background image

IP403 Office Platform 

IP403 Office - Front View - Page 15 

IP403 Office - Front View 

Yellow LEDs 

LEDs 1-3 = Expansion Ports 1-3 status 
LEDs 4-7 = ISDN 1-4 status 
LED 8 = WAN status 

Green LEDs 

Terminal connected

 

DT 

or

 DS Ports 1-8

 

Unit Status LED

Red = Alive but not initiated

 

Green = Running OK

 

Phone Ports 1& 2 

(POTs)

LAN Ports 1-8

 

Port 8 

(Cascade port) 

Yellow LED 

LAN Collision

 

Green LED 

Solid Green LED - LAN OK 
Flashing Green - LAN OK and active

Yellow LED

On - 100Mbps operation
0ff - 10Mbps operation

 

Cascade Switch

For port eight

 

Port connections 

• 

DT/DS Ports

 

DT ports are for connection to Avaya 2000 series telephones (see page 5). 

DS ports are for connection to Avaya 4400 and/or 6400 series telephones (see page 5). 

  At default DT ports are set to A-Law PCM encoding and DS ports to either A-Law or  
 

µ

-Law PCM encoding (see page 32). However, both ports can be switched in software -  

  refer to the Administration Manager Manual for details). 

Using DT Line Cords (see page 56) and standard structured wiring, these RJ45 ports can be 

extended to the required telephone location. In addition, converters can be used to provide BT 

New Plan sockets (431A/631A) if required (see page 65). When telephones are equipped with 

line cords that terminate in RJ11 plugs, then pin-to-pin RJ11/RJ45 adapters should be used. 

• 

Plain Ordinary Telephone (POTS) Ports 

These two ports are used for connection to standard analog telephones, fax machines and 

modems. Using standard structured wiring, these RJ45 ports can be extended to the required 

telephone location. Converters can be used to provide BT New Plan sockets (431A/631A) if 

required (see page 65). When devices are equipped with line cords that terminate in RJ11 plugs, 

then pin-to-pin RJ11/RJ45 adapters should be used. 

• 

LAN Ports 

The eight auto-negotiating 10/100 BaseT LAN hub ports are used for PC and server connectivity. 

They can also be used to connect to the optional IP400 WAN3 Expansion Module (see page 30) 

and IP telephones. LAN ports allow information relating to incoming and outgoing telephone calls 

to be forwarded to PC based applications. They also provide access to the router 

functionality/configuration of the IP403 Office platform for both data and Voice over IP (VoIP) 

calls. (Where IP telephony is required, a suitable switch, i.e. an Avaya Cajun P130, should be 

used.) This eight port auto-negotiating 10/100 BaseT LAN hub has a single MAC address (printed 

on the base of the unit). 

  Where more than eight LAN connections are required, the eighth LAN port can be used for 

cascading to other hubs. The 

Cascade 

pushbutton to the right of this port is used to set the 

mode. When the 

Cascade 

switch is in the 

out 

position the port can be connected to another hub 

without the need for a crossover cable, i.e. the port is an MDI type port. When the 

Cascade 

switch is in the 

in

 position the port can be connected directly to a PC. 

 

Cables 

IP403 Office DT PRI 30 E1 & DS PRI 24 T1 are supplied with one red ISDN cable. IP403 Office DT 

BRI 8 & DS Analog 4 are supplied with four red ISDN cables. For Port Pinouts and Cables, refer to 

pages 51 and 55 respectively. 

IP Office Installation Manual 

IP403 Office Platform - Page 15 

40DHB0002USCL – Issue 7 (09/25/2002) 

 IP403 Office - Front View 

Summary of Contents for IP OFFICE 40DHB0002USCL

Page 1: ...IP Office Installation Manual 40DHB0002USCL Issue 7 09 25 2002 ...

