1.1 Description
holdiNg BRaKe
The drive has circuitry that allows the control of the
elec-
tromechanical brake integrated
in the motor, which can
be used with
motor not running, for blocking the motor's
axis
.
The drive supplies the brake with
+24vdc
. It can be
exter-
nally
managed by the user or
automatically
by the drive.
optional
emi
filTeR
The drive is equipped with an integrated
emi anti-distur-
bance filter
at the 3-phase power supply input and with
another EMI anti-disturbance filter at the auxiliary +24V
power supply input.
standard
RegeN ciRcuiT
standard
eXpaNsioN caRds
There is a slot for expansion card to implement additional
features.
optional
safeTy
safeTy
The converter is protected from short circuitry, the Max/Min
Voltage, the drive I
2
t , the Motor I
2
t , etc.
When there is an alarm the "Relè OK" contact opens and the
motor is stopped, or a message is visualised on the display
without compromising the system's functioning.
standard
safeTy eNaBle
fuNcTioN
It is a safety function which avoids the accidental startup of
the motor in the absence of 24Vdc on indicated pin.
optional
Black-Out
DyNamic BRakE
fuNctiON
It stops the motor when there is a black-out.
optional
equipmeNT
a drive serie MiniMagnum
TM
standard
terminals: M1, M2, M4, M5, M6
Service Manual
a CD-ROM with
Speeder One
software interface and all enclosures to service
manual
terminals: M3, M7
optional
Motor inductance, 3x1.2mH, for cables over 20/25 meters in length
an external braking resistor
CBLS cable for motor feedback signal, encoder/resolver (meter multiple)
CBLS power cable for motors series
SuperSAX
motors series
SuperSAX
All
optional
features have to be requested by using the proper ordering code (see "1.5 Product plate
and Ordering code").