Page 16
AXIS Q6032-C/Q6034-C/Q6035-C Installation Guide
4. Strip the multi-connector cable. Make sure all three shields are intact.
5. Connect the network and I/O wires to the internal network and I/O connectors; open the lid,
insert the wires and close, see the illustration and table above for proper wiring.
6. Connect the ground and power wires to the power connector (DC output), see the illustration
and table above for proper wiring.
1
2
3
4
5
6
7
8
9
Shield
1
Red
Power
2
Blue
Digital Input
3
Green/white
Ethernet
4
Green
Ethernet
5
Orange/white
Ethernet
6
Orange
Ethernet
7
Yellow
Digital Output
8
Black
Ground
9
Red
Power
Shield (2x)
15 mm (0.6”)
10 mm (0.4”)
1
2
3
4
5
6
7
8
9
I/O connector
Ethernet connector
Ethernet connector
Power connector
Shield
Clamp
(DC output)
(internal)
(internal)
(internal)