45
NOTE:
The RJ-50-to-GPI terminal block adapter has eight positions that can each be used for
setting tally and loading presets.
By default, the terminal block is used to turn on / off the tally for each window:
– Position 1 + GND = turns on main tally for window 1.
– Position 2 + GND = turns on secondary tally for window 1.
– Position 3 + GND = turns on main tally for window 2.
– Position 4 + GND = turns on secondary tally for window 2.
– Position 5 + GND = turns on main tally for window 3.
– Position 6 + GND = turns on secondary tally for window 3.
– Position 7 + GND = turns on main tally for window 4.
– Position 8 + GND = turns on secondary tally for window 4.
Make sure that the RJ-50 GPI terminal block is inserted into the
GPI
port on
the rear panel. The sample pictures below illustrate tapping the wire on
position 1 to turn on the main tally for window 1.
Frame Lock
This allows you to turn on (with checkmark) or off the output display to be
synchronized with the input source. When frame lock is enabled, the
modules help maintain image continuity to create a virtual canvas. Click on
the item to toggle between on / off.
Summary of Contents for MCC-8001U
Page 1: ...User s Manual MCC 8001U Revision 1 3 2 May 2012 ...
Page 12: ......
Page 28: ...16 Settings Menu ...
Page 60: ...48 Click Save The next screen shows the text file opened using Notepad Help Menu ...
Page 74: ...62 To save to flash perform the following steps 1 Click Save File in the Option window ...
Page 76: ...64 2 Click Save File in the Option window ...
Page 78: ...66 Loading File 1 In the Option menu click Load File ...
Page 79: ...67 2 Select a saved file and then click OK to load the preset ...
Page 80: ...68 Making Adjustments 1 In the Option menu click Adjustment ...