For G350 and G700 Media Gateways:

For all media gateways:

If the terminal equipment (for example, the media server or media 
gateway) causes harm to the telephone network, the telephone 
company will notify you in advance that temporary discontinuance of 
service may be required. But if advance notice is not practical, the 
telephone company will notify the customer as soon as possible. Also, 
you will be advised of your right to file a complaint with the FCC if 
you believe it is necessary.

The telephone company may make changes in its facilities, equipment, 
operations or procedures that could affect the operation of the 
equipment. If this happens, the telephone company will provide 
advance notice in order for you to make necessary modifications to 
maintain uninterrupted service.

If trouble is experienced with this equipment, for repair or warranty 
information, please contact the Technical Service Center at
1-800-242- 2121 or contact your local Avaya representative. If the 
equipment is causing harm to the telephone network, the telephone 
company may request that you disconnect the equipment until the 
problem is resolved.

A plug and jack used to connect this equipment to the premises wiring 
and telephone network must comply with the applicable FCC Part 68 
rules and requirements adopted by the ACTA. A compliant telephone 
cord and modular plug is provided with this product. It is designed to 
be connected to a compatible modular jack that is also compliant. It is 
recommended that repairs be performed by Avaya certified 
technicians.

The equipment cannot be used on public coin phone service provided 
by the telephone company. Connection to party line service is subject 
to state tariffs. Contact the state public utility commission, public 
service commission or corporation commission for information.

This equipment, if it uses a telephone receiver, is hearing aid 
compatible.

Canadian Department of Communications (DOC) Interference 
Information

This Class A digital apparatus complies with Canadian ICES-003.

Cet appareil numérique de la classe A est conforme à la norme
NMB-003 du Canada.

This equipment meets the applicable Industry Canada Terminal 
Equipment Technical Specifications. This is confirmed by the 
registration number. The abbreviation, IC, before the registration 
number signifies that registration was performed based on a 
Declaration of Conformity indicating that Industry Canada technical 
specifications were met. It does not imply that Industry Canada 
approved the equipment.

Declarations of Conformity

United States FCC Part 68 Supplier’s Declaration of Conformity 
(SDoC)

Avaya Inc. in the United States of America hereby certifies that the 
equipment described in this document and bearing a TIA TSB-168 
label identification number complies with the FCC’s Rules and 
Regulations 47 CFR Part 68, and the Administrative Council on 
Terminal Attachments (ACTA) adopted technical criteria.

Avaya further asserts that Avaya handset-equipped terminal 
equipment described in this document complies with Paragraph 
68.316 of the FCC Rules and Regulations defining Hearing Aid 
Compatibility and is deemed compatible with hearing aids.

Copies of SDoCs signed by the Responsible Party in the U. S. can be 
obtained by contacting your local sales representative and are 
available on the following Web site: 

http://www.avaya.com/support

.

All Avaya media servers and media gateways are compliant with FCC 
Part 68, but many have been registered with the FCC before the SDoC 
process was available. A list of all Avaya registered products may be 
found at: 

http://www.part68.org 

by conducting a search using “Avaya” 

as manufacturer.

European Union Declarations of Conformity

Avaya Inc. declares that the equipment specified in this document 
bearing the “CE” (Conformité Europeénne) mark conforms to the 
European Union Radio and Telecommunications Terminal Equipment 
Directive (1999/5/EC), including the Electromagnetic Compatibility 
Directive (89/336/EEC) and Low Voltage Directive (73/23/EEC). This 
equipment has been certified to meet CTR3 Basic Rate Interface (BRI) 
and CTR4 Primary Rate Interface (PRI) and subsets thereof in CTR12 
and CTR13, as applicable.

Copies of these Declarations of Conformity (DoCs) can be obtained 
by contacting your local sales representative and are available on the 
following Web site: 

http://www.avaya.com/support

.

Japan

This is a Class A product based on the standard of the Voluntary 
Control Council for Interference by Information Technology 
Equipment (VCCI). If this equipment is used in a domestic 
environment, radio disturbance may occur, in which case, the user 
may be required to take corrective actions.

To order copies of this and other documents:

Call:

Avaya Publications Center
Voice 1.800.457.1235 or 1.207.866.6701
FAX 1.800.457.1764 or 1.207.626.7269

Write:

Globalware Solutions
200 Ward Hill Avenue
Haverhill, MA 01835 USA
Attention: Avaya Account Management

E-mail:

[email protected]

For the most current versions of documentation, go to the Avaya 
support Web site: 

http://www.avaya.com/support

.

Manufacturer’s Port
Identifier

FIC Code

SOC/REN/
A.S. Code

Network 
Jacks

Ground Start CO trunk

02GS2

1.0A

RJ11C

DID trunk

02RV2-T

AS.0

RJ11C

Loop Start CO trunk

02LS2

0.5A

RJ11C

1.544 digital interface

04DU9-BN

6.0Y

RJ48C

04DU9-DN

6.0Y

RJ48C

04DU9-IKN

6.0Y

RJ48C

04DU9-ISN

6.0Y

RJ48C

Basic Rate Interface

02IS5

6.0F

RJ49C

Summary of Contents for S8100 Series

Page 1: ...Job Aids for Upgrading the Avaya S8100 Media Server with the Avaya G600 or Avaya CMC1 Media Gateway 555 245 751 Issue 1 November 2003...