Page 2: ...n New Zealand 9 IP Office Operation in USA 9 IP401 Compact Office Platform 10 General 10 IP401 Compact Office Front View 11 Port connections 11 IP401 Compact Office Rear View 12 Port connections 12 Typical Configuration 13 IP403 Office Platform 14 General 14 Expansion Modules 14 Integral Modules 14 IP403 Office Front View 15 Port connections 15 IP403 Office Rear View 16 Port connections 16 Typical...

Page 3: ...ce Rack Mounting Kits 34 Expansion Modules 34 Preparing for Installation 35 Introduction 35 Tools Parts Required 35 Space requirements 35 Environmental requirements 36 Power Supply requirements 36 Grounding 37 Protective Ground 37 Functional Ground 37 Installing a New System 38 Unpacking 38 Initial Assembly 38 Installation of Integral Modules 39 Rack Mounting Assembly Instructions 42 IP401 Compact...

Page 4: ... DTE Port 25 Way or 9 Way D Type socket 52 Audio Port 3 5mm Stereo Jack Socket 53 Expansion Port RJ45 Socket 53 External Control Port 3 5mm Stereo Jack Socket 53 WAN Port 37 Way D Type Socket 54 Cables 55 DTE Cable 55 DT Line Cord for Structured Cabling 56 PRI BRI ISDN Cable 57 LAN Interconnect Cable 58 LAN Cable 59 LAN Crossover Cable 60 Expansion Interconnect Cable 61 V 24 V 28 WAN Cable 62 X 21...

Page 5: ... into a suitable rack system see page 42 The IP401 Compact Office can be wall mounted see page 43 System Programming System programming is necessary for installation and maintenance of the IP Office This manual only covers very basic programming see page 45 For full details refer to the Administration Help files contained on the Installation CD supplied with every unit Terminal Telephone Usage Thi...

Page 6: ... equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in...

Page 7: ... Yes IP406 Office No No Yes Yes No Yes IP412 Office No No Yes Yes No Yes See page 33 for country specific variant SAP codes Further Information and Product Updates Further information including Product and Reference Manual updates can be obtained from Avaya s Dealers and Distributors or from Avaya s web site http www avaya com This guide is also available from Avaya s support web site http support...

Page 8: ...ure 000 emergency number is not barred by performing the following Short Code 000 Telephone No 000 Function Dial Emergency WARNING This equipment will be inoperable during mains power failure IP Office Operation in Canada Industry Canada Notification DoC This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The ...

Page 9: ...t be through a USOC RJ45S Notification to the Telephone Companies Before connecting this equipment you or your equipment supplier must notify your local telephone company s business office of the telephone number or numbers you will be using with this equipment The facility interface codes FIC for 1 544 MBps digital connection i e IP400 Office PRI T1 are 04DU9 BN 04DU9 DN 04DU9 IKN 04DU9 ISN The f...

Page 10: ...upport Avaya 2000 series telephones DT ports are set to A Law PCM encoding at default but can be programmed to µ Law PCM encoding An IP401 Compact Office 2 can be expanded to an IP401 Compact Office 4 In addition the IP401 Compact Office can be fitted with any of the following optional Integral Modules WAN Port This port supports a single synchronous data connection which can be X 21 V 35 or V 24 ...

Page 11: ...location Converters can be used to provide BT New Plan sockets 431A 631A if required see page 65 When telephones are equipped with line cords that terminate in RJ11 plugs then pin to pin RJ11 RJ45 adapters should be used LAN Ports The auto negotiating 10 100 BaseT LAN hub ports are used for PC and server connectivity They can also be used to connect to IP telephones Avaya 4600 IP series LAN ports ...

Page 12: ...untry specific variants WAN Port This port supports a single synchronous data connection which can be X 21 V 35 or V 24 The selection of the required interface is automatically determined from the pin out of the cable plugged into the WAN port This cable must be connected before power is applied for auto detection to work Connection to a Digital Leased Circuit is made by connecting the WAN port on...

Page 13: ... remaining ports being used for a fax machine The eight port 10 100M Hub allows the local PCs and Printers to be networked Connectivity for all voice and data traffic between the Warehouse and the regional office is carried over the optional IP401 WAN interface using Voice over IP and standards based compression through the optional IP400 VCM 5 media card Two ISDN ports allow up to four simultaneo...

