60
BAK
Step 1. Use custom-made RJ45 cable to connect inverter and Lithium battery.
Please take notice for parallel system:
1.
Only support common battery installation.
2.
Use one custom-made RJ45 cable to connect any inverter (no need to connect to a specific inverter) and
Lithium battery.
Simply set battery type of this inverter to “BAK” in LCD program 5. The remaining inverters
are set as “USE”.
3.
Set the DIP address switches to "ON OFF OFF OFF" if it is a single battery. If multiple batteries in parallel,
connect the RJ45 to the master unit's RS485 connector.
Step 2. Press more than three seconds to start Lithium battery, power output ready.
Step 3. Turn on the inverter.
Step 5. Be sure to select battery type as “BAK” in LCD program 5.
If communication between the inverter and battery is successful, the battery icon
on LCD display will