Operators Manual
ALS 330/430
Release 8/07
Page 58
Connections and signals
8.2.3
Signals for the EP applicator
For controlling the applicator the signals air stream, cylinder valve and blow on are necessary.
After a product signal has occurred the labelling cylinder valve is switched active after the delay
STAD. However if at this time the applicator is not in the home position then error message
E__2 is generated. After the delay time APT1 the blow on valve is switched active for the time
APT2.
When APT2 is completed both the labelling cylinder valve and the blow on valve signals are
switched inactive. If the control does not read the home position in the time given - 3* (APT1+
APT2) - than the error message E__2 is generated.
Productstart
Cylinder valve
Dispense label
+ Airstream valve
Blowon valve
Homeswitch
1
2
Missing Label: Labeller not ready for dispense
Error: Applicator not in homeposition
3
Error: Homeposition not detected
STAD
APT1
APT3
APT2
1
3
STAD
STAD
APT1
4 * (APT1 + APT2)
STAD
2
Figure 19 Timing EP applicator
Summary of Contents for ALS 330
Page 1: ...Ausgabe 08 07 Artikelnummer 0089999 06...
Page 2: ......
Page 6: ...Operators Manual ALS 330 430 Release 8 07 Contents...
Page 18: ...Operators Manual ALS 330 430 Release 8 07 Page 16 Description...
Page 37: ...Operators Manual ALS 330 430 Release 8 07 Page 35 Operation...
Page 38: ......
Page 50: ......
Page 79: ...Operators Manual ALS 330 430 Release 8 07 Page 71 Connections and signals...
Page 80: ......
Page 84: ...Operators Manual ALS 330 430 Release 8 07 Page 76 Errors and warnings...
Page 92: ......