Operation
4.2.4 Lead
screw
adjustment
For adjustments of the dispensing edge towards or away from the conveyor, the lead screw
integrated in the labelling head should be used. Positions can be read from the scale on the
dispensing edge bars.
4.2.5
Adjustment of the dispensing edge
Loosen handle 1 and 2 and turn lead screw Z. Once the adjustment is completed pull the
handles tight again.
Figure 13 Dispensing edge
4.2.6 Printer
adjustment
If your labeller is equipped with a printer, you adjust the print position as well with the lead
screw Z. In this case loosen handle (orange) for printer and handle 1. Once the adjustment is
completed, pull the handles tight again.