2.14 Analog and digital outputs connections
DiGital OutPut connection (example)
aNalOG OutPutS connections
MiniMagnum
TM
CN
ANALOG1
CN-GND
5
7
180
470n
ANALOG2
6
180
470n
AN-OUT1
AN-OUT2
M1
AGND
CN
+24VDC
refered to I/O GND
I/O GND
13
14
CN
I/O GND
LOAD
IN1-DIGITAL
CN
25R
LOAD
M1
25R
M1
25R
M1
+24VDC
refered to I/O GND
13
14
13
14
MiniMagnum
TM
MiniMagnum
TM
MiniMagnum
TM
+24VDC
refered to I/O GND
This digital output can be used to send messages from the pre-programmed function of the drive.
For a detailed description of the pre-programmed functions see enclosure "
Speeder One
interface
"
on the CD provided with the drive.
If there is the
m3
connector (OPTIONAL), it provides an additional digital output.
Max. load for each output:
50[mA].
Always use a relay with a diode
in parallel.
They permit visualisation by oscillo-
scope of some of the drive’s meas-
urement values.
The two outputs furnish
+/-10volt
as the low scale setting refers to.
They can be set by the
Speeder One
interface.
Note
: We suggest to connect the shield on both sides: drive side follow the indications illustrated on
paragraph 2.6.