5.2
Storage connections
5.2.1
Storage period
Do not store the module for more than six months from the date of manufacture (see type label).
The module must be recharged for longer storage periods.
5.2.2
Physikcal conditions
Store the module in a dry place, protected from solar radiation, maximum 2000 m above sea level.
The following conditions should prevail on an average:
Temperature:
15 … 25 °C
Tough limits:
Storage:
-10 … 50 °C
Transport:
-20 … 60 °C
Relative humidity:
0 … 50 %
No more than 4 Energypack may be stacked on top of each other.
Store Energypack at least 15 cm above the floor to reduce the risk of water damage .
5.2.3
Cleaning
Before storage, remove dust and other deposits from the battery system. Either by vacuuming
and/or with a damp cloth.
6
Packing and transport
The Energypack may only be shipped in suitable packaging that is labelled in accordance with legal
requirements and accompanied by the accompanying documents.
If still available and intact, the delivery packaging can be used.
If not, please contact the manufacturer or the company commissioned by the manufacturer.