70
2
Avitech ASCII Protocol
The MCC-8001U supports the ASCII command prompt interface. You can use
HyperTerminal to control your MCC-8001U. The serial port (
RS-232
) on the
MCC-8001U can also be used to interface with a third-party controller for
control over RS-232. This chapter familiarizes you with using the Avitech
ASCII Protocol (AAP) of the MCC-8001U via Microsoft
®
Windows
®
HyperTerminal function as an example.
2.1
Setting the RS-232 Port
Before using the ASCII Z command interface, make sure that the COM A
(RS-232) port on the MCC-8001U is set at Normal (8-bit data, 1 stop bit, no
parity, and no flow control). The default baud rate is 115200 bps (should be set at
57600 bps). To correctly use the ASCII Z commands, use the Phoenix-G
software’s default Group and Module Number for the MCC-8001U.