Upgrading R6csi/R7csi/R8csi to Avaya Communication Manager on an Avaya DEFINITY Server CSI
Task Table
Installation, Upgrades and Additions for Avaya CMC1 Media Gateways
169
June 2004
Administer No-License/Emergency Numbers
1
At the SAT type change system-parameters features and press RETURN.
The Feature-Related System Parameters screen displays:
2
In the
Emergency Numbers - Internal
field (optional) type a valid extension.
NOTE:
This number cannot be a hunt group or ACD number.
3
In the
Emergency Number - External
field (required) type a 21-digit, dialpad-valid character
string that can include trunk access codes. The default for this field is 911.
4
In the
No-License Incoming Call Number
field (optional) type a valid extension.
NOTE:
This number cannot be a hunt group or ACD number.
5
Press ENTER to save the changes.
Display Memory-Configuration
1
Log in as craft. If the
Translation Corruption Detected
message appears, refer to
Translation Corruption Detected
on page 334.
2
Type display memory-configuration and press Enter. Make sure that in the
Total
DRAM
field
the
SIMM
field in the
SPE-A
column says 16.
Set Daylight Savings Rules
You can set up to 15 customized daylight savings time rules. If you have switches in several different
time zones, you can set up rules for each. A daylight savings time rule specifies the exact time when you
want to transition to and from daylight savings time. It also specifies the increment at which to transition.
NOTE:
The default daylight savings rule is 0, no daylight savings.
1
Type change daylight-savings-rules and press Enter.