Page 27
Operation
the backing material is clamped in the slot. Wind the mandrel a few times to take up any
backing material slack between the deviator roller and the rewind mandrel.
Figure 11 Rewind
4.2.3
Adjusting the pressure roller
The pressure roller should always be positioned over the middle of the backing material. This
ensures accurate label placement. Turn the pressure roller away from the drive roller. Loosen
both knurled screws. Move the entire unit to its correct position. Fasten the screws securely
again.
Figure 12 Pressure roller
Summary of Contents for ALS 330