Page 14: ...of the following Expansion Modules can be supported by the IP403 Office base unit IP400 Digital Terminal 16 30 or Digital Station 16 30 Two variants of both 16 or 30 extensions for digital telephones see page 27 Hence if all 3 extension modules are IP400 Digital Terminal Station 30s then the maximum of 100 extensions will consist of 90 digital extensions plus the base unit s 2 analog extensions an...

Page 15: ...elephone location Converters can be used to provide BT New Plan sockets 431A 631A if required see page 65 When devices are equipped with line cords that terminate in RJ11 plugs then pin to pin RJ11 RJ45 adapters should be used LAN Ports The eight auto negotiating 10 100 BaseT LAN hub ports are used for PC and server connectivity They can also be used to connect to the optional IP400 WAN3 Expansion...

Page 16: ...page 33 for country specific variants and page 37 for grounding WAN Port This port supports a single synchronous data connection which can be X 21 V 35 or V 24 The selection of the required interface is automatically determined from the pin out of the cable plugged into the WAN port This cable must be connected before power is applied for auto detection to work Connection to a Digital Leased Circu...

Page 17: ...siness of this size would have a data network built using LAN switches such as the Avaya Cajun range The IP403 Compact Office would be connected to the data network through its integral 8 port Hub providing all users access to the Internet and IP Office productivity applications Kit List IP403 Office DT PRI 30 E1 3 x IP400 Digital Terminal Module 30 80 x 2030 Display Terminals EXPANSION DTE DC I P...

Page 18: ...h 16 or 30 extensions for digital telephones see page 27 Hence six IP400 Digital Terminal Station 30s will allow a maximum of 180 digital extensions IP400 Phone 8 16 30 Three variants 8 16 or 30 extensions for analog telephones see page 28 Hence six IP400 Phone 30s will allow a maximum of 180 analog extensions IP400 So8 An S bus module that provides 8 Basic rate ISDN interfaces see page 29 IP400 W...

Page 19: ...d Voice over IP VoIP calls Where IP telephony is required the hub must be connected to a suitable switch i e an Avaya Cajun P130 This eight port auto negotiating 10 100 BaseT LAN hub supports a single MAC address only printed on the base of the module Where more than eight LAN connections are required the eighth LAN port can be used for cascading to other hubs The Cascade pushbutton to the right o...

Page 20: ... is switchable in the installation software to provide 24B trunks See page 39 for installation page 33 for country specific variants and page 37 for grounding WAN Port This port supports a single synchronous data connection which can be X 21 V 35 or V 24 The selection of the required interface is automatically determined from the pin out of the cable plugged into the WAN port This cable must be co...

Page 21: ...DIO EXPANSION 1 2 3 4 5 6 DTE WAN EXT O P DC I P C 24V DC 2A Slot A BRI 1 2 3 4 BRI 1 2 3 4 Scenario 2 A business requiring 180 analog Telephones and 60 lines The configuration illustrates a fully configured IP406 Office providing 180 extensions and 60 trunks Factory shipped with a single PRI the system is fitted with an extra trunk card in its spare slot to provide the additional 30 lines Kit Lis...

Page 22: ...tensions for digital telephones see page 27 Hence nine IP400 Digital Terminal Station modules can be fitted to allow a maximum of 256 digital extensions e g eight equipped with 30 extensions and the ninth with sixteen extensions IP400 Phone 8 16 30 Three variants for 8 16 or 30 extensions for analog telephones see page 28 Hence nine IP400 Phone modules can be fitted to allow a maximum of 256 analo...

Page 23: ... calls can be forwarded to PC based applications via these ports These segmented Ethernet ports support separate IP and MAC addresses and hence a Firewall break may be implemented They also provide access to the router functionality configuration of the IP412 Office platform for both data and Voice over IP VoIP calls Where IP telephony is required a suitable switch i e an Avaya Cajun P130 must be ...

