AVENTICS
| RTC-CG and HD | R402005942–BDL–001–AB | English
7
8
Startup
WARNING
Danger due to uncontrollable acceleration of the slide!
If the rodless cylinder is not pressurized uniformly on
both sides, the slide can accelerate uncontrollably and
break through an end stop with high kinetic energy. This
can cause serious injury or even death.
O
Ensure that the rodless cylinder is always
pressurized on both sides.
O
Ensure that the pressure on both sides of the
rodless cylinder is balanced.
O
Ensure that no persons are in the area of the end
stops.
CAUTION
Danger due to loose objects in the travel range of the
slide!
Due to its movement energy, the slide can carry objects
away with it that are in the travel range or protrude into
the travel range.
O
Ensure that no loose components, tools, or
workpieces, which can be carried away by the slide,
are in the travel range of the slide.
Carrying out a test run
After the system has been adjusted, a test run can be
carried out.
1.
First, carry out a test run without components and
without useful load.
2.
Adjust the intermediate stop as necessary by shifting
the adjustment plate in the clamping plate profile. In
order to do this, loosen the screws on the T-groove
nuts and then tighten them again. Note the tightening
torque under “6 Assembly”.
3.
Finally, carry out a test run with a useful load.
CAUTION
Danger due to slide movement!
Due to its kinetic energy, the slide can crush limbs and
cause other injuries.
O
Ensure that persons do not reach into the movement
range of the rodless cylinder.
Control example
5/3
A
P1
P2
P3
P4
B
R
P
R
A
B
R
5/2
R