Page 2: ...ntly innocuous tampering Harm such as harmful tampering data loss or alteration regardless of motive or intent Be aware that there may be a risk of unauthorized intrusions associated with your system...

Page 3: ...th Part 68 of the FCC rules On either the rear or inside the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number RE...

Page 4: ...ation of Conformity SDoC Avaya Inc in the United States of America hereby certifies that the equipment described in this document and bearing a TIA TSB 168 label identification number complies with th...

Page 5: ...rver to upgrade its software from R9 5 This Job Aid provides the steps for upgrading an S8100 Media Server s software by transferring the new software from a CD This procedure applies to either a full...

Page 6: ...8100 s Processor board a Connect a cable from the laptop s PCMCIA Ethernet card to an RJ45 coupler b Connect a cross over flip cable from the coupler to the TN2314 s RJ45 jack 4 LT IE Connect to the S...

Page 7: ...e entire backup a Click Administer System b Log in with lucent3 c Click Backup Restore under System Maintenance d Click Immediate Backup e Under Choose Items for Immediate Backup select everything tha...

Page 8: ...apter 2 and Appendix I of Installation and Upgrades for the S8100 Media Server 555 123 146 a On the S8100 s desktop right click My Network Places and select Search b When the search window pops up cli...

Page 9: ...dows 2000 appears when the upgrade to SP4 finishes choose no to decline f From the bash shell do a manual reboot by executing start all 19 If you upgraded to SP4 in Step 18 and restarted Windows 2000...

Page 10: ...tip to display the customer s parameters If any parameter is not as you recorded in Step 15 use the following setip commands to reset those parameters setip name args setip cust args setip dns args se...

Page 11: ...12 you must do two restores After the first restore repeat the steps above using the location of the backed up AUDIX announcements for the Source in Step d 39 SDT IE Close Internet Explorer 40 SDT Ope...

Page 12: ...eed to close 56 BS Close the bash windows a Type exit to close the bash window b Type exit to close the LAC window 57 LT IE Backup the translations and other data to the PCMCIA card or to a network lo...

Page 13: ...software release on the new hard drive is earlier than the software release on the hard drive to be replaced you must upgrade the software on the new hard drive after the replacement Access keys The a...

Page 14: ...00 s Processor board a Connect a cable from the laptop s PCMCIA Ethernet card to an RJ45 coupler b Connect a cross over flip cable from the coupler to the TN2314 s RJ45 jack 4 LT IE Connect to the S81...

Page 15: ...ntire backup a Click Administer System b Log in with lucent3 c Click Backup Restore under System Maintenance d Click Immediate Backup e Under Choose Items for Immediate Backup select everything that i...

Page 16: ...e always installed in the top slot of the drive bay 20 Re install the Processor board into the platform and power up the system 21 Wait approximately 5 minutes then reconnect to the S8100 s desktop an...

Page 17: ...Gateways 555 233 146 30 LAC Exit the LAC window and bash shell a Type exit and close the telnet window b Type exit to close the bash window 31 SDT Open Internet Explorer on the S8100 s desktop and lo...

Page 18: ...arms are present Run display alarms 44 SAT Verify outgoing alarm reports link to INADS Run test inads link 45 SAT Verify no license emergency numbers Type change system parameters features See Adminis...

Page 19: ...se Items for Immediate Backup select everything that is installed e Set Destination to PCMCIA or click Other Location to backup to a network location f Click the Backup button Note If the medium you a...

Page 20: ...laces the TN795 with the TN2314 processor circuit pack The hard drive on the new circuit pack contains the new software Access keys The access method for each step is identified by the following keys...

Page 21: ...proxy server radio button and click OK to close the popup windows 3 Connect the laptop to the R9 5 Processor board TN795 a Connect a cable from the laptop s PCMCIA Ethernet card to an RJ45 coupler b...

Page 22: ...nnouncements and MultiVantage translations When the backup finishes return to the Immediate Backup screen and select only the AUDIX announcements radio button and send this backup to the same or a dif...

Page 23: ...to xxx under Remote Control Terminal Services where xxx is the host name used for this system c If a VBScript error message appears click OK d Click the Connect button leave the Server field blank e...

Page 24: ...the LAC window and bash shell a Type exit and close the telnet window b Type exit to close the bash window 32 SDT Open Internet Explorer on the S8100 s desktop and login a Double click the IE icon on...

Page 25: ...Run display alarms 45 SAT Verify outgoing alarm reports link to INADS Run test inads link 46 SAT Verify no license emergency numbers Type change system parameters features See Administer No License E...

Page 26: ...Under Choose Items for Immediate Backup select everything that is installed e Set Destination to PCMCIA or click Other Location to backup to a network location f Click the Backup button Note If the me...