Page 24: ... T1trunks support both ISDN and Analog emulation The default setting is 23B 1D 46B 2D and is switchable in the installation software to become a 24B 48B trunk See page 39 for installation page 33 for country specific variants and page 37 for grounding WAN Port This port supports a single synchronous data connection which can be X 21 V 35 or V 24 The selection of the required interface is automatic...

Page 25: ...itted with an extra trunk card in its spare slot to provide the additional 48 lines Kit List IP412 Office PRI 48 T1 6 X IP400 Office Digital Station 30 Module 2 x IP400 Office Analog Trunk 16 180 x Avaya 6412 Digital Terminals EXPANSION 2 4 6 8 10 12 1 3 5 7 9 11 EXPANSION DC I P C 24V DC 2A PF2 PF1 EXPANSION DC I P C 24V DC 2A PF2 PF1 Slot B AUDIO DTE WAN EXT O P DC I P C 24V DC 2A Slot A PRI PRI...

Page 26: ...ired one of the 20 channel cards could be substituted for a smaller variant The IP Office softphone is iPhoneManager Pro which requires two types of Licence Keys which allow PhoneManager Lite supplied as standard to run as IP Extensions Kit List IP412 Office PRI 60 E1fitted with two optional IP400 Voice Compression Module 20s 90 x 4612 IP Hardphones IP400 PhoneManager Pro RFA IP400 iPhoneManager P...

Page 27: ...µ Law but can be switched in software to A Law refer to the Administration Manager Manual for details Using DT Line Cords see page 56 and standard structured wiring these RJ45 ports can be extended to the required telephone location In addition converters can be used to provide BT New Plan sockets 431A 631A if required see page 65 When devices are equipped with line cords that terminate in RJ11 pl...

Page 28: ... RJ45 ports can be extended to the required telephone location Converters can be used to provide BT New Plan sockets 431A 631A if required see page 65 When devices are equipped with line cords that terminate in RJ11 plugs then RJ11 RJ45 adapters should be used All analog telephones must conform to the port specification see page 67 Rear View all versions EXPANSION DTE DC I P C 24V DC 2A Expansion ...

Page 29: ... must not be connected to the external ISDN Connections Rear View EXPANSION DTE DC I P C 24V DC 2A Expansion Port DTE Port DC Power I P Socket Port connections Expansion Port Used to connect a So8 Module to the Expansion Ports of an IP Office platform DC Power I P Socket Socket for the external 24V DC unregulated power supply supplied with kit DTE Port A 25 way D type socket Used for connection to...

Page 30: ...cable plugged into the WAN port This cable must be connected before power is applied for auto detection to work Connection to a Digital Leased Circuit is made by connecting the WAN port on the rear of the unit to the existing Network Terminating Unit NTU via the appropriate X 21 V 35 or V 24 cable These cables are detailed in the table below see pages 62 63 and 64 for details Cable Type SAP Code V...

Page 31: ...an Expansion Ports of an IP400 Office platform DC Power I P Socket Socket for the external 24V DC unregulated power supply supplied with kit Protective Grounding Point Within the USA a protective grounding must be permanently fitted Connection of this protective grounding requires the use of suitable tools and must be connected at both ends before connection is made to the telecommunications netwo...

Page 32: ...ce DT4 A ROW 700184633 IP403 Office Variant A Law µ Law Country SAP Code IP403 Office DT No Trunks A ROW CALA 700210578 IP403 Office DT BRI 8 A ROW 700184641 IP403 Office DT PRI 30 E1 A ROW 700184658 IP403 Office DS No Trunks A ROW CALA 700234453 IP403 Office DS No Trunks µ NA 700210610 IP403 Office DS PRI 24 T1 µ NA 700184666 IP403 Office DS Analog 4 µ NA 700184674 IP406 Office Variant A Law µ La...

