Operators Manual
ALS 330/430
Release 8/07
Page 20
Preparing the machine
3.2.3
Capacitive label sensor
For transparent labels the standard photo label sensor doesn’t work. In this case, use a
mechanic or a capacitive label sensor.
Note:
For correct automatic initialisation, the CONT parameter has to be set to a
manual value, if you using not the standard photo sensor.
A mechanical sensor is limited in the speed. The bounce at the label edges produces wrong
signals.
There is optional a capacitive label sensor available (Leuze GK14/24L).
Adjustment of the sensor is carried out as follows (Figure 5):
1. Set sensitivity to maximum by turning the Potentiometer clockwise. Then rotate ½ turn
anticlockwise.
2. Remove label material out of sensor.
3. Perform base adjustment, that both LED “base adjustment” have the same brightness.
4. Put label with backing paper inside the sensor. Doing this, the LED “switch output” and the
left LED “base adjustment” are switched off. With backing paper only in the sensor both
LED are switched on. If the LED are lightning with label inside the sensor, increase
sensitivity in ¼ turn steps by rotating the sensitivity clockwise.
5. Check the adjustment over the complete length of label.
Carry out the above adjustment after mounting, cleaning or increasing sensitivity.
Figure 5 Capacitive sensor
Summary of Contents for ALS 330
Page 1: ...Ausgabe 08 07 Artikelnummer 0089999 06...
Page 2: ......
Page 6: ...Operators Manual ALS 330 430 Release 8 07 Contents...
Page 18: ...Operators Manual ALS 330 430 Release 8 07 Page 16 Description...
Page 37: ...Operators Manual ALS 330 430 Release 8 07 Page 35 Operation...
Page 38: ......
Page 50: ......
Page 79: ...Operators Manual ALS 330 430 Release 8 07 Page 71 Connections and signals...
Page 80: ......
Page 84: ...Operators Manual ALS 330 430 Release 8 07 Page 76 Errors and warnings...
Page 92: ......