TANKO®-CP Jet Cleaner
7 Maintenance Translation of the original operating/installation instructions 2016/10
49/77
7.4.1.2
CP3 maintenance interval
A
Media connection [MC] / Process connection [PA]
B Plain bearings between shaft and inflow disk
C Plain bearings between shaft and housing
D Cleaning head /shaft connection
E Spray holes in the cleaning head
Picture 7.4-2: CP3 Maintenance Points
The tightening torque values for the thread connections required for maintenance are listed in
section 7.5 Spare Parts and Customer Service
P
oint
Inspection and Maintenance Work
Inter
va
l
M
etho
d
A
The fluid and process connection is implemented using a threaded
connection.
Vibrations from operation could under certain circumstances cause the
thread connection to become loose.
You must that the connection is firmly in place regularly.
m
V, F
B
Check plain bearing to make sure it is fully functional and for wear.
Clean or replace the plain bearing washers as necessary.
300 h
O
V, F,
C
C
Check plain bearing to make sure it is fully functional and for wear.
Clean or replace the plain bearing washers as necessary.
300 h
O
V, F,
C
D
Check the cotter pin for wear.
After 2 years of normal operation, replace the cotter pin.
½ y
V, M
E
Check the drilled holes in the cleaning head for soiling and blockages. Clean
the cleaning head as necessary.
m
V, F
F
Check the thread connection between the housing and the bottom section of
the housing is firmly tightened.
m
V, F
Table 7.4-2: CP3 inspection and maintenance work