ZM201 Indicator User Instructions
19
3.2 General Weighing with Accumulation application
3.2 General Weighing with Accumulation application
This section applies if the Accumulator application is active.
3.2.1 SELECT key default function
In the Accumulator application you can view the Gross, Net, Tare, Gross Total, Net
Total and Transaction Count display values by repeatedly pressing
SELECT
.
When the Gross Total is displayed, both the
GROSS
and
TOTAL
annunciators will be
lit. When the Net Total is displayed, both the
NET
and
TOTAL
annunciators will be lit.
When the Transaction Count is displayed, the
TOTAL
annunciator is lit.
3.2.2 Accumulator operation
The accumulator application can be used to record totals of individual weighments.
Follow these steps:
1.
Press
ZERO
to zero the scale, if necessary …
0
is displayed.
2.
Place item on the scale …
Weight is displayed.
3.
Press
to add weight to the accumulator and to print the selected print
format …
The
annunciator lights briefly.
4.
Remove weight from the scale. Weight must return to inside the gross zero
band before another print and accumulation can be recorded.
5.
Repeat steps
2
through
4
for each weighment you want to accumulate.
If enabled, press and hold
for three seconds to print and/or clear the active
accumulator values. These functions are enabled or disabled in a password protected
menu.
You can use gross or net weighing with the accumulator application as it stores both
gross and net totals. You have one accumulator channel that is active all the time.
Press
SELECT
to toggle through the current values. When annunciators TOTAL &
GROSS are lit this indicates the total for the gross value. When annunciators TOTAL
& NET are lit this indicates the total for the net value. When annunciators TOTAL &
TARE are lit this indicates the total for the tare value. When TOTAL only is lit this is
the current number of transactions.
You can press the
F1
key to add the weight to the accumulator without performing the
print function.