23
“T
HE
R
ESET
L
OGIC IS
A
CTIVE
”
If the following message comes up
“The Reset Logic Is Active” (Figure 42) the best way to
diagnose is the Diagnostic Tab as per Figure 43. If the E-stop function is highlighted green, it
means one of the conditions of section 5.1 SAFETY ENCLOSURE OPERATION
CONDITIONS are not met.
If confirmed all conditions are met, please review the next section (6 STEP 5
– DOOR
INTERLOCK ALIGNMENT)
Figure 42 The Reset Logic is Active
Figure 43 Diagnostics Screen UCCNC