Use the following table to understand the heat sensors in the preceding I/O modules for first
generation and second generation modules.
Table 6: Zone to heat sensor mapping for first generation .and second generation I/O modules
Zones
Heat sensors
zone 1
address 90
zone 2
address 92
zone 3
address 98
zone 4
address 94
zone 5
address 96
The system monitors the temperature every 30 seconds and displays the temperature on all the
modules with the following command:
show sys-info temperature
Note:
The I/O module alarm threshold and shutdown threshold temperatures differ for the Virtual
Services Platform 9010 and the Virtual Services Platform 9012.
The following example shows command output for both first and second generation I/O modules.
Switch:1#show sys-info temperature
Temperature Info :
Slot Zone-1 Zone-2 Zone-3 Zone-4 Zone-5 Highest Lowest Alarm Shutdown
Temp Temp Temp Temp Temp Temp Temp Threshold Threshold
Virtual Services Platform 9010
March 2015
Installing Cooling Modules in Avaya VSP 9000
17