Page 61
Connections and signals
8.3.1 Product
sensor
The product sensor starts the labelling. The source of the signal could be a optical sensor, a
switch or a signal from a PLC. The time between start signal and start of dispensing (adjusted
with POS) should be as small as possible. This means that an optical sensor should be placed
10 to 20 mm before the dispensing edge. The minimum distance is necessary for the internal
speed compensation.
The machine is supplied as standard with one socket for connecting the product sensor. You
may either use a NPN or PNP type sensor output.
+24V
GND
13
black
blue
white
red
brown
5
9
4
8
3
7
2
6
1
Signal-
GND
Supply
white
black
blue
26
34
27
CN33
S5-5-C8-30
NPN-Sensor
5
9
4
8
3
7
2
6
1
Figure 22 Example for connecting an NPN sensor (Datalogic)
+24V
GND
13
black
blue
white
red
brown
5
9
4
8
3
7
2
6
1
Signal-
GND
Supply
white
black
blue
26
34
27
CN33
S5-5-C8-30
PNP-Sensor
5
9
4
8
3
7
2
6
1
Figure 23 Example for connecting an PNP sensor (Datalogic)
Summary of Contents for ALS 330
Page 1: ...Ausgabe 08 07 Artikelnummer 0089999 06...
Page 2: ......
Page 6: ...Operators Manual ALS 330 430 Release 8 07 Contents...
Page 18: ...Operators Manual ALS 330 430 Release 8 07 Page 16 Description...
Page 37: ...Operators Manual ALS 330 430 Release 8 07 Page 35 Operation...
Page 38: ......
Page 50: ......
Page 79: ...Operators Manual ALS 330 430 Release 8 07 Page 71 Connections and signals...
Page 80: ......
Page 84: ...Operators Manual ALS 330 430 Release 8 07 Page 76 Errors and warnings...
Page 92: ......