Page 33: ...T1 NA 700185200 IP400 DUAL PRI 48 T1 NA 700185218 Notes 1 For countries outside North America CALA use the ROW variant unless stated otherwise 2 PRI T1trunks support both ISDN and Analog emulation The default setting is 23B 1D and is switchable in the installation software to become a 24B trunk Power Supplies Common Lump in Line Power Supply units are supplied with each IP Office Expansion Module ...

Page 34: ... 30 ROW 700185069 IP400 Digital Stations Variant Country SAP Code IP400 Digital Station 16 ALL 700184807 IP400 Digital Station 30 ALL 700184880 IP400 Analog 16 Trunks Variant Country SAP Code IP400 Analog Trunk 16 NA CALA 700211360 IP400 Analog Trunk 16 EU EU 700241680 IP400 Analog Trunk 16 NZ NZ 700241698 IP400 So8 Variant Country SAP Code IP400 So8 ALL 700185077 IP400 WAN3 Variant Country SAP Co...

Page 35: ... or be using DHCP to obtain an IP address IP Cat 5E patch cable red supplied with system see page 57 IP Office Administration CD supplied with system IP Office Manager Application Manual supplied on CD with system IP Office Feature Key where software that requires a Licence Key is to be installed Space requirements Check that the planned location meets the following requirements Height A IP401 Com...

Page 36: ...ear a swimming pool 2 Avoid using a telephone other than a cordless type during an electrical storm There may be a remote risk of electric shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord and batteries indicated in this manual Do not dispose of batteries in a fire They may explode Check with local codes for possible special ...

Page 37: ...r end of the wire to the approved protective ground Functional Ground Within the USA only for areas with high lightning and or ESD we recommend that a functional ground is fitted to the following trunk modules on IP403 406 and 412 systems Trunk Module IP400 QUAD ANALOG IP400 SINGLE PRI T1 IP400 DUAL PRI T1 SAP Code 700185192 700185200 700185218 Note This functional ground is not a protective groun...

Page 38: ...eled Perform the following 1 Mount the IP Office modules in their final location free standing units are ideally stacked one upon another 2 Run the individual Lump in Line PSU cables back to the switchable mains supply but do not switch on or connect the PSUs to the IP Office modules 3 With the exception of a WAN3 module connect the IP Office base module to the Expansion Modules using Expansion In...

Page 39: ... securing screws and remove blanking plate 5 Insert the trunk module and secure with the two screws 6 Mount the trunk module in position as shown below and secure with the two snap in spacers except for PRI E1 R2 7 For CALA only on the PRI E1 R2 coax module use the shorting blocks to connect Rx1 GND to Tx1 GND and or Rx2 GND to Tx2 GND as required 8 Where required fit the functional ground see pag...

Page 40: ...he unit over and remove the four fixing screws from the base 3 Slide the cover from the unit 4 Mount the VCM in position as shown below and secure with the two snap in spacers 5 Replace cover and secure with the seven fixing screws Caution While installing ensure that you wear a ground wrist strap that is connected to a suitable grounding point Page 40 Installing a New System IP Office Installatio...

Page 41: ... and remove the four fixing screws from the base 3 Slide the cover from the unit 4 Mount the module in position as shown below and secure with the two snap in spacers 5 Replace the cover and secure with the seven fixing screws Caution While installing ensure that you wear a ground wrist strap that is connected to a suitable grounding point IP Office Installation Manual Installing a New System Page...

Page 42: ... operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring...

Page 43: ...t Procedure 1 Drill two holes 16cm apart horizontally or vertically see Caution 3 above Using suitable wall fixings wall plugs insert two No 8 Panhead screws 25mm long min not supplied into wall leaving approximately 1cm proud of wall 2 Fit the Z bracket item o below onto the base of the unit using the M3 Plastite self tapping screw supplied 3 Slide the IP401 Compact Office unit onto the two screw...

Page 44: ... s Only discard if a WAN module is being fitted see below On the rear panel press out the molding for the additional BRI RJ45 socket item t Plug the expansion board item u onto it s sockets and stand off hex pillars Ensure that the additional BRI RJ45 socket slots into the hole in the rear panel item t Secure the expansion board item u with the three retaining screws Mount the new front and existi...

