EX5000 Release 8.2.2 Installation Manual
- 54 -
5.9 TAWS Setup (Optional)
The MFD can interface to the Honeywell Bendix/King EGPWS systems with Phase 2 or later
software.
5.9.1 TAWS Setup
To configure the TAWS interface:
1.
From the Maintenance Mode Page, select TAWS Setup. The TAWS Setup Page displays:
Figure 20: TAWS Sensor Setup Page
2.
Set the following options:
•
Sensor—
Honeywell EGPWS
•
ARINC 429 Port—
ARINC 429 4 – TAWS Default
•
ARINC 453 Port—
ARINC 453 2 – TAWS Default
•
Altitude Annunciation On—
Select this feature to permit a visual annunciation of GPS
altitude on the TAWS display. If selected, a checkmark displays.
3.
When you are done, press
Save
. Press
Cancel
to exit without saving changes.
4.
Changes do not take effect until the MFD has been restarted. From the Maintenance Mode Page,
press
Restart System
.
TAWS Checkout
To test the TAWS installation:
1.
From the Maintenance Mode Page, select TAWS Setup.
2.
Perform a functional test of the EGPWS system in accordance with manufacturer’s instructions.
See the
MFD Pilot Guide
for display operation.
3.
If the Self Test fails, an error message is generated and displayed on the MFD display. See the
EGPWS System Installation Manua
l for explanations and fault isolation procedures.