AXIS Q6032-C/Q6034-C/Q6035-C Installation Guide
Page 11
ENGL
IS
H
Multi-Connector Cable
The supplied multi-connector cable is required in order to maintain the camera’s IP rating.
Connect the multi-connector cable to the camera’s multi-connector and to the
connectors in the supplied media converter switch, see illustrations on page
page 6 and page 8. The cable provides the following signals:
• DC power
• Network (Ethernet 10/100Base-T)
• I/O
Function
Pin
Wire
Notes
Specifications
Configurable
(Input or
Output)
2, 7 Blue, yellow
Digital input – Connect to GND to activate, or
leave floating (unconnected) to deactivate.
0 to +30 V DC
Digital output – Internal connection to ground
when activated, floating (unconnected) when
deactivated. If used with an external relay, a
diode must be connected in parallel with the
load, for protection against voltage transients.
Max load =100 mA
Max voltage =
+30 V DC
RX+
3
Green/white
Ethernet – receiving
RX-
4
Green
Ethernet – receiving
TX+
5
Orange/white
Ethernet – transmitting
TX-
6
Orange
Ethernet – transmitting
GND
8
Black
Ground
12 V Power
1, 9 Red
Used to power camera
12 - 13.2 V DC
Max load = 6 A
1
8
2
7
9
3
6
4
5