AVL DiTEST HV Safety 2000
Technical data
User manual
7-5
7.3.3 High-voltage insulation measurement
Danger of death from electrical voltage
Overvoltage categories CAT-II 600V / CAT-III 300V
The AVL DiTEST HV Safety 2000 fulfils impulse voltage values as per the overvoltage category
CAT-II 600V / CAT-III 300V.
Measurements in electric circuits that are connected directly to the mains are not permitted!
For this reason use the AVL DiTEST HV Safety 2000 only for measurements on the vehicle.
High-voltage
insulation
measurement
Range:
Resolution: Tolerances:
1 - 10M
Ω
10 kΩ
± 1,5 % v. M.
1
10 - 100M
Ω
10 kΩ
± 1,5 % v. M..
1
0,1 - 0,5 G
Ω
10 kΩ
± 3 % v. M..
1
0,5 - 1 G
Ω
10 kΩ
± 5 % v. M..
1
Test voltage:
250 V to 1,000 V adjustable in 16 increments
Nominal test current:
1 mA
1. of the measured value
7.3.4 Equipotential bonding check
Danger of death from electrical voltage
Overvoltage categories CAT-II 600V / CAT-III 300V
The AVL DiTEST HV Safety 2000 fulfils impulse voltage values as per the overvoltage category
CAT-II 600V / CAT-III 300V.
Measurements in electric circuits that are connected directly to the mains are not permitted!
For this reason use the AVL DiTEST HV Safety 2000 only for measurements on the vehicle.
Equipotential bonding check
Range
:
Resolution
:
Tolerances
:
1 mΩ
± 3,5 % v. M.
1
Measuring currents
100 … 1000 mA
1. of the measured value
DANGER
DANGER
Summary of Contents for DITEST HV SAFETY 2000
Page 18: ...General AVL DiTEST HV Safety 2000 1 8 User manual ...
Page 44: ...Troubleshooting AVL DiTEST HV Safety 2000 4 4 User manual ...
Page 46: ...Maintenance and care AVL DiTEST HV Safety 2000 5 2 User manual ...
Page 48: ...Warranty AVL DiTEST HV Safety 2000 6 2 User manual ...
Page 56: ...Technical data AVL DiTEST HV Safety 2000 7 8 User manual ...
Page 58: ...Index AVL DiTEST HV Safety 2000 8 2 User manual ...