 60 ACCESS SHIELD 1 61 2000A ER 60 M CABINET COMPLETE 1 61 2002A DRS M CABINET COMPLETE 1 61 2003A RNS M CABINET COMPLETE 1 63 0318A WEATHERSHIELD ASSM 1 63 2001B ER 60 M FACE PANEL ASSM 1 63 2002B D...

Page 12: ...CKER 1 46 0200 MARS VALIDATOR INCLUDES STACKER 1 PART OTHER QTY 48 0006 HEATER ASSM 1 48 1016 DRS HOPPER EXTENSION HARNESS RIGHT 1 48 1017 DRS HOPPER EXTENSION HARNESS LEFT 1 48 2115A DUAL HVX EXTENSION HARNESS 1 48 2115B DUAL HVX ADDITION HARNESS 1 60 0271 DUAL STACKER PLATE RIGHT 1 60 0272 DUAL STACKER PLATE LEFT 1 60 0273 STACKER BRACKET RIGHT 1 60 0274 STACKER BRACKET LEFT 1 60 0275 COMBINATIO...

Page 13: ...Document 101 0007 13 9 12 05 APPENDIX A 1 H Harness Diagram ...

Page 14: ...e NUTS from the BALL STUDS 2 Remove the BALLSTUDS from the FACE PLATE 3 Insert the BILLDENOMINATION MYLAR between the FACE PLATE and the PLASTIC PANEL until the holes in the BILLDENOMINATION MYLAR line up with the holes in the FACE PLATE 4 Reinsert the BALLSTUDS into the front of the FACE PLATE through the BILLDENOMINATION MYLAR and the PLASTIC PANEL 5 Replace the NUTS on the BALL STUDS and tighte...

Page 15: ...of God natural disaster acts of war or terrorism 2 The Seller shall not be liable for any expense incurred by Purchaser inci dental to the repair or replacement of equipment and Purchaser shall assumefullresponsibilityforanyfreightorshippingcharges 3 The coverage of this warranty shall not extend to expendable parts 4 Purchaser shall have a warranty registration card on file with Seller prior to a...

Page 16: ...duetobillmanipula tion or theft or loss of cash under any circumstances 8 No person or entity other than a factory trained representative or Hamilton Manufacturing Corp has performed or attempted to perform the subject repair or service THISAGREEMENTISMADEWITHTHEEXPRESSUNDERSTANDINGTHATTHEREARE NO IMPLIED WARRANTIES THATTHE EQUIPMENT SHALLBE MERCHANTABLE OR THAT THE GOODS SHALL BE FIT FOR ANY PART...

Page 17: ...Document 101 0007 17 9 12 05 ...

Page 18: ...800 837 5561 Customer Service Fax 419 867 4857 Advanced Systems Phone 866 296 3365 Advanced Systems Fax 419 867 4857 Parts Phone 866 835 1721 Parts Fax 419 867 4867 Website http www hamiltonmfg com Email Addresses service hamiltonmfg com sales hamiltonmfg com parts hamiltonmfg com info hamiltonmfg com Hamilton Manufacturing Corporation ...