11/14 Rev. 03
USER MANUAL
Advanced Applications
AP 4.4 – AP 5.4 – AP 5.6 – AP 7.t – 64-xx – DPM – PEM – ALX 92x
7
Settings in the parameter menu
Further settings for 64-xx Dispenser see user manual 64-xx, topic section „Setup“,
chapter
Settings at 64-xx dispensers
on page 17.
Settings for application of ALX 92x with applicator see service manual ALX 92x,
topic section „Applicator Interface“, chapter
Selecting an applicator type
on page 5.
Setting
Interface
Printer
Parameter
Value
Accept start si-
gnals
--
All
SYSTEM PARAMETER > Exter-
nal signal
Singlestart
Signal source
Singlestart
input
64-xx
--
a
--
64-xx Dispenser,
AP 5.4 Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start
source
Foot switch
AP 5.4, AP 5.6, AP 7.t
--
--
Disp. edge
light barrier
64-xx Dispenser,
AP 5.4Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start
source
Light barrier
USI
64-xx Dispenser
DISPENSER PARA > Start
source
USI interface
64-xx, ALX 92x, ALX 73x
--
--
I/O
AP 5.4, AP 5.6, AP 7.t
--
--
AI
ALX 92x, ALX 73x
--
--
Signal flange
Singlestart
input
64-xx, AP 5.4, AP 7.t,
AP 5.4Gen II, AP 5.6
SYSTEM PARAMETER > Start
print mode
„Pulse rising“
USI
64-xx, ALX 92x
DP INTERFACE > Start print
mode
„Pulse rising“
I/O
AP 5.4, AP 5.6, AP 7.t
I/O BOARD >
Start print mode
„Pulse rising“
AI
ALX 92x, ALX 73x
APPLICATOR PARA > Start
print mode
„Pulse rising“
Start delay
Singlestart
input
AP 5.4Gen II Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start Off-
set
Enter distance
between start
sensor and dis-
pensing edge
USI
64-xx, ALX 92x, ALX 73x
DP INTERFACE > Start delay
I/O
AP 5.4Gen II Dispenser,
AP 5.6 Dispenser
DISPENSER PARA > Start Off-
set
AI
ALX 92x, ALX 73x
APPLICATOR PARA > Start de-
lay
[Tab. 5] Overview on the most important settings for start signal application (Firmware versions 3.52/6.52/7.52).
a) „--“ = No setting required.