![Avidyne Entegra EX5000 Installation Manual Download Page 89](http://html.mh-extra.com/html/avidyne/entegra-ex5000/entegra-ex5000_installation-manual_3031518089.webp)
EX5000 Release 8.2.2 Installation Manual P/N 600-00073-001 Rev 02
- 89 -
RTCA/DO-160E Environmental Qualification Form
NOMENCLATURE: MFD
PART NO:
700-00030-005/805
MANUFACTURER: AVIDYNE CORPORATION
ADDRESS:
4 Middlesex Green - Suite 221, 561 Virginia Road, Concord MA 01742
Table 28:
RTCA/DO-160E Environmental Qualification Form Part No. 700-00030-()
Environmental Tests
RTCA/DO-160E
Section
Test Category
Temperature and Altitude
l
Low Temp
4.5.1
Equipment qualified to Category D1
l
High Temp
4.5.2 & 4.5.3
Equipment qualified to Category D1
l
In-Flight Loss of Cooling
4.5.4
Equipment qualified to Category V
l
Altitude
4.6.1
Equipment qualified to Category D1
l
Decompression
4.6.2
Equipment qualified to Category D1
l
Overpressure
4.6.3
Equipment qualified to Category D1
Temperature Variation
5
Equipment qualified to Category B
Humidity
6
Equipment qualified to Category A
Operational Shocks
7.2
Equipment qualified to Category B
Crash Safety
7.3
Equipment qualified to Category B
Vibration
8
Equipment qualified to Category S, Curve M
Explosive Proofness
9
Category X, no test performed
Waterproofness
10
Category X, no test performed
Fluids Susceptibility
11
Category X, no test performed
Sand and Dust
12
Category X, no test performed
Fungus Resistance
13
Category X, no test performed
Salt Spray
14
Category X, no test performed
Magnetic Effects
15
Equipment qualified to Category Z
Power Input
16
Equipment qualified to Category B
Voltage Spike
17
Equipment qualified to Category A
Audio Frequency Conducted Susceptibility
18
Equipment qualified to Category Z
Induced Signal Susceptibility
19
Equipment qualified to Category AC
Radio Frequency Susceptibility
20
Equipment qualified to Category D
(Conducted) / Z (Radiated)
Emission of Radio Frequency Energy
21
Equipment qualified to Category M
Lightning Induced Transient Susceptibility
22
Equipment qualified to A3E3X (Signal Inputs),
A4E4X (Power Input)
Lightning Direct Effects
23
Category X, no test performed
Icing
24
Category X, no test performed
Electrostatic Discharge
25
Equipment qualified to Category A
Fire/Flammability
26
Category X, no test performed