22
5 S
TEP
4
–
S
AFETY
E
NCLOSURE OPERATION
S
AFETY
E
NCLOSURE
O
PERATION
C
ONDITIONS
When using the Safety Enclosure, the following conditions must be met for operation of the
Axiom CNC machine:
1. All doors must be closed
2. All E-stops keyed or none keyed must be reset (Pulled out)
3. Axiom Controller powered on
4. STEP 1 SET UP THE NETWORK complete as per Axiom Machine user manual
5. STEP 2 INSTALL THE UCCNC SOFTWARE as per Axiom Machine user manual
6. STEP 3 UCCNC LICENSE AND PROFILE INSTALLER complete as per the Axiom
Machine user manual with correct machine profile (Profile: Ax+)
7. Click on the UCCNC Machine Profile shortcut on your desktop (Profile:
Ax+)
8. Hit the reset button (it should be flashing yellow and red). Once clicked it should remain
solid red in colour. You should now be able to control the machine with your UCCNC
software.
Figure 40: Reset button on UCCNC front panel
9. If all conditions are met it will be indicated by the green LED on from of the main
enclosure controller as per Figure 41
Figure 41 Machine Active Green LED