Assembly
86
AVENTICS
| PROFINET-IO | R412015162–BDL–001–AE
5.3.8
FE connection
O
To discharge EMC interferences, connect the FE
connection (
2
) on the left EP end plate of the VS via a low-
impedance line with a functional grounding.
Recommended cable cross-section: 10 mm
2
.
With an HF04-/HF04XF valve block, connect the FE connection (
1
)
on the valve block to the functional grounding via a low-
impedance line.
5.4
PROFINET-IO fieldbus interface
The bus coupler can be operated on a PROFINET-IO fieldbus
with real-time classes RT and IRT.
2
1
4
3
PO WE R
X10
Table 15:
Load supply assignment for 8x output module, 8DO, M12x1,
A-coded
Pin
X10
Assignment
1
Free
GND reference for power supply 2
2
0x
24 V supply voltage 1 for outputs O0 to O3
3
GND
GND reference for power supply 1
4
24 V supply voltage 2 for outputs O4 to O7
2
NOTICE
Total current is too high
Every output is supplied with a continuous current of max. 0.5 A.
Current loads over 0.5 A per output can damage the system.
O
Make sure that the current load of 0.5 A per output is not
exceeded.
1
Type
Ethernet
Potential separation
Yes
Station address
Any in acc. with RFC specifications
Baud rate
100 MBaud
Summary of Contents for PROFINET-IO
Page 2: ......
Page 114: ...Disposal 114 AVENTICS PROFINET IO R412015162 BDL 001 AE...
Page 174: ...Elimination des d chets 174 AVENTICS PROFINET IO R412015162 BDL 001 AE...
Page 236: ...ndice 236 AVENTICS PROFINET IO R412015162 BDL 001 AE...
Page 347: ...Nyckelordsregister AVENTICS PROFINET IO R412015162 BDL 001 AE 347 Svenska...