Page 45: ...ce Cat 5E patch cable red supplied with system see page 57 IP Office Administration CD supplied with system IP Office Manager Application Manual supplied on CD with system IP Office Feature Key where software that requires a Licence Key is to be installed Note Once installed the software level of all software fitted to the IP Office system can be identified With Manager running use File Advanced U...

Page 46: ...To display the facilities available for this named operator s Configuration Tree from File select Open and when requested enter the password for the IP Office unit The default for the IP Office unit is password You must change the operator Names their Passwords and the Password for the IP Office unit as soon as possible A combination of at least 8 alpha and numeric characters is recommended for pa...

Page 47: ...ne 3 Insert the line cord into the wall socket 4 Insert the line cord into the telephone s base and route the cord thorough the cable channels to come out at the side rear of the telephone 5 Lift the handset check that you hear dial tone and make a test call to another extension 6 On a display telephone ensure that the display shows the number called and that the display is in the correct language...

Page 48: ...e is allowed 2 Drill the necessary holes and insert the wall plugs 3 Insert the screws leaving the heads approximately 3mm proud of the surface check by clipping a bracket over the screw head 4 Attach the brackets to the telephone Then slide the bracket key slots over the screw heads 5 Reverse the position of the handset retainer tab located below the hook switch on the telephone This keeps the ha...

Page 49: ...r a 4600 telephone provide a general overview on how to wall mount both series of telephones For safety instructions and details refer to the specific instructions for each telephone type supplied on the CD with the IP Office system IP Office Installation Manual Telephone Installation Page 49 40DHB0002USCL Issue 7 09 25 2002 Wall Mounting 44 4600 6400 Series Telephones ...

Page 50: ...e equipped been fitted with the appropriate functional protective grounds see page 37 Is the distribution wiring structured cabling satisfactory to the required national standards Are all wires and cables clearly labeled Is the site clean and tidy with all rubbish removed Information Have the telephone user guides been issued to the user Has the customer been made aware of the telephone number for...

Page 51: ...Do not use 4 Ring 5 Tip Pin 1 Pin 8 6 8 Do not use Power Fail and POT Ports RJ45 Pin No Description 1 3 Do not use 2 Connected to pin 6 4 Ring 5 Tip 6 Connected to pin 2 Pin 1 Pin 8 7 8 Do not use Pins 2 and 6 are shorted together and via a ringer capacitor connected to in 5 DS DT Ports RJ45 Pin No Description 1 3 Do not use 4 Sig 1 5 Sig 2 Pin 1 Pin 8 6 8 Do not use ISDN Port BRI RJ45 Pin No Desc...

Page 52: ...nnections exchanged Pin No Description Signal Direction 1 Receive Data Rx A Í 2 Receive Data Rx B Í 3 Transmit Data Tx A Î Pin 1 Pin 8 6 Transmit Data Tx B Î DTE Port 25 Way or 9 Way D Type socket Pin25 Pin1 Pin9 Pin1 Pin No 25 Way Pin No 9 Way Description Signal Direction 2 3 Receive Data Rx Í 3 2 Transmit Data Tx Î 4 7 Request to Send RTS Í 5 8 Clear to Send CTS Î 6 6 Data Set Ready DSR Î 7 5 Si...

Page 53: ...eld Connected to chassis Ground External Control Port 3 5mm Stereo Jack Socket Pin No Description 1 Circuit 1 2 Circuit 2 3 0 Volts Ground Chassis 4 Not Connected 5 Not Connected Control Circuit Information Control Circuit 1 Pin 2 and Pin 3 ensure that Pin 2 is at a positive voltage with respect to Pin 3 Control Circuit 2 Pin 1 and Pin 3 ensure that Pin 1 is at a positive voltage with respect to P...

