36
AXOR Industries
Service Manual
MiniMagnum
TM
ver.1 rev.05/'15
2.20 Canbus connection
caNBus connection
120
Ohm
1
2
3
J3
J2
J3
J2
MiniMagnum 1
MiniMagnum 2
CAN Server
120
Ohm
CAN H
CAN L
PGND
dc-dc Converter
7
PGND
4
5
6
8
1
2
3
CAN H
CAN L
PGND
dc-dc Converter
7
PGND
4
5
6
8
1
2
1
2
3
dc-dc Converter
PGND
7
4
5
6
8
dc-dc Converter
PGND
3
7
4
5
6
8
PGND
OPTIONAL
Note:
Connect a
ResisToR
(
120 ohm, 1/4w
) between
pins
1
and
2
of the
j2
(or
j3
) connector of the last
minimagnum
TM
.