Slot Zone-1 Zone-2 Zone-3 Zone-4 Zone-5 Highest Lowest Alarm Shutdown
Temp Temp Temp Temp Temp Temp Temp Threshold Threshold
1 37 25 -- 31 24 37 24 54 59
2 34 25 -- 30 23 34 23 54 59
4 33 29 39 36 45 45 29 69 74
8 35 30 38 36 43 43 30 69 74
10 34 34 41 38 47 47 34 69 74
12 35 29 34 35 30 35 29 59 64
SF1 33 -- -- 40 -- 40 33 54 59
SF2 32 -- -- 36 -- 36 32 54 59
SF3 30 -- -- 31 -- 31 30 54 59
SF4 29 -- -- 31 -- 31 29 54 59
SF5 31 -- -- 36 -- 36 31 54 59
The following example displays additional command output that appears for second generation I/O
modules.
Extended Temperature Zones :
Sensor Temperatures
Slot Zone Slice-1 Slice-2 Slice-3 Highest Lowest Alarm Shutdown
1 2 3 1 2 3 1 2 3 Temp Temp Threshold Threshold
4 FPGA 56 51 56 56 55 59 54 47 62 62 47 90 95
4 FA 41 -- -- 49 -- -- 66 -- -- 66 41 105 110
8 FPGA 58 53 57 55 55 51 53 51 51 58 51 90 95
8 FA 37 -- -- 53 -- -- 70 -- -- 70 37 105 110
10 FPGA 53 51 51 55 57 59 57 57 53 59 51 90 95
10 FA 41 -- -- 49 -- -- 64 -- -- 64 41 105 110
The following table describes the output for the
show sys-info temperature
command.
Value
Description
Temperature Info
Zones 1 through 3
Specifies the inlet sensors on the module.
Zones 4 and 5
Specifies the outlet sensors on the module.
Highest Temp
Specifies the highest temperature reached on the
slot.
Lowest Temp
Specifies the lowest temperature reached on the
slot.
Alarm Threshold
Specifies the temperature, when exceeded by one
degree, that causes the system to initiate an SNMP
trap and causes the module online LED to display as
blinking and red.
Shutdown Threshold
Specifies the temperature, when exceeded by one
degree, that causes the system to shutdown the
module by removing power from the slot.
Extended Temperature Zones
This information applies only to second generation modules.
FPGA
Specifies the temperature of the FPGA sensors. A
value of -- indicates that this sensor is not available
on this slot.
Table continues…
Cooling module fundamentals
36
Installing Cooling Modules in Avaya VSP 9000
March 2015