Serial interface
7.2
Interface commands
The below described commands will change one of the labelling parameter. The values are not
stored and will be lost when turning off power.
If the sequence nnnn is replaced by the character "?" then the current value of that parameter
will be returned by the labelling machine as a 4 character string confirming the name of the
parameter requested followed by 4 numbers representing the current value of that parameter.
The character 04H terminates all return messages.
Example
PC send the message:
#!VELO?
Machine returns:
VELO0300<04H>
Command Description
Range
#!APOSnnnn Value
APOS
-0050 – 0100 mm
#!APPLnnnn
Applicator type
0000 direct dispense
0001 ASA
0002 EP
0003 EP_U
0004 PLUA
0005 INDX
#!APSFnnnn
APSF function
0000 off
0001 on
#!APT1nnnn Applicator
time
0001 – 7500 ms
#!APT2nnnn Applicator
time
0001 – 7500 ms
#!APT3nnnn Applicator
time
0000 – 5000 ms
#!ASTPnnnn Value
ASTP
-0020 – 0050 mm
#!BANKnnnn
Change product bank
0000 - 0009
#!BLOWnnnn
Blow on time = APT 2
0001 - 7500 ms
#!COMPnnnn
Automatic label compensation
0000 = Off
0001 = On
#!CONTnnnn
Material contrast
0001 – 0200
0000 automatically
#!DISTnnnn
Distance label sensor – dispensing
edge
0080 – 9999 * 0.1 mm
#!EGRAnnn Gear
ratio
0300 – 1000
#!LPITnnnn
Label length
0005 – 0999 mm
0000 automatically
#!MACHnnnn
Machine type
0000 ALS230
0001 ALX720
0002 ALS330
0003 ALS430
#!MDIRnnnn
Motor direction
0000 Right --- >
Summary of Contents for ALS 330
Page 1: ...Ausgabe 08 07 Artikelnummer 0089999 06...
Page 2: ......
Page 6: ...Operators Manual ALS 330 430 Release 8 07 Contents...
Page 18: ...Operators Manual ALS 330 430 Release 8 07 Page 16 Description...
Page 37: ...Operators Manual ALS 330 430 Release 8 07 Page 35 Operation...
Page 38: ......
Page 50: ......
Page 79: ...Operators Manual ALS 330 430 Release 8 07 Page 71 Connections and signals...
Page 80: ......
Page 84: ...Operators Manual ALS 330 430 Release 8 07 Page 76 Errors and warnings...
Page 92: ......