3.
Insert the tie rod mounting screws (6, 10) into the P end plates (7b and 8) and
tighten them by two to three turns.
4.
Inspect the correct placement of the valves (1), the separation plate/supply plate
(9) and the sealing components (4, 5).
5.
Insert the upper, third tie rod (2b) with tie rod sleeve (11) into the system.
Check the correct placement of the torsion protection (12).
6.
Evenly tighten the tie rod mounting screws (6, 9) in the P end plates (7b, 8).
Tightening torque: 2 + 0.5 Nm (22.16 + 4.443 in lbs.)
Exchanging valves or separation plate/supply plate
1.
Loosen the tie rod mounting screws (6 and/or 10) by two to three turns.
2.
Remove the upper tie rod (2b).
3.
Pull the valves and/or the separation plate/supply plate apart at the desired
position.
The valve centerings must be keep clear.
4.
Remove the valve and/or the separation plate/supply plate with a radial tilting
movement in the direction of the working connections.
5.
Insert the new valve or the separation plate/supply plate and press lightly
against the valve or plate until it snaps into place.
6.
Inspect the correct placement of the valves (1), the separation plate/supply plate
(9) and the sealing components (4, 5).
7.
Insert the upper, third tie rod (2b) into the system.
Check the correct placement of the torsion protection (12).
8.
Evenly tighten the tie rod mounting screws (6, 9) in the end plates (7a or 7b , 8).
Tightening torque: 2 + 0.5 Nm (22.16 + 4.443 in lbs.)
Expanding the valve system
1.
Loosen the tie rod mounting screws
(6 and/or 10) by two to three turns.
2.
Disassemble the end plate (7a) or P end plate (7b).
3.
Remove the upper tie rod (2b).
4.
Screw the tie rod extensions (3) into the tie rods (2a and 2b) until flush using a
torque of 2.0 + 0.5 Nm (22.16 + 4.443 in lbs.).
NOTICE:
Use a liquid adhesive substance for screws.
5.
Mount the end plate (7a, 7b) on the lower tie rods (2a).
6.
Insert the new valve or the separation plate/supply plate and press lightly
against the valve or plate until it snaps into place.
7.
Inspect the correct placement of the valves (1), the separation plate/supply plate
(9) and the sealing components (4, 5).
8.
Insert the upper, third tie rod (2b) into the system.
Check the correct placement of the torsion protection (12).
9.
Evenly tighten the tie rod mounting screws (6, 9) in the end plates (7a or 7b).
Tightening torque: 2 + 0.5 Nm (22.16 + 4.443 in lbs.).
6
Commissioning and operation
Step-by-step commissioning
Before commissioning the entire system, check each of the individual functions step-
by-step.
1. First check the valves for correct assignment of the control signals.
2. Then check the pneumatic functions.
3. Only commission the entire system after following the above steps.
7
Service and maintenance
The TC08/TC15 valve terminal system is maintenance-free.
NOTICE
Commissioning may only be carried out by qualified electrical or pneumatic
personnel or an instructed person under the direction and supervision of qualified
personnel (see also “Personnel qualifications”).
WARNING
Risk of uncontrolled actuator movements when the pneumatics are switched
on!
There is a danger of personnel injury if the system is in an undefined state.
O
Put the system in a defined state before switching it on.
CAUTION
Damage to the surface caused by solvents and aggressive detergents!
The surfaces and seals could be damaged by aggressive solvents and cleaning
agents.
O
Never use solvents or aggressive detergents.
O
Comply with the maintenance intervals and specifications for the entire system.
8
Spare parts and accessories
9
Disposal
Dispose of the TC08/TC15 valve system and its components in accordance with the
currently applicable regulations in your country.
10 Technical data
W
Valves for the TC08 or TC15
1)
1) The respective version and material numbers as well as further accessories approved for
your configuration can be found in the online catalog
(www.aventics.com/pneumatics-catalog).
W
Separation plates/supply plates
1)
W
Tie rod extensions
1)
Dimensions
Vary according to model and
configuration; see the documentation
“Modular Valve Systems, TC Series,
Technical Data.”
Weight
Operating voltage
Working pressure
-0.9 to 10 bar
Nominal flow
700/800 l/min (TC08)
1300/1500 l/min (TC15)
Temperature rangefor application
-10 °C to 50 °C
Type
Spool valve
1)
1) Zero overlap
Permissible medium
Compressed air, lubricated
(0 mg/m
3
–5 mg/m
3
)
or non-lubricated
Degree of protection according to
EN 60529/IEC 529
IP65
Mounting position
Any
For further technical data, please see the online catalog at
www.aventics.com/pneumatics-catalog.
AVENTICS
| TC08/TC15 |
R412006551–BAL–001–AD
| English
4