Assembly
AVENTICS
| PROFINET-IO | R412015162–BDL–001–AE
79
English
5.3.1
General notes on connecting the bus coupler
Use pre-assembled plug connections to connect
the modules.
O
Observe the pin assignment in Table 79 if you do not use
pre-assembled plug connections and cables.
The connection technology and plug assignment comply
with the PROFINET-IO specifications.
2
1
4
3
4
3
4
3
2
1
2
1
BUS
X71
BUS
X72
Table 5:
Pin assignments X71 (BUS), 4-pin, D-coded
Pin
Signal
Meaning
1
TD+
Transmit/(receive)
2
RD+
Receive/(transmit)
3
TD-
Transmit/(receive)
4
RD-
Receive/(transmit)
Housing
Shield
Shield, protective grounding
Table 6:
Pin assignments X72 (BUS), 4-pin, D-coded
Pin
Signal
Meaning
1
TD+
Transmit/(receive)
2
RD+
Receive/(transmit)
3
TD-
Transmit/(receive)
4
RD-
Receive/(transmit)
Housing
Shield
Shield, protective grounding