Page 54: ... Í 30 V24 DSR Í 12 V24 CTS Í 31 N C 13 N C 32 V35 Tx A Î 14 V35 Tx B Î 33 V35 SCTE A Î 15 V35 SCTE B Î 34 V35 Gnd 16 V35 Rx B Î 35 V35 Rx A Î 17 V35 TxClk B Í 36 V35 TxClk A Í 18 V35 RxClk B Í 37 V35 RxClk A Í 19 CHASSIS Notes 1 For the USA only FCC Part 68 registered data circuit terminal equipment should be connected to the WAN Ports 2 For X21 V24 28 and V35 variants pins 7 and 25 are connected ...

Page 55: ...y A B C D A 25 Way or 9 Way on IP412 D Type Plug with UNC 4 40 locking screws B 9 Way D Type Socket with UNC 4 40 locking screws C 12 core screened cable each core is 7 0 203mm 24 AWG tinned copper stranded wire nominal capacitance of 95pF m resistance of 92 Ω km screened with tinned copper braid maximum working voltage of 440V rms and a Maximum current per core of 1A rms D 2 meters Pin Connection...

Page 56: ... modules this cable can be used to connect the module s PSU Line socket and the structured cabling The PSU s Tel socket must only be connected to the Line socket of the associated 4424D telephone using the D4BU cable supplied with the PSU This cable can be used to replace the RJ11 to BT Newplan plug that is attached to the 20 series telephones to allow connection to structured cabling Page 56 Tech...

Page 57: ...ite Twisted pair 4 5 Rx B Tx B White Blue Twisted pair 5 3 Tx A White Green Twisted pair 3 6 Tx B Green White Twisted pair 6 1 Rx A White Orange Twisted pair 1 2 Rx B Orange White Twisted pair 2 7 White Brown Twisted pair 7 8 Brown White Twisted pair 8 With reference to the TE Pins 7 and 8 are through connected for ease of construction They are not actually used Installation Manual Technical Data ...

Page 58: ... White Green 3 6 Green White Twisted Pair 4 4 Blue White 5 5 White Blue Twisted Pair 6 7 White Brown 7 8 Brown White Twisted Pair 8 This cable is used When connecting IP Office hub ports 1 7 directly to a PC When connecting a WAN3 to an IP403 406 hub port which is located in the same cabinet as the IP Office Pins 4 5 7 and 8 are through connected for ease of construction They are not actually used...

Page 59: ...Pair 6 4 Blue White 4 5 White Blue Twisted Pair 5 7 White Brown 7 8 Brown White Twisted Pair 8 This cable is used When connecting IP Office hub ports 1 7 directly to a PC When connecting a WAN3 port to an IP403 406 hub port which is not located in the same cabinet as the IP Office Pins 4 5 7 and 8 are through connected for ease of construction They are not actually used Installation Manual Technic...

Page 60: ...n Connections End A Color Cable Notes End B 1 White Orange 3 2 Orange White Twisted Pair 6 3 White Green 1 6 Green White Twisted Pair 2 This cable is used when connecting Hub Ports 1 7 directly to another Hub and for connecting a WAN3 to an IP412 Page 60 Technical Data IP Office Installation Manual Cables 40DHB0002USCL Issue 7 09 25 2002 ...

Page 61: ... Name Color Cable Notes End B 1 Rx A White Orange 1 2 Rx B Orange White Twisted Pair 2 3 Sync A White Green 3 6 Sync B Green White Twisted Pair 6 4 Clock A Blue White 4 5 Clock B White Blue Twisted Pair 5 7 Tx A White Brown 7 8 Tx B Brown White Twisted Pair 8 The RJ45 Plug Shell at each end of the cable is connected to the STP Cable Drain Wire Installation Manual Technical Data Page 61 IP Office 4...

Page 62: ... core of 1A rms E 3 meters Pin Connections End A Name End B 6 Ground 7 8 DTR Data Terminal Ready 20 9 Receive Data 3 10 Transmit Clock 15 11 DCD Data Carrier Detect 8 12 CTS Clear To Send 5 26 Transmit Data 2 27 RTS Request To Send 4 28 Receive Clock 17 29 RI Ring Indicator 22 30 DSR Data Set Ready 6 Connect pin 25 to pin 6 at End A only Pin 19 at end A is connected to the Screened Cable Drain Wir...

