Commissioning and Operation
AVENTICS
| PROFINET-IO | R412015162–BDL–001–AE
93
English
6.1.3
Switching the tolerance level for valve supply
U
Q1
and U
Q2
The threshold 20.4 V and 21.6 V can be adjusted for different
valve series. In the delivery condition, the threshold (see
Table 19 on page 92) is set to 21.6 V (10%) (S 3.7 and S 3.8 set
to ON). If the supply voltage for the valve control drops below
this threshold, a diagnostic message will be generated.
6.1.4
Diagnosis
The diagnosis can be read using the module states.
Table 20:
Coding of the single-bit diagnosis of the valve driver
Byte
Valve slot
Diagnostic bit
Short circuit or open load in valve solenoid
0
1
D0.0
A (14)
D0.1
B (12)
2
D0.2
A (14)
D0.3
B (12)
3
D0.4
A (14)
D0.5
B (12)
4
D0.6
A (14)
D0.7
B (12)
1
5
D1.0
A (14)
D1.1
B (12)
6
D1.2
A (14)
D1.3
B (12)
7
D1.4
A (14)
D1.5
B (12)
8
D1.6
A (14)
D1.7
B (12)