Performing a measurement
AVL DiTEST HV Safety 2000
3-4
User manual
3.3
DC voltage measurement
The “
DC voltage measurement
” mode is used to measure voltage.
1.
When you click on the
DC voltage measurement
mode (see Fig. 3-1), a screen of safety
instructions will appear.
You must read and observe these safety instructions.
2.
Click on
F8 Next
.
3.
The AVL DiTEST HV Safety 2000
safety test
is carried out:
- Connect the probe tips briefly
- Press and hold the test button on the red test adapter until the safety test has completed
- The result of the safety test is displayed
4.
Place the probe tips on the test object.
5.
Press and hold the test button on the red test adapter until a stable measured value is
displayed.
6.
The result of the measurement is displayed, see Fig. 3-3 .
(If the test button is not kept pressed for long enough, the following message will appear:
“
Measurement invalid: Test button released too early
”.
If this happens, start a new measurement.
Press and hold the test button on the red test adapter until a stable measured value is
displayed.
Fig. 3-3
Summary of Contents for DITEST HV SAFETY 2000
Page 18: ...General AVL DiTEST HV Safety 2000 1 8 User manual ...
Page 44: ...Troubleshooting AVL DiTEST HV Safety 2000 4 4 User manual ...
Page 46: ...Maintenance and care AVL DiTEST HV Safety 2000 5 2 User manual ...
Page 48: ...Warranty AVL DiTEST HV Safety 2000 6 2 User manual ...
Page 56: ...Technical data AVL DiTEST HV Safety 2000 7 8 User manual ...
Page 58: ...Index AVL DiTEST HV Safety 2000 8 2 User manual ...