Page 63: ... drain E 3 meters Pin Connections End A Name Cable Notes End B 1 Receive Rx B 11 20 Receive Rx A Twisted Pair 4 4 Transmit Tx A 2 23 Transmit Tx B Twisted Pair 9 24 Control Ctl A 3 5 Control Ctl B Twisted Pair 10 2 Indicate Ind A 5 21 Indicate Ind B Twisted Pair 12 3 SE Timing S A 6 22 SE Timing S B Twisted Pair 13 6 Ground 8 Connect pin 7 to pin 6 at End A only Pin 19 at end A is connected to the...

Page 64: ...Send D 27 RTS Request To Send C 29 RI Ring Indicator J 30 DSR Data Set Ready E 32 Transmit Data A P 14 Transmit Data B Twisted Pair S 35 Receive Data A R 16 Receive Data B Twisted Pair T 36 Transmit Clock A Y 17 Transmit Clock B Twisted Pair AA 37 Receive Clock A V 18 Receive Clock B Twisted Pair X 33 External Clock A U 15 External Clock B Twisted Pair W 34 Ground B Connect pins 7 and 25 to pin 6 ...

Page 65: ...ns may be reversed as polarity is not important This adapter may be used with DT telephones fitted with BT Newplan plugs Out of Building Installation In the USA only installation of telephone and or other standard tip ring devices in another building requires the following In Range Out Of Building IROB protectors to protect the control unit and device from electrical surges must be fitted as follo...

Page 66: ...of EN 609050 1992 A3 1995 clause 2 3 for SELV circuits and with the requirements of clause 6 for TNV circuits after connections between equipment Compliance with FCC Rules Transmit and Receive Gain Settings for PRI T1 and Analog Ports The Gain settings are password controlled for use by qualified installation personnel only and must not be made available to the end user The default gain settings o...

Page 67: ...nection USA Interfaces PRI T1 Service Ground Start GS Default E M 56k data for 5ESS 56 64 64 restricted for 4ESS PRI ISDN Switch support 4ESS 5ESS DMS 100 DMS 250 includes conformance to ANSI T1 607 Bellcore Special Report SR4287 1992 PRI ISDN Services AT T Megacom 800 AT T WATS 4ESS AT T SDS Accunet 56kB s 64kB s 4ESS AT T Multiquest 4ESS Analog ports RJ45 sockets Loop start Ground start regional...

Page 68: ...RFC 1994 Challenge Handshake Authentication Protocol CCP RFC 1962 Compression Control Protocol STAC RFC 1974 Stac LZS Compression Protocol MPPC RFC 2118 Microsoft Point to Point Compression Protocol BACP RFC 2125 Bandwidth Allocation Control Protocol IPCP RFC 1332 Internet protocol Control Protocol TCP IP RFC 793 Transmission Control Protocol Internet Protocol DHCP RFC 1533 Dynamic Host Control Pr...

Page 69: ...ins supply 36 NTU 12 16 20 24 30 Packaging 38 Parts required 35 PCM encoding 10 14 15 27 µ Law 11 27 A Law 10 27 PCS level 32 Power Consumption 67 Supply 36 Power fail 31 47 PRI E1 14 16 18 20 22 67 PRI T1 14 16 18 20 22 33 67 Product description 5 Rack 5 Sales feature 12 16 20 24 30 Software Level 5 45 Upgrade 45 Space requirements 35 Clearance 35 Height 35 Width 35 Temperature 36 Terminal instal...

Page 70: ...t Technologies has been transferred or licensed to Avaya All trademarks identified by or TM are registered marks or trademarks respectively of Avaya Inc All other trademarks are the property of their respective owners This document contains propriety information of Avaya and is not to be disclosed or used except in accordance with applicable agreements Any comments or suggestions regarding this do...

Reviews: