Adding or Removing Hardware

Install DS1/T1 CPE loopback jack

Installation, Upgrades and Additions for Avaya CMC1 Media Gateways

303

June 2004

Administering the loopback jack

1

At the management terminal, enter 

change ds1

 

location

, where 

location

 is the DS1 interface 

circuit pack corresponding to the loopback jack.

2

Be sure the 

near-end CSU

 type is set to integrated.

3

On page 2 of the form, change the

 supply CPE loopback jack power 

field to y

Setting this field to y informs the technician that a loopback jack is present on the facility and 
allows the technician to determine that the facility is available for remote testing.

4

Enter 

save translation

 to save the new information.

Loopback testing with a smart jack

The loopback jack and smart jack isolate faults by dividing the DS1 span into 3 sections (see 

Figure 110

 

through 

Figure 112

):

From the 120A2 (or later) ICSU to the loopback jack

From the loopback jack to the smart jack (network interface point)

From the smart jack to the CO

The first two sections are your responsibility. The last is the responsibility of the DS1 service provider.

Testing the DS1 span from the ICSU to the 
loopback jack

The DS1 span test has 2 parts. 

Checking for circuit connectivity

The first part of the test powers-up the loopback jack and sends a signal from the DS1 circuit 
pack, through the wiring, to the loopback jack. The test allows about 10 seconds for the signal to 
loop around the loopback jack and return to the DS1 circuit pack. Then it sends the results to the 
management terminal and proceeds to the second part of the test.

The second part of the test sends the standard, 3-in-24 DS1 stress-testing pattern from the DS1 
board, through the loopback jack, and back to a bit error detector and counter on the DS1 board. A 
bit-error rate counter displays the results on the management terminal until you terminates the 
test.

Always perform both parts of the test. Proceed as follows.

Checking the integrity of local equipment

Before you go any further, make sure that the problem is actually on the DS1 span by testing the 
equipment that connects to the span at the near end. Test the DS1 circuit pack, and perform any needed 
maintenance or repairs.

Summary of Contents for CMC1

Page 1: ...Installation Upgrades and Additions for Avaya CMC1 Media Gateways 555 233 118 Issue 8 June 2004 ...

Page 2: ...sions may be either to through synchronous time multiplexed and or circuit based or asynchronous character message or packet based equipment or interfaces for reasons of Utilization of capabilities special to the accessed equipment Theft such as of intellectual property financial assets or toll facility access Eavesdropping privacy invasions to humans Mischief troubling but apparently innocuous ta...

Page 3: ...l aggregators to block access dialing codes is a violation of the Telephone Operator Consumers Act of 1990 REN Number For MCC1 SCC1 CMC1 G600 and G650 Media Gateways This equipment complies with Part 68 of the FCC rules On either the rear or inside the front cover of this equipment is a label that contains among other information the FCC registration number and ringer equivalence number REN for th...

Page 4: ...ons may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Declarations of Conformity United States FCC Part 68 Sup...

Page 5: ...ection 19 Remove Install circuit packs 19 1 Installing and Cabling the Cabinets 21 Read This First 21 License File 21 Pre installation checklist 21 Check Customer s Order 24 Correcting Shipping Errors 24 Unpack and Inspect 24 Comcodes for CMC1 26 Install the System Cabinets 29 Set the Carrier Address ID All Cabinets 29 Floor Mount the Cabinet 30 Wall Mount the Cabinets 31 Install Cabinet A Wall Mo...

Page 6: ...the Main Distribution Frame 59 Set Up System Access 59 Starting Terminal Emulation 59 Connecting a PC 60 Set Ringing Option 66 Activate and Administer the System 66 Power Up System 66 Deliver or Install the License File 67 Administer No License Emergency Numbers 67 System Administration 68 Install and Wire Telephones and Trunks 75 DCP analog and ISDN BRI 75 Install Attendant Console Optional 80 In...

Page 7: ...stall Emergency Transfer Unit and Associated Telephones 121 Install the Emergency Transfer Panel 121 Connect Modem to Telephone Network 128 External Modem Option Settings 129 2 Completing Installation and Cable Pinouts 133 System Administration 133 Alarms and Reporting 133 Resolve Alarms 133 Enable Alarm Origination to INADS 133 Register the Switch for Maintenance 134 Place a Test Call 137 Set Neo...

Page 8: ...61 Check SPE 165 Verify Software Version 165 Verify System Status 165 Disable Scheduled Maintenance and Alarm Origination to INADS 165 Check Link Status 166 Save Translations 166 Save Announcements if necessary 166 Shut Down DEFINITY AUDIX System if necessary 167 Replace Circuit Packs 167 Install the License File 168 Administer No License Emergency Numbers 169 Display Memory Configuration 169 Set ...

Page 9: ...77 Service interruption 177 Call Management System CMS 178 Software compatibility 178 Usable circuit packs 178 Wireless systems 178 Antistatic protection 178 Task table 179 Pre upgrade checklist 180 Go to the RFA website 181 Pre upgrade administration changes 183 Check SPE 187 Verify version 187 Verify system status 187 Disable scheduled maintenance and alarm origination 188 Check link status 188 ...

Page 10: ...tributed download procedure 199 Troubleshooting firmware downloads 209 Install TN464GP TN2464BP with Echo Cancellation 211 Add CO FX WATS and PCOL 214 Requirements 214 Installation 214 Add DID Trunks 214 Requirements 214 Installation 214 Add Tie Trunks 215 Requirements 215 Installation 215 Add DS1 Tie and OPS 216 Service Interruption 216 Add Speech Synthesis 217 Add Code Calling Access 217 Add Poo...

Page 11: ...es 227 Enter Added Translations 227 Resolve Alarms 227 Save Translations 228 Add Packet Bus Support 228 Disable Alarm Origination 228 Save Translations 228 Install Circuit Packs 228 Administer the Bus Bridge 228 Test the Packet Bus and C LAN Circuit Pack 229 Resolve Alarms 229 Enable Alarm Origination to INADS 229 Verify Customer Options 229 Add CallVisor ASAI 229 Enter Added Translations 229 Save...

Page 12: ...troller 235 Add IP Solutions 235 Add IP Media Processor 236 Add IP Interface Assembly 246 Installing an Integrated Channel Service Unit ICSU Module 273 Checking for required components 273 Installing the 120A3A CSU 274 Installing a J58890CG Power Distribution Unit 277 Mounting without a backing plate 277 Mounting with a backing plate 277 Install terminal server 278 Installing and administering the...

Page 13: ...299 Troubleshooting 300 Connect printers 300 Connecting printers using TCP IP 300 Install DS1 T1 CPE loopback jack 301 Installing a loopback jack 302 Administering the loopback jack 303 Loopback testing with a smart jack 303 Testing a loopback jack without a smart jack 311 Configurations using fiber multiplexers 313 Install ISDN converters and adapters 314 Converters for single carrier cabinets 31...

Page 14: ...System 330 ASAI and DEFINITY LAN Gateway 331 Avaya Interactive Response 331 Avaya EC500 Extension to Cellular 331 Call Accounting Systems 331 A Troubleshooting an Upgrade 333 Troubleshooting Guidelines 333 Troubleshooting Upgrades 333 No Translation After Upgrade 334 Translation Corruption Detected 334 Re install the ISDN PRI Links Only for Failed Upgrades 335 B Access Security Gateway 337 Using t...

Page 15: ...d face as follows command We show complete commands in this book but you can usually type an abbreviated version of the command For example list configuration station can be typed as list config sta Screen displays and names of fields are printed in constant width as follows screen display A screen is any form displayed on your computer or terminal monitor Variables are printed in italics as follo...

Page 16: ...NTER to save your changes the screen you were working on clears and the cursor returns to the command prompt The message line shows command successfully completed to indicate that the system accepted your changes Admonishments Admonishments in this book have the following meanings CAUTION Denotes possible harm to software possible loss of data or possible service interruptions WARNING Denotes poss...

Page 17: ...nline Services 4 Select Documentation 5 Select Recent Documents 6 Scroll down to find the latest release of DEFINITY Avaya Communication Manager documents 7 Search for the document number to view the latest version of the book Non Web This book and related books can be ordered directly from Globalware Solutions 200 Ward Hill Avenue Haverhill MA 01835 USA 1 800 457 1235 phone 1 800 457 1764 fax Non...

Page 18: ... Let us know what you like or don t like about this book Although we can t respond personally to all your feedback we promise we will read each response we receive Write to us at Avaya Inc Product Documentation Group 1300 W 120th Ave Westminster CO 80234 USA Fax to 303 538 1741 Send email to document avaya com Table 1 Avaya support Support Number DEFINITY Helpline for help with feature administrat...

Page 19: ...aya Communication Manager Existing passwords expire 24 hours after installation For Access Security Gateway ASG see Appendix B Access Security Gateway Antistatic Protection CAUTION When handling circuit packs or any components of a DEFINITY System always wear an antistatic wrist ground strap Connect the strap to an approved ground such as an unpainted metal surface on the DEFINITY System Remove In...

Page 20: ...About This Book Remove Install circuit packs 20 Installation Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 ...

Page 21: ...e file the switch does not provide normal call processing Pre installation checklist In order to be properly prepared for the installation have the items listed in Table 2 ready Table 2 Pre installation checklist Item No Item 1 Software Release Letter 2 Avaya Communication Manager on removable media 3 Extra formatted removable media 4 Authorized wrist grounding strap 5 Documentation book or PDF fi...

Page 22: ...tner avaya com APAC http www avaya apac com bp Contractors go to http www avaya com services rfa If you are unable to access RFA using your recommended portal try http rfa avaya com 2 Using your SSO log in to the RFA website 3 Follow the links to the RFA Information page 4 Complete the information necessary to create a License File NOTE If you have problems with a hardware serial number that is no...

Page 23: ...C to create a Switch Configuration File 2 When prompted type in the Transaction ID number 3 Use the FET instructions to create a new switch connection profile 4 Create the Switch Configuration File 5 Upload the Switch Configuration File to the RFA website 6 Deliver the License File to your laptop PC for installation later in this procedure If you have problems with RFA If you get an error message ...

Page 24: ... the nearest MSL Contact the appropriate location for specific instructions For Streamlined Implementation in the United States call 1 800 772 5409 Unpack and Inspect CAUTION A fully loaded system weighs 58 lbs 26 3 kg Use lifting precautions If the doors power unit and circuit packs are removed the unit weighs only 29 lbs 13 1 kg 1 Verify the equipment received See Figure 1 Equipment Packed with ...

Page 25: ...Left panel also acts as a wall mount template and as a floor mount pedestal 2 Compact modular cabinet 3 Right panel 4 U S Robotics external modem not shipped with all systems 5 12 x 1 inch shoulder screws 6 Processor interface cable not shipped with all cabinets 7 AC power cord NEMA 5 15P or IEC 320 8 Vertical TDM LAN bus cable not shipped with all systems 9 Horizontal TDM LAN bus cable not shippe...

Page 26: ...Bus Terminator AHF110 407772870 Vertical TDM LAN Bus Cable WP 91716 List 8 407772888 Horizontal TDM LAN Bus Cable WP 91716 List 9 706827717 Single Point Ground Block H600 487 14 inch 35 5 cm 6 AWG 40 16 mm2 Green Ground Wire 847987187 CMC 110 Cross Connect Assembly Main Distribution Frame 407676691 120 VAC Power Distribution Unit 145D 6 AC 107949364 650A Power Supply 700225782 Fan Assembly 4077450...

Page 27: ... ft 15 2 m shielded DS1 cable with 50 pin male on each end 104307434 C6E cable 100 ft 30 5 m shielded DS1 cable with 50 pin male to 50 pin female 104307475 C6F cable 50 ft 15 2 m shielded DS1 cable with 50 pin male to 3 in 7 6 cm stub 102381779 3B1A Carbon Block 104410147 3B1E W Wide Gap Gas Tube 105514756 3C1S Solid State 102904893 4B1C Carbon Block with Heat Coil 104401856 4B1E W Wide Gap Gas Tu...

Page 28: ...ransceiver 300A 106455348 Multi Mode Fiber Optic Transceiver 9823A 106455363 Multi Mode Fiber Optic Transceiver 9823B 407439975 Multi mode Fiber Interconnect Cable 20 ft 6 1 m 407598325 Single mode Fiber Interconnect Cable 20 ft 6 1 m 105357727 Single mode Fiber Optic Patch Cord 2 ft 0 6 m 106060718 Single mode 5 dB Attenuator 106060734 Single mode 10 dB Attenuator Table 4 Comcodes for CMC1 Comcod...

Page 29: ...binets Set the Carrier Address ID All Cabinets Figure 2 Setting Carrier Address ID Right Side 1 Proceed to either Floor Mount the Cabinet on page 30 or to Wall Mount the Cabinets on page 31 Figure notes A Carrier A switch settings B Carrier B switch settings C Carrier C switch settings OFF OPEN 1 2 3 4 5 6 swdmdip KLC 082002 OPEN 1 2 3 4 5 6 B OPEN 1 2 3 4 5 6 A C ...

Page 30: ...in 72 4 cm high 24 5 in 62 2 cm wide and 12 in 30 5 cm deep Maintain a service clearance of 12 in 30 5 cm on the left right and front of the cabinet Figure 3 Typical Floor Mount Installation 1 Proceed to Cable the System on page 44 Figure notes 1 Left panel floor mount pedestal 2 12 x 1 in 2 5 cm shoulder screws 3 12 in 30 5 cm minimum from nearest object required to service the circuit packs indm...

Page 31: ...inet Installation 1 Install a 3 4 in 2 cm thick sheet of 2 x 4 ft 0 6 x 1 2 m plywood horizontally onto the wall See Figure 4 Left Panel Used as Mounting Template on page 32 The top of the plywood must be at least 54 in 137 cm from the floor 2 or 3 Vertically Mounted Cabinets 1 Install a 3 4 in 2 cm thick sheet of 4 x 8 ft 1 2 x 2 4 m plywood vertically onto the wall See Figure 6 Typical Vertical ...

Page 32: ...all ensuring that the top surface is level 2 Mark two 1 8 in 0 3 cm pilot holes in the mounting hole locations 3 Remove the template from the wall 4 Drill the two pilot holes 5 Thread two 12 x 1 in shoulder screws partially into the holes 6 Set the cabinet onto the wall and align the slots with the shoulder screws See Figure 5 Typical Wall Mount Installation on page 33 Slide the cabinet to the lef...

Page 33: ...ys 33 June 2004 Figure 5 Typical Wall Mount Installation 7 Drill two lower mounting holes using the cabinet as a template 8 Thread the 2 lower screws and tighten CAUTION Be sure the right bottom safety screw is in place and tight indmins1 KLC 110397 FLOOR A 2 1 Figure notes 1 12 x 1 in shoulder screws 2 12 x 1 inch safety screw ...

Page 34: ...s June 2004 Install 2 or 3 Vertically Mounted Cabinets Figure 6 Typical Vertical Multicabinet Installation 1 Securely tighten the shoulder screws and safety screws Figure notes 1 12 x 1 inch shoulder screws 2 12 x 1 inch safety screw Floor indmins7 KLC 082002 5 12 7 cm 12 30 5 cm 29 1 2 75 cm 78 1 2 199 4 cm A C B 48 122 cm 1 1 2 1 ...

Page 35: ...Install 2 Cabinets Vertically and 1 Cabinet Horizontally Figure 7 Typical 3 Cabinet Installation 1 Securely tighten the shoulder screws and safety screws Figure notes 1 12 x 1 inch shoulder screws 2 12 x 1 inch safety screw 3 Second sheet of plywood Floor indmins9 KLC 082002 29 1 2 75 cm 54 137 cm 5 12 7 cm 12 30 5 cm 96 244 cm 1 1 2 3 A C B 1 ...

Page 36: ... AC Power and Ground CAUTION The system requires a dedicated AC power circuit that is not shared with other equipment and is not controlled by a wall switch The AC receptacle must not be located under the Main Distribution Frame and must be easily accessible CAUTION The latch only removes DC power from the cabinet Unseating the power supply removes AC power from the power supply but not from the c...

Page 37: ...en the neutral and ground side of the receptacle 4 Verify that the meter reads 0 VAC If not have a qualified electrician correct the problem 5 When finished set the AC mains circuit breakers to OFF Approved Grounds An approved ground is the closest acceptable medium for grounding the building entrance protector entrance cable shield or single point ground of electronic telephony equipment If more ...

Page 38: ... each floor of a high rise building that are suitable for connection to the ground terminal in the riser closet and to the cabinet single point ground terminal Approved floor grounds may include Building steel The grounding conductor for the secondary side of the power transformer feeding the floor Metallic water pipes Power feed metallic conduit supplying panel boards on the floor A grounding poi...

Page 39: ...nce connector on the rear of the cabinet See Figure 9 Figure 9 CMC Power Supply Connect Cabinet Grounds and Other Grounds The following additional grounding requirements must be met The approved ground wire must be green 6 AWG 40 16 mm2 copper stranded wire this is in addition to the ground wire in the AC power cord Bond all approved grounds at the single point ground to form a single grounding el...

Page 40: ...wer and Ground 40 Installation Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 Figure 10 Ground Block Installation to Right Panel Figure notes 1 12 x 1 inch shoulder screws 2 Single point ground block indmingb RPY 012398 1 2 2 A ...

Page 41: ...ounding Figure notes 1 6 AWG 40 16 mm2 cabinet ground wire 2 6 AWG 40 16 mm2 ground wire to next cabinet 3 Single point ground block 4 AC load center single point ground 5 10 AWG 25 6 mm2 wire to coupled bonding conductor CBC 6 6 AWG 40 16 mm2 ground wire from single point ground block to the AC load center single point ground 5 cadmgrd1 KLC 020698 4 2 1 1 1 3 6 ...

Page 42: ...to a telephone cable building entrance protector ground that is connected to an approved ground 2 Route the rest of the conductor next to the exposed telephone cables being protected until they reach the cross connect nearest to the telephone system 3 Position the non exposed telephone cables at least 12 inches 30 5 cm away from exposed telephone cables whenever possible 4 Terminate the other end ...

Page 43: ...ons for Avaya CMC1 Media Gateways 43 June 2004 Figure 12 Routing AC Power Cords to a Power Distribution Unit Figure notes 1 Cabinet AC power cord 2 Surge protected AC power distribution unit 120 VAC systems optional LINE FAULT GROUND OK ALWAYS ON POWER PROTECTIO N pcdm5cmc RPY 011998 1 1 2 ...

Page 44: ... you need to interconnect all the cabinets in the system Install Processor Interface Cable Cabinet A Only and TDM LAN Bus Terminator Figure 13 System Cable Connections 1 Connect the Processor Interface Cable to slot 1 of Cabinet A See Figure 13 2 Install the TDM LAN bus terminators Figure notes 1 TDM LAN bus terminator 2 Processor interface cable cabinet A only cadm1mds LJK 060297 ...

Page 45: ... Cable the Multi Cabinet System Wall Mount Vertically Mounted System 1 Route the TDM LAN bus cables through the cable trough See Figure 14 Figure 14 TDM LAN Bus Cables and Terminators Figure notes 1 TDM LAN bus terminator at each end of the TDM LAN bus 2 Vertical TDM LAN bus cable List 8 cadm3trm KLC 082102 A B C TOP 1 1 1 2 2 2 2 ...

Page 46: ... Mounted System Only 1 horizontal TDM LAN Bus cable is allowed per system See Figure 15 1 Route the TDM LAN bus cables through the cable trough Figure 15 System Cable Connections Figure notes 1 TDM LAN bus terminator at each end of the TDM LAN bus 2 Vertical TDM LAN bus cable List 8 3 Horizontal TDM LAN bus cable List 9 indmin10 KLC 082002 B A C 1 TOP 1 1 3 2 ...

Page 47: ...3 cm otherwise the right cover panel cannot fit over the right panel The optional MDF represents the trunk auxiliary field 1 Mount the optional MDF to the right panel using one of the following For bottom mount MDFs refer to Bottom mounted MDF with Modem on page 47 For top mount MDFs in cabinets other than cabinet A refer to Top Mounted MDF on page 49 For dual mount MDFs refer to Dual MDFs on page...

Page 48: ...1 Media Gateways June 2004 Figure 16 Typical Bottom Mount MDF and Modem Cable Routing Figure notes 1 Main distribution frame MDF 2 External modem 3 Processor interface cable connect P2 to modem connect J1 to cable 1 on MDF 4 12 x 1 inch shoulder screw cadmrpnl KLC 070698 1 1 2 5 6 7 8 4 3 9 10 3 1 2 4 10 10 9 9 8 8 7 7 6 6 5 5 4 4 3 3 2 2 1 1 ...

Page 49: ...onfiguration for cabinet A Figure 17 Typical Top Mount MDF Cable Routing 1 On the rear of the MDF cut the cable tie securing the top 5 cables to the MDF mounting frame 2 Mount the MDF to the right panel See Figure 17 3 Secure all 10 cables to the bottom left bracket on the MDF with a cable tie Figure notes 1 Main distribution frame MDF 2 Connect cable 1 to slot 1 3 12 x 1 inch shoulder screw cadmm...

Page 50: ... tie securing the top 5 cables to the MDF mounting frame 2 Mount the MDF to the bottom position on the right panel See Figure 18 Preliminary Dual Mount MDF Cable Routing on page 50 3 Secure all 10 cables to the bottom left bracket on the MDF with a cable tie 4 Mount the second MDF to the top position on the right panel See Figure 19 Figure notes 1 Main distribution frame MDF 2 Connect cable 1 to s...

Page 51: ...ngs NOTE You may use a locally obtained type approved external modem 33 6 kbps and V 34 protocol Contact your Avaya Inc representative for more information 1 Use installer provided hardware to mount the modem See Figure 16 Typical Bottom Mount MDF and Modem Cable Routing on page 48 If top mounting MDFs or dual mounting MDFs mount the external modem to the plywood in a location which allows the sta...

Page 52: ...tem always wear an authorized wrist ground strap Connect the strap to the ground connector provided on the system cabinet NOTE Unlike previous releases of DEFINITY the circuit pack slots in the CMC are not purple or white This is because all of the circuit pack slots in the CMC are universal slots That is any slot can contain any type of port circuit pack Circuit Pack Slot Loading In general load ...

Page 53: ...cuit pack slots scdmlft3 KLC 090700 5 10 1 2 3 4 6 1 2 T N 2 1 8 2 B MAJ MIN ON OFF AMBER CARD IN USE RED EMER XFER ON EM XFR AUTO T N 2 4 0 2 Table 5 Circuit Pack Installation Order Loading Function Apparatus Code Load From Notes Processor TN2402 Slot 1 in Cabinet A Tone Clock TN2182C Slot 2 in Cabinet A Call Classifier Tone Detector TN744E Slot 1 of Cabinet B If slot is not available load in fir...

Page 54: ...stworks and BCS only Lower Left Maximum of 8 ISDN PRI Total number of ISDN PRI plus number of ISDN BRI circuit packs must not exceed 8 ISDN BRI Trunk TN2185B Lower Left Maximum of 4 CO Trunk TN747B TN465C TN2199 TN2147C TN2138 TN438B Lower Left DID Trunk TN753B TN2139 TN2146 TN436B TN459B Lower Left Tie Trunk TN760E TN497 TN2140B Lower Left Auxiliary Trunk TN763D Lower Left Modem Pool TN758 Lower ...

Page 55: ...1 Figure 21 Example MDF Connections widfccf3 KLC 020802 4 1 10 19 4 13 22 2 11 20 5 14 23 3 12 21 6 15 24 9 18 7 16 25 8 17 Port Tie Trunk 4 Port Tie Trunk w E M Signaling Port Data Line 8 Port Digital 8 Port BRI 12 Port Hybrid 8 Port DID 8 Port Analog Port CO 8 8 1 10 19 4 13 22 2 11 20 5 14 23 3 12 21 6 15 24 9 18 7 16 25 8 17 Port Digital 24 24 32 16 Port Analog Port Analog 16 24 Port Digital C...

Page 56: ...f 350 mA and a minimum voltage rating of 600V or as required by local regulations The following devices protect the system from over voltages Analog trunks use the 507B sneak protector or equivalent Over voltage protection is normally provided by the local telephone company Analog voice terminals use one of the following types of combined over voltage and sneak current protection or equivalent Car...

Page 57: ...ocks equipped with SCP 110 protectors for sneak current protection NOTE Sneak current protectors with a rating of 350 mA at 600 V must be UL listed for United States installations and CSA certified for Canadian installations The panel contains two 25 pair connectors fuse removal tool and fifty 220029 Sneak Fuses and 2 spares Use the SCP 110 protectors with 110 type hardware and on the 507B Sneak F...

Page 58: ...Table 6 is a pinout of the cable wiring and associated fuse numbers Table 6 Sneak Fuse Connector Pinout Connector Pin Numbers Pair Fuse Number 26 1 1 27 2 2 28 3 3 29 4 4 30 5 5 31 6 6 32 7 7 33 8 8 34 9 9 35 10 10 36 11 11 37 12 12 38 13 13 39 14 14 40 15 15 41 16 16 42 17 17 43 18 18 44 19 19 45 20 20 46 21 21 47 22 22 48 23 23 49 34 24 50 25 25 ...

Page 59: ... Label Graphic Symbols and Nomenclature 1 Label the cables as required using the supplied labels Label code number 220A Comcode 103970000 contains all required labels Set Up System Access For SAT commands use a terminal emulation application such as Avaya Native Configuration Manager or HyperTerminal You can also use Avaya Site Administration part of Avaya Integrated Management Starting Terminal E...

Page 60: ... connect your PC laptop either directly 50 ft 15 m or less or remotely through a data module or a modem Direct connection You can connect directly from the PC if it is 50 ft 15 m or less from the Avaya CMC1 Media Gateway 1 Connect the equipment as shown in Figure 24 CAUTION For a DC powered system install an EIA 116A Isolator comcode 106005242 in series between the cable and the TERM DOT or Termin...

Page 61: ... Figure 25 A typical remote connection using an 8400B top or 7400B bottom data module NOTE With a 7400B data module use a 4 wire digital line circuit pack With the 8400B data module use a 2 wire digital line circuit pack Figure notes 1 Avaya CMC1 Media Gateway 2 Digital line circuit pack 3 B25A 25 pair cable 4 Main distribution frame MDF 5 103A or modular wall jack 6 400B2 adapter 7 D6AP power cor...

Page 62: ... unit performs a self test NOTE The power LED must be steady on If the power LED is blinking the data module is not communicating with the Avaya CMC1 Media Gateway Check the wiring at the MDF wall jacks and data module Adding a data module 1 Type add data module number or add data module next 2 In the Type field type pdm and press Enter 3 In the Port field type the location of the digital line cir...

Page 63: ...Remove the power cord from the unit b Remove the cover from the top rear of the unit c Set the dip switches d Replace the cover e Connect the power cord The unit performs a self test 2 If any switches were set in step 1 cycle the power to the data module so that the firmware can read the new switch settings 7400B The Power and TR LEDs should be steady on If the Power and Data LEDs are blinking the...

Page 64: ... No Telephone Connected 1 On Data Metering 5 Off Suppress Touch tone Dial Tone 6 Off Speakerphone Disable Enable 7 Off Busyout on Local Loop 8 Off Unused DIP Switches 2 3 and 4 Off Figure notes 1 Computer with Avaya Site Administration 2 50 ft 15 m M25A cable RS 232 9 25 pin adapter if needed 3 Analog modem 4 7 ft 2 m D2W modular cord 5 103A or modular wall jack 6 Main distribution frame MDF 7 Ana...

Page 65: ... an AC power outlet 5 Turn on the modem 6 Set the following port settings Table 8 U S Robotics Modem Dip Switch Settings Dip Switch Setting Description 1 UP DOWN Data Terminal Ready normal Data Terminal Ready override 2 UP DOWN Verbal result codes Numeric result codes 3 UP DOWN Suppress result codes Display result codes 4 UP DOWN Echo offline commands No echo offline commands 5 UP DOWN Auto answer...

Page 66: ... of the power unit Activate and Administer the System NOTE The Avaya CMC1 Media Gateway is a PPN cabinet only Cabinet A is the control carrier and Cabinets B and C are port carriers Power Up System Single Cabinet Installations 1 Insert the translation card into the slot in the TN2402 Processor circuit pack 2 Fully seat the 650A Power Unit in the cabinet 3 Set the circuit breaker at the AC load cen...

Page 67: ... connection 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File to your laptop PC 2 Open the License Installation Tool LIT application at your laptop PC 3 Use the LIT instructions to add a switch connection profile to the tool 4 Use the LIT instructions to install the License File on the Avaya CMC1 Media Gatewa...

Page 68: ...FINITY Server CSI 1 Type status system all cabinets and press Enter 2 Verify the screen displays a service state of in for all appropriate areas Check Customer Options Refer to Administrator s Guide for Avaya Communication Manager to view a sample screen Certain features are part of Avaya Communication Manager and do not require activation They default to y yes on the Optional Features form ARS AA...

Page 69: ...red alarm LEDs off 3 Set the country codes as needed in the following fields Refer to Table 9 Country Codes on page 69 for the country codes The United States country code 1 is shown in the example above Digital Loss Plan Analog Ringing Cadence Analog Line Transmission Table 9 Country Codes Country Code Country Code USA 1 Germany 13 Australia 2 Czechoslovakia 14 Japan 3 Russia 15 Italy 4 Argentina...

Page 70: ...pment is connected to the port circuit packs alarms associated with these ports can take up to 4 hours to log but clear automatically after all equipment is installed and operating correctly Change Craft Password The password for the craft login must be changed by the installing technician to prevent unauthorized administration changes CAUTION After the password is changed the new password must be...

Page 71: ... rules and press Enter Figure 30 Daylight Savings Rules screen change password craft Page 1 of 1 PASSWORD ADMINISTRATION Password of Login Making Change LOGIN BEING CHANGED Login Name craft LOGIN S PASSWORD INFORMATION Login s Password Reenter Login s Password DAYLIGHT SAVINGS RULES Rule Change Day Month___Date Time____Increment 0 No Daylight Savings 1 Start first Sunday___ on or after April___ 1 ...

Page 72: ...ule if it is in use on either the Locations or Date and Time screens 3 Press Enter Set Date and Time 1 Enter set time and press Enter Figure 31 Date and Time screen 2 In the Day of the Week field type the day of the week in English Sunday through Saturday See Table 10 for English day of the week names Table 10 English Day of the Week Names Day Number Day Name 1 Sunday 2 Monday 3 Tuesday 4 Wednesda...

Page 73: ...o daylight savings 9 Press Enter to effect the changes Circuit Pack Administration After the equipment is installed including circuit packs the circuit packs must be administered Refer to Administrator s Guide for Avaya Communication Manager for more information The following describes general administration information Use the Circuit Packs form to administer circuit packs to carrier slots The ci...

Page 74: ...ed Administer the Attendant Console If no attendant console is installed proceed to Save Translations 1 Enter display system parameters country options and press Enter Verify the system s companding mode for its local stations usually A Law for Europe and mu Law for North America and Japan 2 If necessary enter change terminal parameters 603 302B1 to change the default system level parameters and a...

Page 75: ...wns and is best viewed from CD ROM or on line After installing the hardware the data for the system and telephone features is administered These procedures are provided in Administrator s Guide for Avaya Communication Manager DCP analog and ISDN BRI The 302D Attendant Console describes a typical telephone connection This information is typical of the 603E 84xx 4 wire and 94xx telephones The attend...

Page 76: ...g 1 Choose a peripheral to connect such as a 2 wire digital station 2 Choose the port circuit pack to use and its carrier and slot number For example TN2183 Analog Line Cabinet 1 Carrier C Slot 1 3 Choose a port circuit on the port circuit pack for example port 3 4 Install cross connect jumpers to connect the pins from the 2 wire station to the appropriate pins on the port circuit pack 5 Administe...

Page 77: ...rnal tie trunk Names of the tie trunk leads must be determined from the manufacturer or supplier of the external trunk circuit The example in Figure 34 shows a DEFINITY System tie trunk connected to a DEFINITY System tie trunk 3 Administer on the Trunk Group Screen See Administrator s Guide for Avaya Communication Manager Digital Tie Trunk Example Figure 35 Digital Tie Trunk Wiring Figure notes 1 ...

Page 78: ...connector cable 50 foot 15 2 m shielded cable with a 50 pin male connector on each end Use to connect a DS1 tie trunks in collocated cabinets C6E connector cable 100 foot 30 5 m shielded cable with a 50 pin male connector on 1 end and a 50 pin female connector on the other end Use as an extension cable between the DS1 tie trunk circuit pack and other connector cables C6F connector cable 50 foot 15...

Page 79: ...1 tie trunks with the 1 544 Mbps digital facility Contact your Avaya Inc representative for maximum cabling distances Figure 36 Typical Connections to Channel Service Unit 3 Pair and 4 Pair Modularity Figure 37 shows 3 pair and 4 pair modularity from the port circuit pack to the voice or data terminal Most terminals connect to an information outlet modular jack installed at the work location Figur...

Page 80: ...de for Avaya Communication Manager Hard Wire Bridging CAUTION Bridging or paralleling these endpoints can cause electrical damage to the consoles or cause the circuit pack to remove power from the consoles Analog type hard wire bridging is not allowed for 4 wire only DCP endpoints This is because hard wire bridging provides no way of combining the digital output of 2 bridged DCP sets Also a bridge...

Page 81: ...S BLF jack 3 Attach labels according to the Attendant Console form 4 Administer the console using Administrator s Guide for Avaya Communication Manager Administer IP Stations and Trunks For complete information on administering IP stations and trunks see Administrator s Guide for Avaya Communication Manager Install and Wire Telephone Power Supplies This section provides information and wiring exam...

Page 82: ...2 Adapter Connecting to a Modular Plug Adjunct power can be provided from the equipment room or equipment closet with 1145B power unit The AUX connector J1 on the processor interface cable can provide power for 1 attendant console See Table 36 Processor Interface Cable Pinout on page 144 Adjunct power can be provided locally at the telephone or console by the 1151B or 1151B2 Power Supply Figure no...

Page 83: ... Only 1 console can derive auxiliary power from the system and through the auxiliary cable located in the trunk auxiliary field A console s maximum distance from its auxiliary power source is 800 feet 244 m for a 302A1 350 feet 107 m for a 301B1 and 302D Figure notes 1 Typical display telephone 2 Individual power supply Such as 1151B Not used if item 14 is used 3 400B2 adapter 4 Information outlet...

Page 84: ...C power interruptions batteries automatically provide power to the load NOTE Before you begin read this Important Warning for 1145B2 Power Supply on page 85 Perform these tasks in order 1 Install the Wall Mounting Plates on page 89 2 Mount the 1146B2 Power Distribution Unit on page 89 3 Install the Battery Mounting Wiring on page 89 4 Install the Expanded Power Distribution Unit on page 90 5 Power...

Page 85: ...ntact an electrician to replace the outlet Do not defeat the safety purpose of the grounding plug Do not allow anything to rest on or spill into the products To reduce risk of fire and electrical shock do not overload power outlets Never push objects of any kind through the power supply or distribution unit slots as they may touch dangerous voltage points or short out parts that could result in a ...

Page 86: ...allows the user to redirect reserve power to outputs 1 through 32 so all outputs are provided battery reserve power or to outputs 1 through 8 to provide high power above 6 25 watts NOTE The switch must be set to the 1 32 position The 1145B22 1146B2 is a 48 V power supply with 275 watts total output Each output circuit is current limited by a Polymer Positive Temperature Coefficient Resistance Devi...

Page 87: ... Mounting Plate 2 Battery 1149B Shown 3 1146B2 Power Distribution Unit 4 1145B2 Power Unit 5 Power Cable 6 Nonswitched Outlet 120 VAC 20 amp or 230 VAC 15 amp 7 Battery Backup Switch Setting 1145 Power Unit 1149 Battery On Battery Reserve Charging Battery Output Power On 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 48V 48V RTN RTN Unit No Connected To 1 8 ...

Page 88: ... Power Distribution Unit 3 T Cable H600 347 G7 4 First 1146B2 Power Distribution Unit 5 1145B2 Power Unit 1145 Power Unit 1149 Battery On Battery Reserve Charging Battery Output Power On 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 48V 48V RTN RTN Unit No Connected To 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 48...

Page 89: ...screw is located next to the AC outlet to the left of the unit Mount the 1146B2 Power Distribution Unit See the 1146B2 Power Distribution Unit in Expanded Power Distribution Unit on page 88 1 Insert and securely tighten the two supplied 8 32 x 1 2 inch shoulder screws they have an unthreaded section at the top into the top holes designated for 1146B2 Power Distribution Unit on the bottom plate Mou...

Page 90: ...ng plate and secure with the 8 32 x 1 2 inch shoulder screws The spacer bracket is not shown in the figure but is installed behind the top power distribution unit 2 Slide the keyhole slots in the power distribution unit over the shoulder screws 3 Insert the 8 32 x 1 inch screw through the distribution unit through the spacer bracket and into the plate The mounting hole is located just above the wi...

Page 91: ...er cord and connections are good replace the power unit 4 Disconnect the AC plug on the power supply this activates the DC supply 5 Check DC battery back up operation of the 1145B2 Power Supply by monitoring the LEDs PASS The red and green LEDs should be lit together Red means the power supply is on battery back up FAIL If either green or red LED is not lit after disconnecting AC power check the c...

Page 92: ...ck 2 If the LED goes off the terminal equipment is faulty and must be replaced If the LED is still lit find and repair the short circuit in the building wiring 3 Reconnect the terminal equipment to the wall jack and retest terminal equipment operation Figure notes 1 Power Supply Kit 2 2 5 5 0 or 8 0 Amp Hour Battery 3 1146B2 Distribution Unit 4 1145B2 Power Supply 5 Circuits 1 16 6 Circuits 17 32 ...

Page 93: ...ectric shock and injury to persons Read and understand all instructions Follow all warnings and instructions marked on this switch This product can be hazardous if immersed in water To avoid the possibility of electrical shock do not use it near water The 1152A1 PDU contains components sensitive to electrostatic discharge Do not touch the circuit boards unless instructed to do so This product shou...

Page 94: ... guide that comes with the unit for complete installation instructions Connect the 1152A1 PDU CAUTION The 1152A1 PDU has no ON OFF switch To connect or disconnect power to the 1152A1 PDU simply insert or remove the power cable from the AC power receptacle on the rear of the 1152A1 PDU 1 Plug a power cord into the power socket on the rear of the 1152A1 Power Distribution Unit 2 Plug the other end o...

Page 95: ...termed Power over LAN Enabled receive power once they are connected to the 1152A1 PDU To safeguard devices that are not enabled the 1152A1 PDU detects devices that are not enabled so does not send power Note that data continues to flow via the Ethernet cable regardless of the status of the end device End devices that are not enabled to receive power directly may receive power and data through an e...

Page 96: ...let 3 On the front panel of the 1152A1 PDU monitor the response of the corresponding port LED If it lights up GREEN the unit has identified your telephone as a Power over LAN P333T PWR Power over Ethernet Stackable Switch The P333T PWR power supply complies with the Underwriters Laboratories Inc UL standard UL 1950 second edition For safety instructions see P333T PWR switch Important Safety Instru...

Page 97: ...has been damaged If it exhibits a distinct change in performance If it does not operate normally when following the operating instructions Using the P333T PWR switch The P333T PWR Power over Ethernet Stackable Switch can be used to power 46xx series IP telephones in addition to providing a 10 100 megabits per second Ethernet connection The switch can form part of a stack with the G700 Media Gatewa...

Page 98: ...ish to use the optional DC input for the following Backup for the power over Ethernet ports To provide more than 200 watts for the power over Ethernet ports NOTE Please refer to the P333T PWR switch User s Guide for more information Connect the Cables Connect IP telephones PCs servers routers workstations and hubs 1 Connect the Ethernet connection cable not supplied to a 10 100 megabits per second...

Page 99: ...wer supply This product can be hazardous if immersed in water To avoid the possibility of electrical shock do not use it near water To reduce the risk of electric shock do not disassemble this product except to replace the battery This product should be operated only from the type of AC power source indicated on the label If you are not sure of the type of AC power being provided contact a qualifi...

Page 100: ...ts DC 0 4 amperes and can operate from either a 120 volts AC 60 hertz power source 105 to 129 volts AC or a 220 230 240 volts AC 50 hertz power source 198 to 264 volts AC Input voltage selection is automatic The output capacity is 19 2 watts The power supply can be placed on a flat surface such as a desk For wall mounting keyhole slots are provided on the bottom of the chassis CAUTION Do not locat...

Page 101: ...AUX connector J1 on Processor Interface Cable See Table 19 Alarm Output The system provides a relay contact that can operate a customer provided alarm such as a light or bell The circuitry and power source are customer provided The alarm device must not exceed a rating of more than 30 VAC RMS or 60 VDC at 0 75 Amps 1 Connect the external alarm output See Table 20 2 Give this information to your Av...

Page 102: ...signations Table 21 Emergency Transfer and Auxiliary Power Power Type Color AUX Connector Emergency Transfer Black Blue XFER48 Pin 36 Blue Black Ground Pin 11 Auxiliary Adjunct 48 VDC Brown Yellow ACC48A Pin 19 Yellow Brown Ground Pin 44 Table 22 Port Circuit Pack and Telephone Pin Designations Pin on Modular Plug 4 wire 302D 8400 Series 603E 9403 9434 2 wire 302D 8400 Series 603E 9403 9410 9434 8...

Page 103: ...later CO trunk circuit pack in any available port slot 2 Be sure the TN744E Call Classifier Detector circuit pack is Vintage 2 or later 3 Wire the CAMA trunk to the MDF the trunk from the CO Refer to the pinouts in Table 42 Circuit Pack and Auxiliary Equipment Leads Pinout Charts on page 152 Administration Setup 1 At the prompt type add trunk next and press Enter Figure 47 CAMA Trunk Group form pa...

Page 104: ...roll to page 3 of the form Figure 48 Administrable Timers form page 3 8 On the Administrable Timers screen page 3 you may need to adjust these fields according to your CO Scroll to page 5 Figure 49 Group Member Assignments form page 5 Page 3 of 11 TRUNK GROUP ADMINISTRABLE TIMERS Outgoing Disconnect msec 400 Cama Outgoing Dial Guard msec 75 Outgoing Glare Guard msec 1000 Cama Wink Start Time msec ...

Page 105: ...List1 Access Code ____ Abbreviated Dialing List2 Access Code ____ Abbreviated Dialing List3 Access Code ____ Abbreviated Dial Prgm Group List Access Code ____ Announcement Access Code ____ Answer Back Access Code ____ Auto Alternate Routing AAR Access Code ____ Auto Route Selection ARS Access Code 1 9___ Access Code 2 ____ Automatic Callback Activation ____ Deactivation ____ Call Forwarding Activa...

Page 106: ... Partitioned Group Number _ Percent Full ___ Dialed Total Rte Call Nd ANI Dialed Total Rte Call Nd ANI String Mn Mx Pat Type Num Rq String Mn Mx Pat Type Num Rq 9________________ 7_ 7_ 2__ hnpa ___ n __________________ __ __ ___ ____ ___ _ 976______________ 7_ 7_ den hnpa ___ n __________________ __ __ ___ ____ ___ _ 11_______________ 2_ 2_ 11_ emer ___ n __________________ __ __ ___ ____ ___ _ 91...

Page 107: ..._________________________________ user BCC VALUE TSC CA TSC ITC BCIE Service Feature Numbering LAR 0 1 2 3 4 W Request Format 1 y y y y y n y none_____ both ept outwats bnd____ BAND ___ ________ none 2 y y y y y n n rest _______________ ________ next 3 y y y y y n n rest _______________ ________ rehu 4 y y y y y n n rest _______________ ________ none 5 y y y y y n n rest _______________ ________ n...

Page 108: ...Length fields fill out to your own CAMA numbering plan and press Enter Be sure to cover all extensions 35 At the prompt type change cor number the class of restriction COR to be changed and press Enter Change all CORs that are defined for stations in order to remove any calling party restrictions for 911 calls Page 1 of 3 CAMA NUMBERING E911 FORMAT System CESID Default 5241100______ Ext Ext Total ...

Page 109: ...eded near the terminal and can be placed in the satellite closet or work location CAUTION Observe the following cautions when installing the terminating resistor block 440A4 or 110RA1 12 Never install telephone wiring during a lightning storm Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated wires or terminals unless t...

Page 110: ...une 2004 Terminating Resistor Adapter Figure 56 shows an 8 pin 440A4 terminating resistor adapter The adapter has an 8 wide plug at 1 end a short cord and an 8 wide jack at the opposite end Figure 56 8 Wide Terminating Resistor Adapter 440A4 Figure notes 1 8 wide plug 2 8 wide jack 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 R R C C r910013 RPY 012098 1 2 ...

Page 111: ...in resistors and capacitors The bottom row is designated as the input row and the top and middle rows are designated as the output rows The circuit assembly is mounted on a standard 110A 100 pair mounting base Figure 57 Terminating Resistor Block 110RA1 12 Figure 58 shows the wiring connections for the 110RA1 12 terminal block The TN556D BRI switch port is terminated to bottom row C Figure notes 1...

Page 112: ...ovide signal fanout of the T interface BR851 B or the 367A perform fanout at the work station These adapters support more than 1 ISDN terminal per horizontal 4 pair D inside wire DIW To support multiple horizontal runs a MDF with multiple common rows performs fanout in the satellite closet The 110RA1 12 provides fanout for two horizontal runs and contains the 100 ohm terminating resistor Use this ...

Page 113: ...1 multi point BRI at the work station and is used to fanout transmission and power See Figure 59 Figure 59 Wiring Diagram of BR851 B Figure notes 1 Wire pairs 2 Pin numbers 3 Modular plug male 4 Female 5 T Type adapter BR851 B 4 4 r910017 RPY 012098 4 R R R 8 8 8 4 4 4 T T T 7 7 7 3 3 3 R R R 6 6 6 1 1 1 T T T 5 5 5 1 1 1 R R R 4 4 4 3 3 3 T T T 3 3 3 2 2 2 R R R 2 2 2 2 2 2 T T T 1 1 1 1 1 1 2 2 ...

Page 114: ...es and Additions for Avaya CMC1 Media Gateways June 2004 367A Adapter The 367A adapter provides fanout for up to 7 terminals See Figure 60 Figure 60 Wiring Diagram of 367A Adapter Figure notes 1 Jack 1 2 Jack 2 3 Jack 8 4 367A adapter 3 1 2 8 8 8 7 7 7 6 6 6 5 5 5 4 4 4 3 3 3 2 2 2 1 1 1 4 ...

Page 115: ...es assume 24 AWG 5 0 26 mm2 D Inside Wire DIW Figure 61 Basic Multi point with One Work Location Figure notes 1 S interface source TN556D 2 Terminating resistor 3 Satellite closet 4 Maximum distance from S interface source to work location 1600 feet 488 m 5 Maximum distance from satellite closet to work location 250 feet 76 m 6 System cabinet 7 Terminating endpoint 1 8 Terminating endpoint 2 9 Wor...

Page 116: ...ocks in the purple field to concentrate the analog line pairs 3 Connect an A25D cable between the sneak fuse panel and the terminal block connector associated with the green row in Step 2 4 Install a green label on the terminal block to identify the remote location 5 Administer per Administrator s Guide for Avaya Communication Manager Install Off Premises or Out of Building Stations Out of buildin...

Page 117: ...block in the white field and up to 3 rows connecting blocks in the purple field At the station location a WP 90929 List 1 Concentrator Cable is used There are 8 station appearances on each of the 3 fingers of the concentrator cable crdfobt RPY 012398 1 2 3 3 4 5 5 5 6 6 7 8 9 10 11 Figure notes 1 Locally engineered cables 2 Out of building wiring 3 Multi pair protector units primary protectors wit...

Page 118: ...ors should always be used When the 3 type protector is already installed a separate sneak current protector is required The multi pair protector units and the off premises cabling must be locally engineered Connectorized multi pair protector units female 25 pair connector are recommended Table 23 shows the recommended protectors Figure notes 1 Locally engineered cables 2 Multi pair protector units...

Page 119: ...ectors to use are the 4C3S 75 Enhanced protector and the ITW Linx Enhanced Protector These units provide primary and sneak current protection The 4C3S 75 is equipped with a heat coil for sneak current protection The ITW Linx is equipped with replaceable fuses for sneak current protection The 4C3S 75 is only used with Vintage 14 or newer TN754 circuit packs The 4C3S 75 can be used on all vintages o...

Page 120: ...r RJ21X connectors The ITW Linx Enhanced Protector mounts directly on connecting blocks and requires a separate ground bar The maximum range for out of building digital voice terminals is 3400 feet 1036 m when using 24 AWG 5 0 26 mm2 wire and 2200 feet 670 m when using 26 AWG 4 0 14 mm2 wire The range can extend to 5000 feet 1524 m using 24 AWG 5 0 26 mm2 wire or 4000 feet 1219 m using 26 AWG 4 0 ...

Page 121: ...rea Telecommunications Service WATS trunks The transfer panel provides emergency trunk bypass or power fail transfer for up to 5 incoming CO trunk loops to 5 selected station sets The 808A equipment s Ringer Equivalency Number REN is 1 0 Amp At the MDF the unit is controlled by a connection to a yellow terminal row connecting block in the trunk auxiliary field The unit is controlled by 48 VDC from...

Page 122: ... Two switches are used for each of the 5 circuits switches 1 and 2 are used for circuit 1 switches 3 and 4 are used for circuit 2 and so forth See Table 25 For loop start set the switches to the left For ground start set the switches to the right Figure notes 1 808A emergency transfer panel 2 Circuit start selection switches 3 Trunk identification label 4 25 pair male connector 1 2 3 4 5 6 7 8 9 1...

Page 123: ...s for Telephone Used for Emergency Transfer and as Normal Extension on page 127 6 On the trunk identification label at the bottom of the panel record the trunk line extension and location for each circuit 7 To each voice terminal designated as an emergency terminal attach a label identifying it as such The labels are provided with the unit 8 Check the system for normal operation as follows a Place...

Page 124: ...30 W S TTC2 Tip PBX Trunk Circuit 2 5 S W RTC2 Ring PBX Trunk Circuit 2 31 R BL TTK2 Tip CO Trunk Circuit 2 6 BL R RTK2 Ring CO Trunk Circuit 2 32 R O TLC2 Tip PBX Line Port 2 7 O R RLC2 Ring PBX Line Port 2 33 R G TST2 Tip Emergency Terminal 2 8 G R RST2 Ring Emergency Terminal 2 34 R BR TTC3 Tip PBX Trunk Circuit 3 9 BR R RTC3 Ring PBX Trunk Circuit 3 35 R S TTK3 Tip CO Trunk Circuit 3 10 S R RT...

Page 125: ...e Port 4 41 Y BL TST4 Tip Emergency Terminal 4 16 BL Y RST4 Ring Emergency Terminal 4 42 Y O TTC5 Tip PBX Trunk Circuit 5 17 O Y RTC5 Ring PBX Trunk Circuit 5 43 Y G TTK5 Tip CO Trunk Circuit 5 18 G Y RTK5 Ring CO Trunk Circuit 5 44 Y BR TLC5 Tip PBX Line Port 5 19 BR Y RLC5 Ring PBX Line Port 5 45 Y S TST5 Tip Emergency Terminal 5 20 S Y RST5 Ring Emergency Terminal 5 46 V BL COM1 Common 1 Relay ...

Page 126: ...y field for a telephone used for emergency transfer and as a normal extension Figure notes 1 To network interface circuitry 2 To CO trunk circuit pack 3 To blue or white station distribution field 4 To power transfer unit 5 To control carrier AUX connector TC TK LC ST 1M 1m 2M 2m 3M ALARM MONITORS EM TRANS RELAY PWR ACC PWR 3m 3w TC TK LC ST TC TK LC ST TC TK LC ST TC TK LC ST C O M 1 N O 1 N C 2 ...

Page 127: ... green field to the TK terminals on the yellow emergency transfer row connecting block for each trunk 4 Connect the ST leads on the yellow emergency transfer row connecting block for each emergency transfer telephone to the ST terminal appearance in the yellow trunk auxiliary field The ST terminal leads should be terminated on the following pairs 1 4 7 10 13 16 19 or 22 the first pair of any 3 pai...

Page 128: ...block for each trunk 4 Connect telephone leads from the purple analog line board row connecting block to the LC terminals on the yellow emergency transfer row connecting block for each telephone 5 Connect ST leads on the yellow emergency transfer row connecting block for each emergency transfer telephone to the ST terminal appearance in the purple trunk auxiliary field 6 Connect the ST leads from ...

Page 129: ...ovided with that modem Refer to Table 29 Modem Fields on page 130 while setting up the modem Go to Step 4 to complete the modem administration 2 If no modem is installed skip to step 5 If a U S Robotics Model 839 modem is installed perform the following 3 Use Table 28 to set the 8 option switches on the U S Robotics modem Figure notes 1 Pin 1 of network jack 2 Modem modmcabl KLC 110397 OFF ON AA C...

Page 130: ...P DOWN Auto answer on first ring or higher if specified in NVRAM Auto answer off 6 UP DOWN Carrier detect normal Carrier detect override 7 UP DOWN Load NVRAM defaults Load factory defaults 8 UP DOWN Dumb mode Smart mode Table 29 Modem Fields Field Description Modem Connection Default is none Set to external if a modem is used Modem Name This field is 20 characters long and permits alphanumeric cha...

Page 131: ...provide similar functionality Misc Init Param This field has a 20 character blank default and supports any initialization parameters not already specified The AT commands specified in this field are always the last initialization parameters to be sent to the external modem This field is not case sensitive Auto Answer Ring Number This field controls the number of rings required before the modem ans...

Page 132: ...Installing and Cabling the Cabinets Connect Modem to Telephone Network 132 Installation Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 ...

Page 133: ...ication Manager for data module and other peripheral installation and configuration requirements Alarms and Reporting Resolve Alarms 1 Examine the alarm log Resolve any alarms using Maintenance for Avaya DEFINITY Server CSI 2 Refer to Power Supply LED Indications on page 138 if power supply faults are suspected Enable Alarm Origination to INADS No External Modem Installed or No Alarm Origination t...

Page 134: ...gistering must have switch connectivity through the INADS line an IP address NOTE ART is not accessible from the public internet outside the Avaya intranet firewall 1 At your laptop PC direct your browser to this URL http spiexp1 eng avaya com 8000 cgi bin ART ARTstart cgi You can also save this URL in your Favorites or Bookmarks list The ART User Menu displays 2 Click on the Register a Product bu...

Page 135: ...u have entered matches a Maestro database record the Customer Verification page appears 8 Verify the information in the Customer Name and Customer Address fields NOTE If the information is not what you expected ensure that you entered the customer s FL Sold To number correctly Step 4 above If you entered an incorrect number a Click on the Abort Upgrade Registration Session button at the bottom of ...

Page 136: ...TONE for DTMF dialing PULSE for rotary or pulse dialing 14 In the Alarm Origination field choose DON T CHANGE to leave the product s current alarm origination status unchanged the common choice for upgrades YES to enable alarm origination NO for no alarm origination 15 In the Alarm Destination field choose DON T CHANGE to leave the product s currently administered alarm origination number unchange...

Page 137: ...nected to a digital line circuit pack call any nearby telephone connected to an analog line circuit pack 2 Verify that the dial tone ringing pattern and talk path are acceptable 3 Place a call through the Central Office outside call to any nearby telephone Verify that the dial tone ringing pattern and talk path are acceptable Set Neon Voltage Ring Ping NOTE If the ringing option is set to 50 Hz ne...

Page 138: ...right panel and secure Do not use force Power Supply LED Indications It is not possible to view the alarm log to determine which power unit in a multi cabinet system is defective Use the LEDs on the front of each power unit to determine its state Table 30 shows the LED and alarm conditions Ring voltage and neon bus output do not activate alarm status TN760E Tie Trunk Option Settings The TN760E Tie...

Page 139: ...de Table 31 Signaling Formats for TN760E Mode Type E M Type I Standard unprotected E M Type I Compatible unprotected Protected Type I Compatible Type I Standard Simplex Type V E M Type V E M Type V Revised Table 32 Signaling Type Summary Signaling Type Transmit M Lead Receive E Lead On Hook Off Hook On Hook Off Hook Type I Standard ground battery open1 battery 1 An open circuit is preferred instea...

Page 140: ... channel then set the lower switch setting to either 120 ohms or 75 ohms Table 33 TN760E Option Switch Settings and Administration Installation Situation Preferred Signaling Format E M SMPLX Switch Prot Unprot Switch Administered Port Circumstance To System Far End Collocated DEFINITY E M Type 1 E M Type 1 E M Unprotected Type 1 Compatibl e Standard Compatible Inter Building DEFINITY Protected Typ...

Page 141: ...aya CMC1 Media Gateways 141 June 2004 Figure 70 TN464F GP and TN2464BP Option Settings Figure notes 1 TN464F GP or TN2464BP DS1 E1 Interface 2 Option switch 3 24 32 Channel Selector 4 75 120 ohm Selector ckdm464g KLC 091200 1 S I E M E I E O S M S O 1 2 3 4 S T A T U S O 1 N 2 O 1 N 2 32CH 24CH 120 75 32CH 24CH 120 75 3 4 2 ...

Page 142: ...ent are classified as shown in the following tables Table 35 Lead and Color Designations Cross Connect Pin Color Amphenol Pin Backplane Pin 1 W BL 26 102 2 BL W 01 002 3 W O 27 103 4 O W 02 003 5 W G 28 104 6 G W 03 004 7 W BR 29 105 8 BR W 04 005 9 W SL 30 106 10 SL W 05 006 11 R BL 31 107 12 BL R 06 007 13 R O 32 108 14 O R 07 008 15 R G 33 109 16 G R 08 009 17 R BR 34 110 18 BR R 09 010 19 R SL...

Page 143: ... 203 29 BK SL 40 304 30 SL BK 15 204 31 Y BL 41 305 32 BL Y 16 205 33 Y O 42 306 34 O Y 17 206 35 Y G 43 307 36 G Y 18 207 37 Y BR 44 308 38 BR Y 19 208 39 Y SL 45 309 40 SL Y 20 209 41 V BL 46 310 42 BL V 21 210 43 V O 47 311 44 O V 22 211 45 V G 48 312 46 G V 23 212 47 V BR 49 313 48 BR V 24 213 49 V SL 50 300 50 SL V 25 200 Table 35 Lead and Color Designations Cross Connect Pin Color Amphenol P...

Page 144: ...6 Processor Interface Cable Pinout Signal Name Processor P1 Amphenol Connector AUX J1 TERM J3 DCE J2 Modem P2 ACC48A 40 19 AP1 alarm in 2 26 AP2 alarm in 27 27 EXTALMA 5 48 EXTALMB 30 23 XFER48 38 36 MOD CTS 21 5 MOD DCD 46 8 MOD DSR 8 6 MOD DTR 7 20 MOD GRD 20 1 7 MOD RTS 34 4 MOD RXD 33 3 MOD TXD 45 2 TERM CTS 9 5 TERM DTR 47 20 TERM GRD 35 1 7 TERM RXD 10 3 TERM TXD 22 2 CDR CTS 49 5 CDR DCD 24...

Page 145: ...67E TN464GP TN2207 TN746 B TN2183 TN793B TN2793B TN2224CP 1 T1 T 1 T 1 T 1 T 1 C_5 T 1 T 1 2 R 1 R 1 R 1 R 1 R 1 R 1 R 1 3 TXT 1 T1 1 TXT 1 SZ 1 BT 1 C_ENAB T 2 T 2 4 TXR 1 R1 1 TXR 1 SZ1 1 BR 1 R 2 R 2 5 PXT 1 E 1 PXT 1 S 1 LT 1 C_SYNC T 3 T 3 6 PXR 1 M 1 PXR 1 S1 1 LR 1 R 3 R 3 7 T 2 T 2 T 2 T 2 T 2 C2D DATA T 4 T 4 8 R 2 R 2 R 2 R 2 R 2 RDATA R 4 R 4 9 TXT 2 T1 2 TXT 2 SZ 2 BT 2 TDATA T 5 10 TX...

Page 146: ... PXT 5 E 5 PXT 5 S 5 LT 5 T 11 T 15 30 PXR 5 M 5 PXR 5 S1 5 LR 5 C_RST R 11 R 15 31 T 6 T 6 T 6 T 6 T 6 T 12 T 16 32 R 6 R 6 R 6 R 6 R 6 R 12 R 16 33 TXT 6 T1 6 TXT 6 SZ 6 BT 6 RDATA T 17 34 TXR 6 R1 6 TXR 6 SZ1 6 BR 6 TDATA R 17 35 PXT 6 E 6 PXT 6 S 6 LT 6 TRSYNC T 18 36 PXR 6 M 6 PXR 6 S1 6 LR 6 GRD R 18 37 T 7 T 7 T 7 T 7 T 7 SCLK T 19 38 R 7 R 7 R 7 R 7 R 7 R 19 39 TXT 7 T1 7 TXT 7 SZ 7 BT 7 T...

Page 147: ...6 R 24 49 GRD GRD GRD GRD GRD GRD LBACK2 GRD GRD 50 GRD GRD GRD GRD GRD GRD GRD GRD GRD Table 37 Port Circuit Pack Lead Designations Cross Connect Pin TN742 B TN747B TN753 TN769 TN2147 TN465 TN754C TN726B TN760 B TN760C TN760E TN2209 TN762 B TN763 TN763D TN763C TN735 TN767E TN464GP TN2207 TN746 B TN2183 TN793B TN2793B TN2224CP 3 of 3 Table 38 DS1Interface Cable H600 307 and C6C 50 Pin 15 Pin Pin C...

Page 148: ...TXR 1 2 BL W 01 002 PXT 1 3 W O 27 103 PXR 1 4 O W 02 003 2 TXT 2 5 W G 28 104 TXR 2 6 G W 03 004 PXT 2 7 W BR 29 105 PXR 2 8 BR W 04 005 3 TXT 3 9 W SL 30 106 TXR 3 10 SL W 05 006 PXT 3 11 R BL 31 107 PXR 3 12 BL R 06 007 4 TXT 4 13 R O 32 108 TXR 4 14 O R 07 008 PXT 4 15 R G 33 109 PXR 4 16 G R 08 009 5 TXT 5 17 R BR 34 110 TXR 5 18 BR R 09 010 PXT 5 19 R SL 35 111 PXR 5 20 SL R 10 011 6 TXT 6 2...

Page 149: ... Connect Pin Color Amphenol Pin Backplane Pin 1 T 1 1 W BL 26 102 R 1 2 BL W 01 002 2 T 2 3 W O 27 103 R 2 4 O W 02 003 3 T 3 5 W G 28 104 R 3 6 G W 03 004 4 T 4 7 W BR 29 105 R 4 8 BR W 04 005 5 T 5 9 W SL 30 106 R 5 10 SL W 05 006 6 T 6 11 R BL 31 107 R 6 12 BL R 06 007 7 T 7 13 R O 32 108 R 7 14 O R 07 008 8 T 8 15 R G 33 109 R 8 16 G R 08 009 9 T 9 17 R BR 34 110 R 9 18 BR R 09 010 10 T 10 19 ...

Page 150: ... 204 16 T 16 31 Y BL 41 305 R 16 32 BL Y 16 205 17 T 17 33 Y O 42 306 R 17 34 O Y 17 206 18 T 18 35 Y G 43 307 R 18 36 G Y 18 207 19 T 19 37 Y BR 44 308 R 19 38 BR Y 19 208 20 T 20 39 Y SL 45 309 R 20 40 SL Y 20 209 21 T 21 41 V BL 46 310 R 21 42 BL V 21 210 22 T 22 43 V O 47 311 R 22 44 O V 22 211 23 T 23 45 V G 48 312 R 23 46 G V 23 212 24 T 24 47 V BR 49 313 R 24 48 BR V 24 213 25 49 V SL 50 31...

Page 151: ...ntral Office Trunk 3 Wire Four Port DIOD2 TN467 TN2149 TN726B TN2224 TN762 TN417 TN429D TN2199 TN429D TN478 TN483 TN2184 TN432 TN2135 TN754C TN2214 TN762B TN763 TN493 TN2139 TN458 TN722 TN431 TN468B TN564B TN793 TN763D TN422 TN459B TN449 TN767E TN411B TN448 TN413 TN2793 TN421 TN436B TN760E TN722B TN742 TN746 TN2214CP TN438B TN753B TN760C TN464GP TN769 TN746B TN2224CP TN447 TN2146 TN434 TN2207 TN21...

Page 152: ...1 T1 T1 A1 T1 T1 T1 BL W 01 R1 R1 R1 V1R1 R1 R1 B1 R1 R1 R1 W O 27 T2 TXT1 T2 CT1 SZ1 T11 O W 02 R2 TXR1 R2 CR1 SZ11 R11 W G 28 T3 PXT1 T3 P 1 S1 E1 G W 03 R3 PXR1 R3 P 1 S11 C1 M1 W BR 29 T2 T4 T4 V1T2 T2 T2 A2 T2 T2 T2 BR W 04 R2 R4 R4 V1R2 R2 R2 B2 R2 R2 R2 W S 30 TXT2 T5 CT2 SZ2 T12 S W 05 TXR2 R5 CR2 SZ12 R12 R BL 31 PXT2 T6 P 2 S2 E2 BL R 06 PXR2 R6 P 2 S12 C2 M2 R O 32 T3 T7 V1T3 T3 T3 A3 T...

Page 153: ...16 V1R6 R6 R6 Y O 42 TXT6 T17 CT6 O Y 17 TXR6 R17 CR6 Y G 43 PXT6 T18 P 6 G Y 18 PXR6 R18 P 6 Y BR 44 T7 T19 V1T7 T7 T7 BR Y 19 R7 R19 V1R7 R7 R7 Y S 45 TXT7 T20 CT7 S Y 20 TXR7 R20 CR7 V BL 46 T13 PXT7 T21 P 7 BL V 21 R13 PXR7 R21 P 7 V O 47 T8 T14 T22 V1T8 T8 T8 LI O V 22 R8 R14 R22 V1R8 R8 R8 LI Table 42 Circuit Pack and Auxiliary Equipment Leads Pinout Charts Color Connector Pin Numbers Analog...

Page 154: ...ransmit TX Terminal transmit LI LI Digital Trunk IN LO LO Digital Trunk OUT The following wire colors apply in the above chart W White S Slate Grey BL Blue R Red O Orange BK Black G Green Y Yellow BR Brown V Violet V G 48 T15 TXT8 T23 CT8 LO G V 23 R15 TXR8 R23 CR8 LO V BR 49 T16 PXT8 T24 P 8 LBACK2 BR V 24 R16 PXR8 R24 P 8 LBACK1 V S 50 S V 25 Table 42 Circuit Pack and Auxiliary Equipment Leads P...

Page 155: ...se Files for all switches The License File enables the Avaya Communication Manager category release features and capacities License Files are created using SAP order information and or current customer configuration information Without a license file the switch does not provide normal call processing 7 digit dial plan expansion The upgrade automatically converts the old Uniform Dial Plan forms to ...

Page 156: ...Procedures Releases 6 7 and 8 formatted translation cards are compatible for read only operations New formatted translation cards are shipped with each upgrade Usable Circuit Packs Every port or control circuit pack used in the upgraded system must conform to the minimum usable vintage requirements Those circuit packs must meet the usable vintage specifications Refer to the Software Release Letter...

Page 157: ... for each step Table 43 Tasks List Task Description Page Pre upgrade checklist 158 Check SPE 165 Verify Software Version 165 Verify System Status 165 Disable Scheduled Maintenance and Alarm Origination to INADS 165 Check Link Status 166 Save Translations 166 Save Announcements if necessary 166 Shut Down DEFINITY AUDIX System if necessary 167 Replace Circuit Packs 167 Install the License File 168 D...

Page 158: ... Pre installation checklist Item No Item 1 Software Release Letter 2 Avaya Communication Manager on removable media 3 Extra formatted removable media 4 Authorized wrist grounding strap 5 Documentation book or PDF file Maintenance for Avaya DEFINITY Server CSI Administrator s Guide for Avaya Communication Manager 6 Your personal Single Sign On SSO for RFA website authentication login 7 SAP order nu...

Page 159: ...A https cala businesspartner avaya com mnc index html EMEA https emea businesspartner avaya com APAC http www avaya apac com bp Contractors go to http www avaya com services rfa If you are unable to access RFA using your recommended portal try http rfa avaya com 2 Using your SSO log in to the RFA website 3 Follow the links to the RFA Information page 4 Complete the information necessary to create ...

Page 160: ... FET from your laptop PC to create a Switch Configuration File 2 When prompted type in the Transaction ID number 3 Use the FET instructions to create a new switch connection profile 4 Create the Switch Configuration File 5 Upload the Switch Configuration File to the RFA website 6 Deliver the License File to your laptop PC for installation later in this procedure If you have problems with RFA If yo...

Page 161: ...re access code allows users to print undelivered messages without having to call the message center APAC RTAC Direct and Business Partners 65 6872 8686 CALA Mexico TAC Brazil TAC Columbia TAC Argentina TAC Mexico Call Receipt Direct and Business Partners 525 278 7878 5511 5185 6655 571 616 6077 5411 4114 4440 1 720 444 9998 Table 45 RFA Helpdesk contact numbers Where Who Phone number URL Prompt or...

Page 162: ... Activation Deactivation ISDN Access Code Last Number Dialed Access Code Leave Word Calling Message Retrieval Lock Leave Word Calling Message Retrieval Unlock Leave Word Calling Send A Message 66 Leave Word Calling Cancel A Message 66 Malicious Call Trace Activation Deactivation PASTE Display PBX data on Phone Access Code Personal Station Access PSA Associate Code Per Call CPN Blocking Code Access...

Page 163: ...to Answer none Console Type principal TN 1 Data Module n Port 01C1106 COR 1 Disp Client Redir n Security Code COS 1 Display Language english H 320 Conversion n DIRECT TRUNK GROUP SELECT BUTTON ASSIGNMENTS Trunk Access Codes Local Remote Local Remote Local Remote 1 9 5 9 2 82 6 10 3 7 11 4 8 12 HUNDREDS SELECT BUTTON ASSIGNMENTS 1 print msgs5 9 13 17 2 6 10 14 18 3 7 11 15 19 4 8 12 16 20 change no...

Page 164: ...s are no longer supported and will not work after the upgrade Figure 76 Station form display communication interface processor channels Page 1 of 16 PROCESSOR CHANNEL ASSIGNMENT Proc Gtwy Interface Destination Session Mach Chan Enable Appl To Mode Link Chan Node Port Local Remote ID 1 n audix s 1 5000 audix 0 1 2 2 2 n dcs c 2 5000 default 5000 1 2 4 3 n msaamwl s 3 5000 msa 0 1 2 4 n msahlwc c 4 ...

Page 165: ...that identify the busy outs placed by the customer Restore the customer placed busy outs after you have upgraded the system 3 Execute the following commands and verify that the information is correct list station list trunk group list hunt group list data module list announcements If any command does not complete successfully escalate the problem immediately Disable Scheduled Maintenance and Alarm...

Page 166: ...anslation flashcard which takes about 10 minutes When the save translations is successful the error code must be a zero otherwise the translations are not copied If the translations were corrupted the following error message displays when logging in WARNING Translation corruption detected call Avaya distributor immediately NOTE The save translation command cannot function if translations are corru...

Page 167: ... orange card into the new TN2402 processor circuit pack slot NOTE In most cases the orange card will not be on site and the upgrade performed using the pre loaded Avaya Communication Manager on the TN2402 Processor circuit pack If this is true skip to Step 7 3 Place the TN2402 processor circuit pack into the slot vacated by the TN798 processor 4 Lock the TN2402 processor into place to power up the...

Page 168: ...and the switch 1 Go to the RFA website and following the instructions in the Deliver to G3r G3si G3csi chapter of the RFA Job Aid deliver the License File NOTE This procedure sends the License File to the switch and installs it 2 If the system has IP endpoints registered and you unplugged the Ethernet cable from the TN799 C LAN circuit pack replug the cable This re registers the IP endpoints Insta...

Page 169: ...mber field optional type a valid extension NOTE This number cannot be a hunt group or ACD number 5 Press ENTER to save the changes Display Memory Configuration 1 Log in as craft If the Translation Corruption Detected message appears refer to Translation Corruption Detected on page 334 2 Type display memory configuration and press Enter Make sure that in the Total DRAM field the SIMM field in the S...

Page 170: ...RI resides on the network packet circuit pack For Release 7 and later the only way to determine if an ISDN PRI D Channel is up is to type status signaling group and press Enter 5 Type list signal press Enter For each signal type status signal and press Enter NOTE Check the ISDN PRI D channel links here DAYLIGHT SAVINGS RULES Rule Change Day Month___Date Time____Increment 0 No Daylight Savings 1 St...

Page 171: ...re to get additional help on page 17 for telephone numbers NOTE As part of the system registration process the INADS Database Administrator enables Alarm Origination and customer options Register the Switch for Maintenance The Automatic Registration Tool ART is a web based tool that permits field technicians and TSO Database Administration DBA to register U S direct channel products The product th...

Page 172: ... numbers are typically 7 digits long sometimes beginning with an upper case S followed by two zeros for example S001234567 FL numbers are 10 12 letters or digits 5 In the Session Type field select NEW INSTALL REGISTRATION for products that are initially installed at a customer site UPGRADE REGISTRATION for all subsequent product registrations 6 In the Product Type field choose DEFINITY for the fol...

Page 173: ...ure whether a listed product is the one you want to register contact the DBA group for assistance 1 800 248 1234 selecting prompt 2 prompt 6 then prompt 2 Four new fields appear 12 In the Data Lock field choose YES for products with ASG enabled NO for all others 13 In the Dialing Type field choose the dialing type that the product will use to report alarms DON T CHANGE to leave the product s diali...

Page 174: ... 6 then prompt 2 immediately for assistance 18 Save the DEFINITY Upgrade Registration Report in a file for future reference or print the report and keep the copy Check Customer Options 1 Type display system parameters customer options and press Enter 2 Ensure that the G3 version field is V11 3 If the customer was using Supplementary Services Protocol b or d on an ISDN PRI trunk group before the up...

Page 175: ...l translation card with the new ATA flashcard Save Translations post upgrade 1 Type save translations and press Enter to copy upgraded translations to the new flashcard which takes about 20 minutes Save Announcements if necessary post upgrade 1 Type save announcements and press Enter to copy announcements to the new flashcard Return Equipment 1 Return replaced equipment to Avaya 2 Retain the old t...

Page 176: ... 2 minutes 5 You can now shut down the carrier or remove the AUDIX System for service CAUTION If leaving AUDIX System in the carrier back it out about 2 in 5 cm to eliminate the possibility of damage due to power surges Power Up the AUDIX System If the AUDIX was removed from the cabinet 1 Re install the AUDIX and allow it to power up automatically 2 Check for AUDIX System errors If the AUDIX remai...

Page 177: ...tch does not provide normal call processing 7 digit dial plan expansion The upgrade automatically converts the old Uniform Dial Plan forms to the new forms These forms are discussed completely in the Administrator s Guide for Avaya Communication Manager Customers upgrading to Avaya Communication Manager can migrate to the 6 7 digit dial plan or not Customers who want to migrate to the 6 7 digit di...

Page 178: ...nslation corruption occurs if incompatible software is loaded Also check the Minimum Vintage Table which is included with the letter before starting the upgrade Usable circuit packs Every circuit pack must conform to the minimum usable vintage requirements for that system At a presale site inspection the remediation process checks the vintages of existing circuit packs to be reused Replace all unu...

Page 179: ...st 180 Go to the RFA website 181 Check SPE 187 Verify version 187 Verify system status 187 Disable scheduled maintenance and alarm origination 188 Check link status 188 Save translations 189 Save announcements if necessary 189 Upgrade the software 189 Install the License File 190 Administer no license emergency numbers 191 Set daylight savings rules 191 Verify the upgrade 191 Check link status 192...

Page 180: ...FA website authentication login 7 SAP order number with RTUs 8 Look up hardware serial number s with the list configuration license long SAT command Duplicated systems require long in the command 9 Transaction Record number 10 System Identification SID number 11 Switch telephone number or IP address 12 Access to the RFA Information page for these items depending upon your switch connection method ...

Page 181: ...go to http www avaya com services rfa If you are unable to access RFA using your recommended portal try http rfa avaya com 2 Using your SSO log in to the RFA website 3 Follow the links to the RFA Information page 4 Complete the information necessary to create a License File NOTE If you have problems with a hardware serial number that is not in the SAP database go to the If you have problems with R...

Page 182: ...ction profile 4 Create the Switch Configuration File 5 Upload the Switch Configuration File to the RFA website 6 Deliver the License File to your laptop PC for installation later in this procedure If you have problems with RFA If you get an error message that a hardware serial number is not in the SAP database you must call the RFA Helpdesk Table 49 to have them correct the SAP information Table 4...

Page 183: ...ss Code FAC form Figure 77 This feature access code allows users to print undelivered messages without having to call the message center CALA Mexico TAC Brazil TAC Columbia TAC Argentina TAC Mexico Call Receipt Direct and Business Partners 525 278 7878 5511 5185 6655 571 616 6077 5411 4114 4440 1 720 444 9998 Table 49 RFA Helpdesk contact numbers Where Who Phone number URL Prompt or selection 2 of...

Page 184: ...tivation Deactivation ISDN Access Code Last Number Dialed Access Code Leave Word Calling Message Retrieval Lock Leave Word Calling Message Retrieval Unlock Leave Word Calling Send A Message 66 Leave Word Calling Cancel A Message 66 Malicious Call Trace Activation Deactivation PASTE Display PBX data on Phone Access Code Personal Station Access PSA Associate Code Per Call CPN Blocking Code Access Co...

Page 185: ...1106 COR 1 Disp Client Redir n Security Code COS 1 Display Language english H 320 Conversion n DIRECT TRUNK GROUP SELECT BUTTON ASSIGNMENTS Trunk Access Codes Local Remote Local Remote Local Remote 1 9 5 9 2 82 6 10 3 7 11 4 8 12 HUNDREDS SELECT BUTTON ASSIGNMENTS 1 print msgs5 9 13 17 2 6 10 14 18 3 7 11 15 19 4 8 12 16 20 change node names audix msa Page 1 of x AUDIX MSA NODE NAMES Audix Name IP...

Page 186: ...stration These Multi Button Electronic Telephone MET stations are no longer supported and will not work after the upgrade Figure 82 Station form display communication interface processor channels Page 1 of 16 PROCESSOR CHANNEL ASSIGNMENT Proc Gtwy Interface Destination Session Mach Chan Enable Appl To Mode Link Chan Node Port Local Remote ID 1 n audix s 1 5000 audix 0 1 2 2 2 n dcs c 2 5000 defaul...

Page 187: ...current version listed in the Memory Resident field NOTE Ensure that the current version is compatible with this software only upgrade path from Release 9csi to Avaya Communication Manager Verify system status 1 Type status system 1 and press RETURN Check these fields for the corresponding values In the SPE ALARMS section MAJOR and MINOR alarms 0 Service State in service 2 If there are alarms take...

Page 188: ...t Time field to 21 30 CAUTION If you do not disable Alarm Origination the system can generate alarms resulting in unnecessary trouble tickets 3 Type neither in the Alarm Origination to OSS Numbers field and press ENTER NOTE Disabling alarm origination prevents the system from generating alarms thus preventing unnecessary trouble tickets Check link status 1 Enter display communication interface lin...

Page 189: ... announcements if necessary NOTE The TN750C and the TN2501AP Integrated Announcement circuit packs store announcements in nonvolatile memory saving the announcements to a flashcard is optional 1 If the PPN contains a TN750 B Announcement circuit pack type display announcements and press RETURN 2 If administered recorded announcements are listed type save announcements UUCSS and press RETURN For ex...

Page 190: ... has completely reset before continuing 3 If the system has IP endpoints registered unplug the Ethernet cable from the TN799 C LAN circuit pack This disconnects unregisters all IP endpoints 4 Type set time and press Enter Ensure that the system date and time are set correctly Installation direct connection If you have a direct connection between the RFA and the switch 1 Go to the RFA website and f...

Page 191: ...hunt group or ACD number 5 Press ENTER to save the changes Set daylight savings rules You can set up to 15 customized daylight savings time rules If you have switches in several different time zones you can set up rules for each A daylight savings time rule specifies the exact time when you want to transition to and from daylight savings time and the amount of time offset at the point of transitio...

Page 192: ...essary corrective actions 3 Type list configuration software version and press RETURN The Software Versions screen appears 4 In the UPDATE FILE section check the Update State field for a software patch If there is a patch number then a patch has been applied If the field is none in memory there is no software patch in system memory NOTE If you need to restore the system to the old version you must...

Page 193: ...eb based tool that permits field technicians and TSO Database Administration DBA to register U S direct channel products The product that you are registering must have switch connectivity through the INADS line an IP address NOTE ART is not accessible from the public internet outside the Avaya intranet firewall 1 At your laptop PC direct your browser to this URL http spiexp1 eng avaya com 8000 cgi...

Page 194: ...ATION for all subsequent product registrations 6 In the Product Type field choose DEFINITY for the following products 7 Click on the Start Product Registration button If the data you have entered matches a Maestro database record the Customer Verification page appears 8 Verify the information in the Customer Name and Customer Address fields NOTE If the information is not what you expected ensure t...

Page 195: ...rms DON T CHANGE to leave the product s dialing type unchanged TONE for DTMF dialing PULSE for rotary or pulse dialing 14 In the Alarm Origination field choose DON T CHANGE to leave the product s current alarm origination status unchanged the common choice for upgrades YES to enable alarm origination NO for no alarm origination 15 In the Alarm Destination field choose DON T CHANGE to leave the pro...

Page 196: ...e Restore announcements If the system contains a TN750 B Announcement circuit pack 1 Type restore announcements and press RETURN to copy announcements from the upgraded translation flashcard to memory which takes about 40 minutes Check SPE 1 Type status system 1 and press RETURN Check these fields for the corresponding values In the SPE ALARMS section MAJOR and MINOR alarms 0 Service State in serv...

Page 197: ...it pack code is not present type the code manually in the proper slot 6 Type test board long and press Enter to test the board 7 Log off the system after the addition and any required administration is complete For information about administering circuit packs and other equipment refer to Administrator s Guide for Avaya Communication Manager Upgrade Firmware on Programmable Circuit Packs You can d...

Page 198: ...VAL See Table 51 for each circuit pack s roles in a firmware download Table 51 Programmable Circuit Pack Roles in Firmware Downloads Circuit Pack TN Code Role in Self Download Role in C LAN distributed Download C LAN TN799C1 1 The TN799C C LAN circuit pack can be the source for a C LAN distributed download but cannot be the target circuit pack for either a self or C LAN distributed download becaus...

Page 199: ... Prepare for download The following subsections contain procedures to prepare for the firmware downloads to target circuit packs Verify hardware software requirements on page 199 Get circuit pack information on page 201 Set up source circuit pack s file system on page 202 Verify hardware software requirements Make sure you know which download procedure to use and that you have all the hardware and...

Page 200: ...the target boards 3 Type display fiber link n where n is the fiber link s number and press Enter to access the Fiber Link Administration screen 4 Go to the page 2 and verify that the Line Coding fields are set to b8zs for T1 facilities and hdb3 for E1 facilities If they are not then escalate before proceeding with the firmware download Table 53 Download Method by Circuit Pack Target Circuit Pack s...

Page 201: ...ata module UUC33 and press Enter 7 Determine the IP address of the source circuit pack You can either ask the data systems administrator or type the following commands a Type display ip interfaces Find the source circuit pack s Slot location and write down its Node Name b Type display node names ip Find the source circuit pack s Node Name and write down its IP Address list configuration all SYSTEM...

Page 202: ...re images before downloading them to a TN circuit pack Although the staging area is often on a PC platform you can also use other platforms such as a UNIX or Linux 1 Go to the Avaya Support Web site http avaya com support Follow the Software Firmware Downloads link and the subsequent links for your product and the target circuit pack TN code 2 Find the section for the firmware vintage you want Unl...

Page 203: ...ory where firmware and other files reside This keeps the firmware image file separate from the announcement files f Type put filename ext and press Enter to copy the new firmware image file to the source directory in RAM g Type ls and press Enter to verify that the new firmware image file is on the circuit pack h Type bye and press Enter to end the FTP session Schedule a download to target s You c...

Page 204: ...y disable this schedule using disable firmware download and then start a new one See Aborting a firmware download on page 209 for instructions If you answer n o then the Start Date Time and Stop Date Time fields disappear The download begins as soon as you press Enter Remove Image File After Successful Download Type y if you want the procedure to automatically remove the new firmware image file de...

Page 205: ...ted download enter up to 50 locations these must all be the same type of circuit pack Table 54 Firmware Download fields and descriptions Field Description Notes 3 of 3 change firmware download Page 1 of 1 FIRMWARE DOWNLOAD Source Board Location 01A10 Firmware Image File Name tn2501ap_f05 bin Target Board Code TN2501 Suffix AP Firmware Vintage Schedule Download y Remove Image File After Successful ...

Page 206: ...are download means that there was a problem with a previous firmware download Run the test before proceeding Go to Testing firmware download on page 209 CAUTION Unless the Remove Image File After Successful Download field is set to y the ftplogin and ftppassword remain on the TN799DP or TN799C C LAN and TN2501AP VAL circuit packs either until they are reset or until you type the disable filesystem...

Page 207: ...load field on the Firmware Download screen to y then the download procedure is now complete If you previously set it to n then proceed to the next section Disable file system on page 208 to manually remove the firmware image and disable the file system on the source circuit pack status firmware download Page 1 of 1 STATUS FIRMWARE DOWNLOAD Source Board Location 01C02 Firmware Image File Name usd1v...

Page 208: ... the latch securely 5 Wait until all three of the top LEDs red green and amber are out Disable file system NOTE Performing the following steps on the TN799DP C LAN or TN2501AP VAL circuit packs removes only the ftplogin and the ftppassword The allocated memory for the file system remains reserved for the session To free up resources on the source circuit pack you must delete the new firmware image...

Page 209: ...wnload either before a scheduled download has begun or after an attempted download has reported errors 1 Type test firmware download and press Enter to display the Test Results screen If the download has already begun the test is denied 2 Look in the Result field for FAIL PASS conditions The Result field in the screen shows PASS indicating a successful test of the firmware download circuitry If th...

Page 210: ...ost cases the image with the more recent date and time stamp is the new firmware image file 4 Type set boot image board UUCSS image 1 2 and press Enter Example set boot image board 1C07 image 2 The system responds with Command Successfully Completed 5 Type get boot image UUCSS and press Enter to check the status of the firmware images on the target circuit pack Note that the values in the Reboot I...

Page 211: ...oaded directly to the circuit pack For more information refer to Upgrade Firmware on Programmable Circuit Packs on page 197 The TN464GP and TN2464BP circuit packs are backwards compatible although the echo cancellation feature can only be used with Release 1 1 or later of Avaya Communication Manager and after the feature is enabled The echo cancellation feature cancels echoes with delays up to 96 ...

Page 212: ...y the license file 2 Type add change trunk group next number and press Enter 3 On Trunk Features screen 2 set the DS1 Echo Cancellation field to y 4 Type add change ds1 UUCSS and press Enter add trunk group next Page 2 of 11 SPE A TRUNK FEATURES ACA Assignment n Measured both Internal Alert n Maintenance Tests y Data Restriction n Glare Handling none Used for DCS n Suppress Outpulsing n Seize When...

Page 213: ...r breakup of speech from a distant party It reduces speech clipping but may allow slight residual echo or more background noise 6 Test the voice quality on a telephone connected through the TN464GP or TN2464BP circuit packs and known to have echo to see if the echo was eliminated 7 If the echo still exists set the EC Configuration field to 1 2 or 3 then test the voice quality These settings provid...

Page 214: ...runk Group in Administrator s Guide for Avaya Communication Manager 3 Determine the port assignment of the trunk from the Trunk Group form Add DID Trunks Requirements Two circuit packs presently support Direct Inward Dial DID trunks the TN753 DID trunk circuit pack and the TN797 Combination Circuit pack Each can support up to 8 DID trunks Installation 1 Determine the port assignment of the trunk f...

Page 215: ...ie trunk facilities such as campus environments tie trunk circuit packs provide signaling capabilities beyond those specified by the industry wide E M standard Use Figure 83 Tie Trunk Circuit Packs Component Side on page 215 and Table 55 Tie Trunk Option Switch Settings and Administration on page 216 to choose the preferred signaling format set switches on the circuit pack and administer the port ...

Page 216: ... service may require a service interruption notify the customer in advance as to when the addition will occur 2 For information about administering DS1 Tie Trunks refer to Administrator s Guide for Avaya Communication Manager Table 55 Tie Trunk Option Switch Settings and Administration Installation Situation Preferred Signaling Format E M SMPLX Switch Prot Unprot Switch Administered Port Circumsta...

Page 217: ...ted under Code Calling Access in Administrator s Guide for Avaya Communication Manager Add Pooled Modem Modem pooling supports two types of conversion resources integrated and combined An integrated conversion requires a Pooled Modem circuit pack for each 2 conversion resources provided A combined conversion requires a port of a TN745B or TN2136 Digital Line circuit pack and a port of either an 8 ...

Page 218: ... field 14 Type Full in the Duplex field 15 Type async in the Synchronization field 16 Type the port pair assignments in the Analog and Digital fields and press Enter Settings for Modem Connected to the Data Terminal Equipment DTE 1 Type add station next and press Enter 2 Type 2500 in the Type field 3 Type the port assignment in the Port field and press Enter Add Integrated Announcements TN2501AP R...

Page 219: ...TN2501AP circuit pack Voice Announcement over LAN VAL requires that announcement files are in the following wav formats CCITT A Law or CCITT µ Law companding format do not use PCM 8KHz sample rate 8 bit resolution bits per sample Mono channels 1 All previously recorded announcements must be converted to these file formats to work on the TN2501AP circuit pack Announcements recorded through the dire...

Page 220: ... VAL hardware Figure notes 1 TN2501AP VAL announcement circuit pack 2 System access terminal SAT 3 Switch 4 Phone for recording announcements 5 TN799C C LAN is required when using IP SAT or VAL Manager 6 Your LAN See LAN cable 7 Computer or remote recording studio for Recording and storing announcements FTP client application VAL Manager application PC only 8 Microphone cydfval LJK 032001 1 1 2 3 ...

Page 221: ...re 85 Backplane Adapter Comcode 848525887 LAN cable The TN2501AP circuit pack does not include cables to connect the circuit pack to your LAN The following table lists the cable category and connection port Figure notes 1 Amphenol connector attaches to the back of the switch cabinet corresponding to the TN2501AP circuit pack slot 2 RJ 45 LAN cable connection 10 Mbps uses Category 3 cable 100 Mbps ...

Page 222: ...istration is different you must get a License File with these customer options enabled and install it on the switch before the TN2501AP circuit pack works Hardware installation WARNING To prevent electrostatic discharge ESD be sure to wear a grounding strap while handling the circuit pack 1 Remove connector if any from the back of the switch cabinet corresponding to the TN2501AP circuit pack slot ...

Page 223: ...onfiguration board board location and press RETURN The System Configuration report appears Figure 86 System Configuration screen list configuration board 2 Verify the following field values Board Type shows VAL ANNOUNCEMENT Code is TN2501AP list configuration board 1c08 SPE A SYSTEM CONFIGURATION Board Assigned Ports Number Board Type Code Vintage u unassigned t tti p psa 01C08 VAL ANNOUNCEMENT TN...

Page 224: ...ame on the local network 3 Enter the IP address in the IP Address field You can get this information from the network manager 4 Press ENTER to save the changes change node names ip Page 1 of 1 SPE A IP NODE NAMES Name IP Address Name IP Address Tiki 172 22 22 79 cdr_1 192 168 22 63 default 0 0 0 0 iolan 172 22 22 68 lulu_cl1 172 22 22 71 lulu_cl2 172 22 22 77 riki 172 22 22 20 rsat4 172 31 5 49 rs...

Page 225: ...you press Help a list of administered node names appears including the name you administered with the change node names ip command and you can select from the list 7 Set the Subnet Mask field according to your network requirements 8 The Gateway Address is usually the same as the TN2501AP circuit pack s IP address usually with the fourth octet changed Be sure to set this address according to your n...

Page 226: ... is always 33 for the TN2501AP circuit pack 4 Set the Link field to an unassigned or next available link number 5 Set the Network uses 1 s for Broadcast Address field according to the your network requirements 6 Type a unique name in the Name field 7 Press ENTER to save your changes 8 If your system uses IP routing continue with the add ip route section 9 Otherwise go to the Test the IP connection...

Page 227: ...circuit pack to provide synchronization for the DS1 E1 circuit pack If using a TN464F then packet bus support has not been added requiring more than 8 PRI signaling groups See Add Packet Bus Support on page 228 for adding circuit packs for packet bus support Add Packet Bus Support 1 If packet bus support is not already installed see Add Packet Bus Support on page 228 and perform the steps Add Circ...

Page 228: ...s 3 For some DEFINITY ECS software versions disable Cleared Alarm Notification and Restart Notification before submitting the form Save Translations 1 Type save translation and press Enter This instructs the system to take all translation information in memory and write it to the translation card Install Circuit Packs 1 Install the appropriate TN circuit packs See Table 56 Administer the Bus Bridg...

Page 229: ... press Enter Ensure that the G3 version field is V11 2 If the customer was using Supplementary Services Protocol b or d on an ISDN PRI trunk group before the upgrade go to the QSIG Optional Features screen and ensure that the Basic Call Setup field is y Add CallVisor ASAI Enter Added Translations 1 On the System Parameters Customer Options screen disable the Calling Party Number Billing Number CPN...

Page 230: ...lock circuit pack provides A vacant port is required on a TN556D ISDN BRI circuit pack Install Cables 1 Install cables from TN464GP to the MDF as required Enter Added Translations 1 Administer the required translation data using the forms listed under Adjunct Switch Applications Interface ASAI in Administrator s Guide for Avaya Communication Manager Resolve Alarms 1 Examine the alarm log Resolve a...

Page 231: ...t feature information These data links also called DCS signaling links support the feature transparency DCS requires a special signaling connection to carry the information needed to make the DCS features work This signaling connection or link between two switches in a DCS network is implemented either over an ISDN PRI D channel over a TCP IP connection Meanwhile the data link interface between th...

Page 232: ... a C LAN circuit pack is already in the system you do not need a second C LAN circuit pack for DCS If your system already has a C LAN skip the following Administer the Bus Bridge section You do not need to power down the cabinet to install any of these circuit packs Administer the Bus Bridge 1 Type change system parameters maintenance and press Enter 2 On Page 2 Type y in the PKTINT 2 field 3 Choo...

Page 233: ...tor to the port slot containing the C LAN circuit pack See Figure 90 For a pinout of TN799C see Table 57 TN799C Pinout on page 233 Figure 90 Cable Connection for C LAN Figure notes 1 259A Connector 2 DW8 Cable 3 Hub or 110 purple wall field Table 57 TN799C Pinout Backplane Pin 25 Pair Wire Color Lead Name Peripheral Connector Pin 103 White Orange TD 27 003 Orange White TD 2 104 White Green RD 28 0...

Page 234: ...ket Bus Support 1 If packet bus support is not already installed see Add Packet Bus Support on page 228 and perform the steps Add Circuit Packs 1 Determine port assignment of circuit packs to be added 2 Install the appropriate circuit packs in assigned cabinet slot as required Install Cables 1 Install cables from cabinet to the MDF as required NOTE BRI requires a 12 port backplane cable terminator...

Page 235: ...stomers two of which are Avaya R300 Remote Office Communicator and the IP Media Processor For information on the Avaya R300 refer to the documentation on the CD or with the Avaya R300 equipment The IP Media Processor allows you to send voice and fax from the Avaya CMC1 Media Gateway through an Internet protocol IP network to other switches having this feature or to other H 323 compliant endpoints ...

Page 236: ... you need a TN799DP to download new firmware to the TN2302AP circuit pack The TN2302AP IP Media Processor can work in the same configuration with the TN802 IP Trunking and the TN802B IP Interface Assembly When figuring the maximum number of circuit packs you must include all in your total count NOTE The TN802 IP Trunking cannot talk directly via Ethernet to the TN2302AP IP Media Processor Each TN2...

Page 237: ...ctions on filing a claim 2 If the box is undamaged check the contents against the packing slip Check the condition of each component and note any damage or shortages on the packing slip The carton should contain the items in Table 58 Required Hardware on page 237 for each TN2302AP IP Media Processor ordered 3 Read and follow any directions inserted into the package by the factory NOTE The customer...

Page 238: ... 2 Connect a 259A connector to the backplane connector corresponding to each TN799DP slot 3 Connect one end of each DW8 cable to each 259A connector Connect the cables for TN2302AP 1 Determine into which port slots you are putting the TN2302AP IP Media Processor circuit packs From the rear of the cabinet 2 Connect the Amphenol connector on the adapter to the backplane connector corresponding to ea...

Page 239: ...ack remove it first and replace it with the new TN799DP NOTE To properly seat the circuit pack push firmly on the front of the faceplate until the latch reaches the bottom rail of the carrier Then close the latch until it is fully engaged 1 Insert the TN799DP circuit pack into the port slot identified earlier 2 Insert and latch the TN2302AP IP Media Processor into the port slot you reserved for it...

Page 240: ... NOTE Refer to the Administration for Network Connectivity for Avaya Communication Manager for specific information 1 Log in as craft 2 Type change node names and press Enter 3 On page 2 type in the node names and IP addresses for the TN799B C and the TN2302AP NOTE The customer or design team provides the actual name and address Suggest a generic name and not one tied to the circuit pack ckdfpro1 ...

Page 241: ...ame entered on the Node Name screen In the Subnet Mask field use the default setting unless you are given a different subnet mask In the Gateway Address field use the address you are given or leave blank change node names Page 2 of 6 NODE NAMES Name IP Address Name IP Address clan a1 192 168 1 31 clan b1 192 168 2 31 default 0 0 0 0 mrmedpro1 192 168 1 81 change ip interfaces Page 1 of 2 IP INTERF...

Page 242: ...n nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the TN2302AP IP Media Processor and UUCSS is the cabinet carrier and slot of the TN2302AP IP Media Processor 2 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of the customer s gateway and UUCSS is the cabinet carrier and slot of the TN2302AP IP Media ...

Page 243: ...LCD When MSHUT is in a steady state it is safe to remove the circuit pack 2 Remove the TN799 and TN802 circuit packs Replace the Cables 1 Disconnect the network cable from the Ethernet connection 2 If using a monitor keyboard and mouse a Turn off the monitor and unplug it from the AC outlet b Disconnect the monitor keyboard and mouse from the H600 512 external cable assembly 3 Turn off the modem a...

Page 244: ...onfiguration all and press Enter to verify that the system recognizes the TN2302AP circuit pack Administration 1 Administer the TN799B C C LAN Refer to the Administration for Network Connectivity for Avaya Communication Manager 2 Administer the IP Media Processor which is usually done remotely Call your service representative to start the process 3 Complete the administration and testing Refer to ...

Page 245: ...em NOTE If replacing the existing TN799 circuit pack remove it first and replace it with the TN799C If you have a TN799B you do not need to replace it for the TN2302AP to work You do need a TN799C if you want to be able to download new firmware to the TN2302AP 1 Press the recessed Reset button on the TN802B circuit pack until MSHUT starts flashing on the LCD When MSHUT is in a steady state it is s...

Page 246: ...uit pack 2 For convenience install the TN2302AP circuit pack in the rightmost slot vacated by the TN802B and where the adapter is connected to the corresponding backplane connector The other 2 slots are now available for other circuit packs When you plug in the TN2302AP IP Media Processor the circuit pack starts to boot The RED LED stays on until an IP address is assigned to the circuit pack 3 Typ...

Page 247: ... circuit packs see Upgrade to TN802B R8 on page 271 Prepare for Installation Have the following equipment on site before your shipment arrives AC power outlets for the modem and monitor Three unoccupied and adjoining port slots in the carrier for the TN802B IP Interface if needed The TN802B occupies only one slot but it needs the two slots to its left for clearance An additional unoccupied port sl...

Page 248: ...he packing slip The carton should contain the following for each IP Interface ordered 3 Read and follow any directions inserted into the package by the factory Table 59 Required Hardware Comcode Code Description Quantity 108525528 TN799B C LAN circuit pack One TN799B supports more than one TN802B 1 J58890MA 1 L30 TN802B IP Interface Assembly 1 or more 601939804 H600 512 G1 external cable assembly ...

Page 249: ...02B IP Interface circuit packs NOTE Make sure that at least 3 adjacent slots are free for the TN802B From the rear of the cabinet 2 If adding a new TN799B connect the 259A connector to the backplane connector corresponding to the TN799B slot 3 If adding a new TN799B connect one end of the DW8 cable to the 259A connector Connect the other end to the customer s network 4 Connect the Amphenol connect...

Page 250: ...wn in Figure 94 3 Make sure that the modem s DIP switches are set as shown in Figure 94 External Modem Connections for U S Robotics Modem on page 250 and Table 60 U S Robotics Modem Dip Switch Settings on page 250 4 Plug the modem into an AC power outlet 5 Turn on the modem using the switch on the front of the modem Figure 94 External Modem Connections for U S Robotics Modem Figure notes 1 Connect...

Page 251: ...to power down the carrier to install them If you need to remove the TN802B IP Interface from the carrier at a later time shut down Windows NT first by pressing the recessed reset button on the faceplate see Figure 95 of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min it is safe to remove the circuit pack 4 UP DOWN Echo of...

Page 252: ...rier Then close the latch until it is fully engaged 2 Insert the TN802B IP Interface into the right most of the three slots you reserved for it see Figure 96 and seat it properly When you plug in the TN802B IP Interface Assembly the circuit pack starts to boot and the LCD reads PC Boot The circuit pack reboots automatically and after about 3 to 4 minutes the LCD changes to IPTRK the default mode o...

Page 253: ...53 Figure 96 J58890MA 1 L30 IP Interface Assembly Administer the TN799B C LAN Refer to the Administration for Network Connectivity for Avaya Communication Manager Administer the IP Interface Administration is usually done remotely call your service representative to start the process Administration NOTE Refer to the Administration for Network Connectivity for Avaya Communication Manager for specif...

Page 254: ... the TN802B IP Interface 9 Set the Enabled field to y and press Enter NOTE The customer provides the IP address subnet mask and gateway address At this time the TN802B LCD reads PC BOOT and about 3 to 4 minutes later reads MEDPRO with the asterisk flashing change node names Page 2 of 6 NODE NAMES Name IP Address Name IP Address clan a1 192 168 1 31 clan b1 192 168 2 31 default 0 0 0 0 med a1 192 1...

Page 255: ...ress of the customer s gateway and UUCSS is the cabinet carrier and slot of the TN802B IP Interface 3 Type ping ip address nnn nnn nnn nnn board UUCSS and press Enter The variable nnn nnn nnn nnn is the IP address of another computer beyond the gateway and UUCSS is the cabinet carrier and slot of the TN802B IP Interface The TN802B IP Interface is now installed and connected to the IP network chang...

Page 256: ...nistrator An analog telephone line reserved for the IP Interface diagnostic modem A valid telephone number reserved for the IP Interface diagnostic modem If non U S customer Modem comparable to a U S Robotics Inc Sportster Model USR 33 6 EXT A cable from the modem to the TN802B external cable assembly We recommend that you protect the cabinet where the IP Interface is installed with an uninterrupt...

Page 257: ... Figure 97 TN802B IP Interface External Cable Assembly 3 Read and follow any directions inserted into the package by the factory 601087091 20 ft DB 25 serial cable from modem to TN802B external cable assembly U S customers only 2 1 1 For non U S customers you need a modem comparable to the U S Robotics Sportster and a serial cable Figure notes 1 Amphenol connector to connector corresponding to TN8...

Page 258: ...ow the manufacturer s instructions on connecting the modem 1 Connect the RS232 port of the modem to the MODEM connector of the TN802B external cable assembly NOTE Check the labels near the connectors the MODEM and COM2 connectors look the same 2 Connect an analog telephone line to the leftmost analog line port on the modem as shown in Figure 98 3 Make sure that the modem s DIP switches are set as ...

Page 259: ...bly 4 Plug the monitor into an AC power receptacle and turn it on Connect the Ethernet 1 Connect the network cable to the ETHERNET connector on the TN802B external cable assembly NOTE You need a CAT5 or better cable for 100 Mbyte operation Table 62 U S Robotics Modem Dip Switch Settings Dip Switch Setting Description 1 UP DOWN Data Terminal Ready normal Data Terminal Ready override 2 UP DOWN Verba...

Page 260: ... down the carrier to install it If you need to remove the TN802B IP Interface from the carrier at a later time shut down Windows NT first by pressing the recessed reset button on the faceplate see Figure 99 of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min it is safe to remove the circuit pack Figure 99 TN802B IP Interfa...

Page 261: ...P Interface the circuit pack starts to boot and the LCD reads PC Boot then after about 3 to 4 minutes it changes to IP TRK the default mode Figure 100 J58890MA 1 L30 IP Interface Assembly Test the Modem 1 Check for dial tone 2 Contact Avaya Customer Support and ask a representative to dial into your IP Interface server Administer the IP Interface Administration is done either locally or remotely I...

Page 262: ...r in the User Name field 4 Type iptrunk in the Password field and click OK 5 After logging on for the first time change the administrator password and if desired the user name to ensure security See your Windows NT server documentation for details If administered locally on a monitor keyboard and mouse 1 Press CTRL ALT and DEL simultaneously 2 Type administrator in the User Name field 3 Type iptru...

Page 263: ...k on Start NOTE Do not select Startup After service has started go to the SAT 1 Release the trunk group associated with the IP trunk by typing release board UUCSS and pressing Enter Assign Server and Domain Names The Windows NT server identifies servers using a server name plus a domain name that locates the named server in a particular part of the network The TN802B IP Interface is shipped with g...

Page 264: ...n Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 4 Click the Properties option in the Network window 5 Verify that the Adapter drop down menu lists 2 DEC Ethernet adapters CAUTION Do not change any settings on the adapter labeled 1 for any reason ...

Page 265: ... a valid IP address for the IP Interface server in the IP Address field 8 Type the appropriate subnet mask in the Subnet Mask field NOTE Not all networks require steps 9 through 18 Check with the local network administrator to determine which are required 9 If you use gateways type the IP address of the default gateway for the IP Interface server in the Default Gateway field ...

Page 266: ...pgrades and Additions for Avaya CMC1 Media Gateways June 2004 10 Click on the DNS tab and verify that the domain DNS server is correct 11 Type domain name in the Domain field 12 If using DNS click Add under the DNS Service Search Order field and type its IP address ...

Page 267: ...S file select Enable LMHOSTS Lookup and Import LMHOSTS and click OK 18 If the following dialog box opens click Yes At least one of the adapter cards has an empty primary WINS address Do you want to continue 19 Click the Bindings tab to effect the changes NetBIOS Interface Server and Workstation should now be enabled If any are disabled a red circle with a line through it review the previous networ...

Page 268: ...d 3 Click OK Test the External Connection to the LAN To test the external IP connections ping the IP Interface server and ping a known computer connected to your network 1 Click Start Programs Command Prompt 2 Type ping nnn nnn nnn nnn which is your IP address If everything is configured correctly the system responds with the following message Reply from nnn nnn nnn nnn bytes 32 time ms TTL If no ...

Page 269: ...age Reply from 192 11 13 9 bytes 32 time ms TTL If no response verify the IP address information and check the connectivity including the cabling 3 At the command prompt type ping 192 11 13 8 which is the IP address of the internal processor If you have connectivity the system responds with the following message Reply from 192 11 13 8 bytes 32 time ms TTL If no response verify the IP settings for ...

Page 270: ...aceplate on page 260 of the TN802B IP Interface until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min it is safe to remove the circuit pack 6 After the TN802B is shut down reseat the circuit pack to restart the system 7 Log in using ctrl alt del Upgrading IP trunks to H 323 trunks If there are existing IP trunk connections that you want to upgrade to ...

Page 271: ...a designation the default is D 2 Right click on Start Explore to open the Windows NT Exploring pane and select the drive letter indicated in step 1 3 Double click on Medpro and select the Setup icon 4 Follow the Install Shield procedure to transfer all the necessary files to the TN802 IP Interface NOTE In the Finish dialog box select I will restart later Do not select Restart computer This would b...

Page 272: ...e computer or on the TN802 Press the recessed reset button on the faceplate see Figure 99 TN802B IP Interface faceplate on page 260 until the LCD shows a flashing MSHUT When the flashing stops and the asterisk disappears about 2 min reseat the circuit pack to restart the system or on the SAT a Type busyout board UUCSS and press Enter b Type reset board UUCSS and press Enter c Type release board UU...

Page 273: ...lling an Integrated Channel Service Unit ICSU Module The integrated channel service unit ICSU is a combination of a 120A3A CSU module integrated with a DS1 circuit pack A 700A DS1 loopback jack must be installed with this device Checking for required components The integrated channel service unit ICSU package contains 120A3A CSU module NOTE Re manufactured repaired ICSU units and any manufactured ...

Page 274: ...a TN464E or TN767D or later suffix The enhanced ICSU requires a TN464F or TN767E or later suffix The enhanced ICSU can also be used with the TN2464 or TN2313 Installing the 120A3A CSU Figure 101 120A3A Channel Service Unit Module Figure notes 1 Rear of carrier containing DS1 circuit pack 2 120A3A CSU 3 To 25 pair connector on rear of carrier 4 DW8A DE 4 pair cord to alarm contacts optional 5 4 pai...

Page 275: ...nuity is the 120A3A end The shield is grounded only at the 120A3A end Use the cable provided If cabling other than that provided with the 120A3A is used observe the following guidelines Use 24 gauge wire that provides individually shielded twisted pairs for transmit and receive signals Use the cable between the network interface and the 120A3A Ground the shields of this cable only at the 120A3A en...

Page 276: ...ss the self test troubleshoot the 120A3A as instructed in Integrated CSU Module Installation and Operation 555 230 193 Table 63 provides the H600 383 cable pinouts Table 64 H600 383 Cable Lengths by Group Number on page 276 provides the cable lengths for each cable group number Table 63 H600 383 Cable Pin Assignments Pin Color Channel Service Unit Designation Network Designation Function 1 BK Line...

Page 277: ...for 50 LBS each minimum 3 Install the TOP 2 two screws supplied with the zinc anchors 4 Install the power distribution unit onto the top screws 5 Install the bottom screws through the slots in the power distribution housing Mounting with a backing plate NOTE Note the J58890CG Power Distribution Unit should be installed to the right of the SCC Cabinet Stack and mounted approximately 12 inches 30 5 ...

Page 278: ...102 Switch to adjunct LAN connectivity through a terminal server Installing and administering the terminal server Make sure you have all the equipment on site before the installation You must have the hardware listed in Table 65 Figure notes 1 switch 2 C LAN circuit pack 3 10 100Base T Hub optional 4 terminal server 5 serial port 6 CDR adjunct LAN cydfadj KLC 091302 1 2 5 6 3 DATA CONNECTIONS ONLY...

Page 279: ...l server is 328 feet 100 meters If installed the limit from the terminal server to the adjunct is 50 feet 15 meters However to achieve greater distance limits the switch s LAN hub router may be connected to a WAN and the hub router for the terminal server also connected to the same WAN Cabling diagram Figure 103 shows the connection between the terminal server port and a call accounting system 846...

Page 280: ...e terminal server to communicate only with each other With this connection the and the terminal server should be configured with the same subnet Making the connections Connect the adjunct to the IOLAN using the RJ45 to DB25 cable and the null modem You can use a male female adapter See Figure 104 clan2gca cdr 50 Ft Maximum Standalone Call Accounting Call Accounting Port Demarcation Point M25A or M...

Page 281: ...dem is an important element in this setup Without it data may not transfer correctly 2 Connect the other end of the null modem adapter to the DB25 to RJ45 cable 3 Connect the RJ45 end to any port on the IOLAN Figure notes 1 C LAN circuit pack 2 Local area network LAN 3 IOLAN 104 terminal server 4 Adjunct system management terminal or a system printer for example 5 Null modem 6 PC or laptop for ini...

Page 282: ...ation make sure you have the following information New IP address and subnet mask for IOLAN Host name for IOLAN IP address of Ethernet interface Port number of Ethernet interface where adjunct connects Setting up HyperTerminal on the computer Use the HyperTerminal software program that comes with Windows 95 98 NT 2000 to administer the IOLAN 1 Open HyperTerminal 2 Click on File Properties Connect ...

Page 283: ...more options Name port 2 CONNECTIONS MENU Terminal 2 Connection Host 1 FREE Commands 2 FREE Telnet T 3 FREE Rlogin R 4 FREE Port P Admin mode A CLI Lock Logout D ________________________________________________________________________________ IOLAN PLUS v4 02 00 a CDi iolan Name port 2 ADMINISTRATION MENU Terminal 2 gateway Examine modify gateway table host Examine modify host table line Terminal ...

Page 284: ...e Exit to effect the changes Administrator SERVER CONFIGURATION Terminal 2 Name iolan Debug mode 0 IP address 123 45 67 89 Subnet mask 222 222 0 0 Ethernet address 00 80 d4 03 11 cd Ethernet interface AUTO Language English Identification Lock Disabled Password limit 5 CR to initiate No SNAP encoding Disabled Boot host Boot diagnostics Enabled Boot file Init file MOTD file Domain name Name server N...

Page 285: ...following fields for Entry 1 Destination IP address Gateway Gateway address Netmask Subnet mask NOTE The following steps re initialize the IOLAN so it knows it s connected to the LAN through your gateway 5 Select reboot and press ENTER 6 Press the space bar to restart the IOLAN Administrator ADMINISTRATION MENU Terminal 2 access Remote System Access PPP change Change login and or admin password ga...

Page 286: ...scriptive name Terminal type undef CLI Menu CLI Reset Term No Flow ctrl xon xoff IP addresses leave blank Mask leave blank Access Remote Authentication None Mode Raw Connection None Administrator PORT SETUP MENU Terminal 2 Hardware Flow ctrl Keys Speed 9600 Flow ctrl xon xoff Hot Intr C Parity None Input Flow Enabled Quit Kill U Bit 8 Output Flow Enabled Del Sess Stop 1 Echo Break Disabled IP Addr...

Page 287: ...he system management terminal press ENTER to get the login prompt to the Communication Manager switch NOTE If you get garbled text check the baud rate setting on the Port Setup Menu You can adjust it up or down 2 If no login prompt appears log back into the IOLAN through HyperTerminal 3 Select Admin mode stats and press ENTER twice 4 Select users and press ENTER 5 Look at the port that the adjunct...

Page 288: ...eed to administer 3 Print a copy of this screen or write down the node names you entered You need this information for the next administration task 4 Press ENTER to save your changes change node names ip Page 1 of 1 NODE NAMES Name IP Address Name IP Address 1 switch clan___ 123 456 7 89 17 ______________ ___ ___ ___ ___ 2 callacctg_____ 123 456 9 00 18 ______________ ___ ___ ___ ___ 3 termserver_...

Page 289: ...the PMS application routes through the terminal server termserver is the remote node for this service type 6 In the Remote Port field enter the TCP listen port assigned to the adjunct The recommended value for CDR1 is 5101 and the recommended value for PMS is 5103 NOTE This number must match the port administered on the end device If you are using the Downloadable Reliable Session Layer Protocol t...

Page 290: ...using a printer Administering CDR Data Collection NOTE To send CDR data via CLAN to a device on the LAN WAN you have the option to enable disable RSP 1 Setup the CDR adjunct to be ready to collect CDR data Record the IP address and the port number of the CDR adjunct which could be a terminal server or a CDR application that uses RSP If the CDR adjunct is an application that uses RSP start the appl...

Page 291: ...you were sending data directly to a printer you would use printer 3 In the Primary Output Endpoint field type CDR1 4 If you use a secondary output device and that device is also connected through TCP IP complete the Secondary Output Format field Also type CDR2 in the Secondary Output Endpoint field 5 Press ENTER to save your changes change system parameters cdr Page 1 of 1 CDR SYSTEM PARAMETERS No...

Page 292: ...TT Package Avaya provides this free software application to help vendors and customers develop CDR applications that use the reliable session protocol to collect CDR data from an Avaya Media Server The Reliable Data Transport Tool RDTT is a testing tool and thus is not supported by Avaya Contents of the RDTT The RDTT package consists of the following Specifications for the Reliable Session Protoco...

Page 293: ... computer It is approximately 1 6 to 2 0 MB Installing RDTT To install the RDTT 1 Double click the RDTT exe file The Install Shield Wizard steps you through the installation 2 When prompted to select Client or Server select both programs 3 Continue with the installation Use the default destination folder and program folder Administering RDTT See the instructions in the user_guide doc file to admin...

Page 294: ...ed feet See Figure 105 The maximum distance depends on the type of cable and type of endpoint Figure 105 Typical nonsignaling wideband configuration If using a CSU the distance between connections may be up to 1300 ft 397 2 m The maximum distance to the endpoint depends on the type of cable and the specifications of the endpoint Figure notes 1 Wideband endpoint wire per manufacturer 2 Modular cord...

Page 295: ...k connects to the receive connection on the bandwidth controller and a transmit signal from the bandwidth controller connects to the receive connection on the DS1 E1 circuit pack For CSU installations cross the transmit and receive lines between the CSU and the bandwidth controller Figure 107 shows a remote port module In this configuration there can be considerable distance between the bandwidth ...

Page 296: ...onnection on the TN464GP 2 For CSU installations cross the transmit and receive lines between the CSU and the bandwidth controller Install multimedia call handling MMCH MMCH provides a single point to point conference call using voice video and data from one endpoint to another The customer must have endpoints and a personal computer with H 320 desktop video installed Connect the endpoints Use the...

Page 297: ...the Multimedia Call Handling MMCH field on page 2 of the customer options form must be changed to y 2 Logoff the terminal and then log back on the terminal to see your changes Administer the endpoints 1 Log in and enter add data next or a valid extension number 2 The data module form appears On page 1 of the form enter the Data Extension xxxx Type 7500 the Name user s name such as ProShare and ent...

Page 298: ... H 320 video conference Each person in the conference must have endpoints and a personal computer with the H 320 video application installed The Avaya Media Server must have the expansion service module installed Figure 109 Typical multimedia call handling ESM connections ESM installation Use the following procedure and Figure 109 to connect to the ESM equipment 1 Install the TN2207 primary rate i...

Page 299: ... field to 1 11 Set the Protocol Version field to a 12 Set the CRC field to y 13 The Idle Code default is 11111111 14 The DCP Analog Bearer Capability default is 3 1 kHz 15 Set the MMI Cabling Board field to xxxxx where xxxxx is the location of the TN787F H J K MMI circuit pack recorded in step 2 This must be the slot for port B of the Y cable 16 The MMI Interface field ESM appears 17 Enter add sig...

Page 300: ...chronous TCP IP links and a terminal server This section provides information on connecting adjuncts to the C LAN and providing the initial administration Task list Whether you use an end to end TCP IP configuration a terminal server or a PC running RSP you must complete the following tasks Administering IP node names on page 288 Administering IP services on page 289 Administering adjunct paramete...

Page 301: ...ee this link as active Using the downloadable reliable session layer protocol RSP tool The intent of the Reliable Session Layer Protocol RSP is to guarantee delivery of data records from the switch to an output device that connects to the switch over an asynchronous TCP IP link The Downloadable RDTT tool allows you to implement this protocol on a PC that collects data records in a file The protoco...

Page 302: ...ries with the DS1 span See Figure 110 through Figure 114 2 Plug the H600 383 cable from the ICSU into the female connector on the loopback jack 3 Plug the male connector on the loopback jack cable into the network interface point NOTE Do not remove the loopback jack after installation This is not a test tool and should always be available to remotely test a DS1 span Without a smart jack Install th...

Page 303: ... first two sections are your responsibility The last is the responsibility of the DS1 service provider Testing the DS1 span from the ICSU to the loopback jack The DS1 span test has 2 parts Checking for circuit connectivity The first part of the test powers up the loopback jack and sends a signal from the DS1 circuit pack through the wiring to the loopback jack The test allows about 10 seconds for ...

Page 304: ...jack where UU is the cabinet number C is the carrier letter and SS is the slot number of the DS1 board The loopback jack powers up Active DS1 facility alarms if any clear After about 20 seconds the first set of results appears on the terminal 2 If FAIL appears on the terminal display there may be a fault in the wiring between the ICSU and the loopback jack or the loopback jack may itself be faulty...

Page 305: ... board Table 66 DS1 Troubleshooting Condition Solution The value of the Test cpe loopback jack field is Pattern 3 in 24 The loopback jack test is active The value of the Synchronized field is N Retry the test 5 times The value of the Synchronized field remains N after 5 tries Excessive bit errors are likely Check for intermittent connections or broken wires in an SPE receive or transmit pair and r...

Page 306: ...or count field is 1 The test passed Condition Solution Loopback termination fails with an error code of 1313 The span is still looped somewhere possibly at the loopback jack at the ICSU or somewhere in the network The red LED on the loopback jack is on Replace the ICSU and re run the test Loopback termination still fails Replace the DS1 circuit pack and repeat the test The DS1 cannot frame on the ...

Page 307: ...3 figures using a loopback that overlaps this section of the span Have the DS1 service provider at the CO end run a local ICSU line loopback test Have the DS1 service provider at the CO end run a local DS1 payload loopback test Run a far end ICSU line loopback using the procedure below NOTE This test cannot isolate the problem if there are problems in the wiring between the far end CO and the far ...

Page 308: ...ys June 2004 Figure 110 Network interface at smart jack for a 120A2 or later ICSU Figure notes 1 Span section 1 2 Span section 2 3 Span section 3 4 120A2 or later ICSU 5 RJ 48 to network interface up to 1000 ft 305 m 6 Loopback jack 7 Network interface smart jack 8 Interface termination or fiber multiplexer MUX 9 Central office ...

Page 309: ...face at extended demarcation point smart jack inaccessible for a 120A2 or later ICSU Figure notes 1 Span section 1 2 Span section 2 3 Span section 3 4 120A2 or later ICSU 5 RJ 48 to network interface up to 1000 ft 305 m 6 Loopback jack 7 Dumb block extended demarcation 8 Network interface smart jack 9 Interface termination or fiber multiplexer MUX 10 Central office ...

Page 310: ... demarcation point smart jack accessible for a 120A2 or later ICSU Figure notes 1 Span section 1 2 Span section 2 3 Span section 3 4 120A2 or later ICSU 5 RJ 48 to network interface up to 1000 ft 305 m 6 Dumb block extended demarcation 7 Loopback jack 8 Network interface smart jack 9 Interface termination or fiber multiplexer MUX 10 Central office 11 Dumb block to smart jack RJ 48 ...

Page 311: ... Section 2 includes the short cable from the loopback jack to the dumb block demarcation point part of the loopback jack This cable is the only part of Section 2 that is part of customer premises wiring It is not covered in the loopback jack s loopback path See Figure 113 and Figure 114 Figure 113 Network interface at dumb block for a 120A2 or later ICSU Figure notes 1 Span section 1 2 Span sectio...

Page 312: ...block to CO wiring section 2 in Figure 113 and Figure 114 This can be done using a loopback that overlaps the section of the span Any of the following loopbacks can do this The local ICSU s line loopback which the DS1 service provider at the CO end typically activates tests and then deactivates The local DS1 interface s payload loopback which the DS1 service provider at the CO end activates and te...

Page 313: ...s 3 If the far end ICSU line loopback test failed inform the DS1 provider 4 Request that the DS1 provider perform a loopback test of their portion of the Section 2 wiring by sending someone out to loop Section 2 back to the CO at the dumb block If this test fails the problem is in the service provider s wiring If the test passes the problem is in the cable between the loopback jack and the dumb bl...

Page 314: ...ould read 0 zero volts DC For pin numbers and pin designations refer to Integrated Channel Service Unit ICSU Installation and Operation Install ISDN converters and adapters This section provides information on ISDN converters and adapters that are sometimes necessary when connecting to coaxial facilities in either a multicarrier cabinet or a single carrier cabinet Connections include Integated Ser...

Page 315: ...lug the PC into the RS 232 connector on the front of the PRI converter circuit pack 2 Connect the coaxial Y cable from the TN464GP to the PRI converter circuit pack 3 Connect the opposite end of the Y cable to the 888B coaxial converter Figure notes 1 To TN464GP DS1 circuit pack and either a CSCC 1 PRI to DASS converter or a CSCC 2 PRI to DPNSS converter circuit pack 2 Communication Manager admini...

Page 316: ...t the Communication Manager administration PC to the RS 232 connector on the front of the PRI converter circuit pack Figure notes 1 To TN464GP DS1 circuit pack and PRI to BRI converter circuit pack 2 Communication Manager administration PC 3 RS 232 cable to front of converter circuit pack 4 888B coaxial converter 5 Coaxial connection to 2 Mbps facility 6 Coaxial cable from PRI converter circuit pa...

Page 317: ...onverter cabling PRI to BRI converter Figure 118 shows typical connections from the PRI to BRI converter to the coaxial facility The Communication Manager administration PC is connected to the RS 232 connector on the front of the PRI converter circuit pack Figure notes 1 To TN464GP DS1 circuit pack and either a CSCC 1 PRI to DASS converter or a CSCC 2 PRI to DPNSS converter circuit pack 2 Communic...

Page 318: ...al Coupler Installation Instructions which is normally shipped with the 909A 909B Universal Coupler NOTE If the music source is registered by the FCC in the USA or an equivalent body the 909A B universal coupler is not required Figure notes 1 TN464GP DS1 circuit pack and PR to BRI converter circuit pack 2 Communication Manager administration PC 3 RS 232 cable to front of converter circuit pack 4 8...

Page 319: ...ic source Output impedance 8 ohms 1 5 kΩ and 50 kΩ This switch only requires setting if the Protection Paging switch is set to C2 and the coupler is supplying background music to a customer supplied paging amplifier The pinouts for J1 J2 and J3 are provided in Table 67 Table 68 and Table 69 Refer to these tables when connecting music or paging equipment Figure notes 1 909A B universal coupler 2 J1...

Page 320: ...onnected to S1 lead from the AUX trunk 7 White Brown BSY1 BY1 Busy busy out lead connected to S lead from the AUX trunk 8 Brown Not Used Table 68 J2 Pin Assignments Accessory Connections Pin Color Designation Description 1 White Orange CMS1 M1 Customer supplied music source 2 Orange CMS2 M2 Customer supplied music source 3 White Green COS1 Remote busy out control contact closure from music source ...

Page 321: ...ects directly to the tip and ring connections of a TN763 D auxiliary trunk circuit pack See Figure 121 The 909A B universal coupler provides seizure control to the recorder Table 69 J3 Pin Assignments Power Connections Pin Color Designation Description 1 3 4 7 Not used 2 Black GRD 48 RET or ground lead from system or from positive lead of power supply 5 Yellow 48 VDC 48 VDC from system or from neg...

Page 322: ...iary trunk circuit pack J1 on the 909A B b CBS1 C1 and CBS2 C2 connect from the voice recorder to J2 on the 909A B 4 On the 909A B universal coupler a Connect seizure control voltage of from 9 to 70 Volts to the PG2 BZ2 connection pin 2 of J1 Switching voltage to the PG2 BZ2 connection can be from the 909A B 48 VDC supply b Connect SZ1 to the ground lead of the DC power source used for PG2 BZ2 c S...

Page 323: ...usic source is not FCC registered or equivalent Local music on hold allows one music source However if you purchase the multiple music on hold tenant partitioning feature you can have up to 100 music sources NOTE Use the following connection instructions when the music source is not located in the equipment room If the music source is located in the equipment room do not route the connections thro...

Page 324: ...rce according to the manufacturer s instructions 3 Connect a cable from the assigned port carrier slot to J1 on the 909A B universal coupler see Install 909A B universal coupler on page 318 A wiring block must be locally engineered a Connect the T lead at pin 5 and the R lead at pin 4 of J1 on the 909A B universal coupler to the corresponding leads from the TN2183 b Connect the CT lead at pin 5 an...

Page 325: ...teway Figure notes 1 Customer supplied music source 2 A25D 25 pair cable to auxiliary trunk circuit pack 3 909A B universal coupler 4 Part of main distribution frame 5 Power supply for universal coupler 6 103A or modular wall jack 7 4 pair modular cord 8 Tip and ring wires Figure notes 1 Customer supplied music source 2 25 pair cable to analog line circuit pack 3 909A B universal coupler 4 Part of...

Page 326: ...aker paging feature provides a connection from a TN763B C D auxiliary trunk circuit pack or equivalent to a customer supplied paging amplifier Loudspeaker paging without paging adapter Figure 125 shows the connections for the loudspeaker paging feature These connections are used when the loudspeaker interface equipment is not located in the equipment room If the equipment is located in the equipme...

Page 327: ...y engineered wiring block place a strap between terminals S and SZ Place a strap between terminals S1 and SZ1 4 Install patch cord jumper wires at the main distribution frame 5 Connect a 2 pair line cord modular plug at one end from the information outlet to the paging amplifier to the loudspeaker system 6 Install loudspeaker equipment according to the manufacturer s instructions 7 Administer the ...

Page 328: ...versal coupler on page 318 provides details of the connections between the 909A B universal coupler and the wiring blocks CAUTION Damage to the 909A B may occur if the cable is plugged into J3 before all cross connects are completed 5 On the 909A B universal coupler Connect seizure control voltage of from 9 to 70 volts to the PG2 BZ2 connection pin 2 of J1 Switching voltage to the PG2 BZ2 connecti...

Page 329: ...l ringing are at an information outlet The system side of the main distribution frame MDF is connected to a TN2183 or equivalent analog line circuit pack in an MCC1 SCC1 or CMC1 Media Gateway NOTE Up to three devices can be connected to one analog line circuit pack port 1 Wire the ringing device to the information outlet 2 Administer the switch for the new equipment Figure notes 1 DCP telephone 2 ...

Page 330: ...all Management System CMS R3V11 Software Installation Maintenance and Troubleshooting Guide 585 215 117 Avaya Call Management System CMS Sun Enterprise 3000 and SPARCserver Computers Hardware Maintenance and Troubleshooting 585 214 016 Avaya Call Management System CMS Sun Enterprise 3500 Computer Hardware Installation Maintenance and Troubleshooting 585 215 873 Avaya Call Management System CMS Sun...

Page 331: ...inistration which is available at http avaya com support Click the following links Support Technical Database Contact Centers CRM CTI CVLAN Server for Linux R9 Avaya Interactive Response For information on installing Avaya Interactive Response systems see Avaya Interactive Response R1 2 1 Install and Troubleshooting Guide 07 300180 on the Avaya Interactive Response R1 2 1 Documentation CD 07 30018...

Page 332: ...Adding or Removing Hardware Other adjunct installation information sources 332 Installation Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 ...

Page 333: ...ecific troubleshooting procedures for common upgrade problems Troubleshooting Guidelines Before escalating a problem try the troubleshooting procedures listed in this appendix Also try the general troubleshooting procedures below 1 Check the software compatibility on the Software Release Letter Be sure the software that you are upgrading from is compatible with the Avaya Communication Manager that...

Page 334: ...e fails escalate the problem Translation Corruption Detected This usually means that the translations were not successfully backed up to the translation card or that the current software may not be compatible with the new Avaya Communication Manager Unsuccessful Translation Backup 1 If the processor circuit pack was replaced as part of the upgrade remove the processor and replace it with the origi...

Page 335: ... that you entered earlier 3 Type change communication interface links and press Enter 4 Type the information in the fields based on the information that you entered earlier with one exception Leave the Enable field setting as it is 5 Type change communication interface processor channels and press Enter 6 Type the information in the fields based on the information that you entered earlier 7 Type c...

Page 336: ...Troubleshooting an Upgrade Troubleshooting Upgrades 336 Installation Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 ...

Page 337: ...file without the asg Your login ID is the same as your Avaya login or an abbreviated part of it 3 Type the password twice Note that the password is case sensitive NOTE Your new password will be sent to you in a separate email 4 Click the OK button and an ASG Mobile V1 1 Authentication window appears 5 Use your communications package for example DSA ProComm or TerraNova to dial the switch you need ...

Page 338: ...ays Started and the Response field displays a new seven digit number 13 Move to your communications package window 14 Type the new seven digit response number in the Response field Do not use the character The Avaya CMC1 Media Gateway verifies the response If the response is incorrect return to Step 1 If this is the third rejection see the Maintenance for Avaya DEFINITY Server CSI ...

Page 339: ...B2 82 BR851 B 113 multipoint 112 TN2302AP Amphenol Adapter 238 TN2302AP Amphenol adapter 238 add CallVisor ASAI 229 circuit packs 197 CO trunk 214 216 code calling access 217 DCS Interface 231 DID trunk 214 DS1 tie trunk 216 FX trunk 214 216 IP Solutions 235 ISDN BRI 234 ISDN mBRI 234 ISDN PRI 227 OPS trunk 216 PCOL trunk 214 pooled modem 217 radio controller 235 speech synthesis 217 tie trunk 215...

Page 340: ... C LAN administration 240 test external connection to LAN 242 TN799C 231 with DCS 231 with IP Media Processor 236 CLAN firmware download 197 C LAN distributed firmware download 197 procedure 199 CO trunk wiring 76 CO trunk add 214 216 coaxial converter 888B 315 code calling access add 217 comcodes 26 commercial AC power 37 connecting AC power 36 connections ITS network 238 251 253 259 connections ...

Page 341: ...9 self download 197 source 197 target 197 testing 209 troubleshooting downloads 209 uploading image files from Web 202 flash memory firmware downloads 197 France country code 70 FTP setting up circuit pack to receive files 202 used in firmware downloads 202 FX trunk add 214 216 G Germany country code 69 Greece country code 69 ground approved floor 38 building steel 37 concrete encased 38 ring 38 w...

Page 342: ...number 21 158 License Installation Tool LIT 22 67 158 168 180 190 log in to system 68 loopback jack 301 administration 303 installation 302 M M T ANL TN771DP circuit packs firmware downloads 197 Macedonia country code 70 main distribution frame MDF 329 maintenance test circuit pack M T ANL firmware downloads 197 major alarm contact 101 malicious call trace MCT 321 MDF mounting 47 Mexico country co...

Page 343: ...wer supplies for telephones 1151A1 48V 99 1151A2 48V 99 installing and wiring 81 P333T PWR 96 testing 91 power up AC powered system procedure 66 67 AUDIX procedure 176 printers TCP IP connections 300 procedures return equipment 175 Processor Interface cable connection 44 52 101 pinout 144 Processor serial number 21 158 Programmable circuit pack TN2302AP 235 Q queue warning indicator 330 R radio co...

Page 344: ...N2214CP firmware downloads 197 TN2224 Digital Line 145 151 TN2224CP firmware downloads 197 TN2302 circuit packs firmware downloads 197 TN2302AP Amphenol Adapter 238 TN2302AP Amphenol adapter 238 TN2302AP IP Media Processor installing 236 TN2313AP circuit packs firmware downloads 197 TN2402 Processor 66 67 TN2464 circuit pack option settings 140 TN2464BP circuit packs firmware downloads 197 TN2501A...

Page 345: ...ownloads 197 voice terminals see phones W wall mounting plates 89 Warning meaning of 16 WATS trunk add 214 216 Web links Avaya Support site 202 firmware downloads 202 wideband endpoints non signaling 294 remote port module 295 signaling 295 wiring 1146B power distribution unit 91 2 wire digital station 76 analog station 76 analog tie trunk 77 battery 89 CO trunk 76 digital tie trunk 77 pin designa...

Page 346: ...Index W 346 Installation Upgrades and Additions for Avaya CMC1 Media Gateways June 2004 ...

Reviews: