Table 2: Cooling module dimensions
Width
Length
Depth
Weight
9010CM cooling
module
16.5 inches
24 inches
2.125 inches
20 pounds
(419.1 millimeters)
(609.6 millimeters)
(54 millimeters)
(9.07 kilograms)
Front panel LED for the 9010CM cooling module
The 9010CM cooling module for the Virtual Services Platform 9010 provides a single, multicolored
LED on the front panel to indicate the fan status. The following table provides a description of the
LED colors.
Table 3: 9010CM cooling module LED status
LED color
Status
Description
Green
Normal operation
All four fans are operational and spinning at the programmed
rate.
Amber
Powering up
An amber light appears in the following situations:
• The cooling module was just inserted and is powering up.
• The controller is initializing and waiting for the Control
Processor (CP) to take control of the module.
• The Control Processor has lost communication to the fan.
Note:
A flashing amber light can appear when the cooling module
fans have not reached the programmed speed.
Red
Fault
One or more fans are not functioning properly.
Note:
During a hot swap installation, a red LED briefly appears
until the fans reach programmed speed. The LED then
flashes amber for about 15 seconds before it turns green.
Flashing red
Maintenance
The LED flashes red after the service button has been pressed
for 3 seconds to indicate that you can remove the cooling
module.
Important:
The fans do not spin down completely at this point due to
the spinning fans of the companion cooling module. You
have 15 seconds to remove the cooling module before the
fans begin to spin back up. The LED flashes faster when
only 5 seconds remains.
Off
Fault
There is no power to the controller or the controller module has
failed.
Cooling module fundamentals
12
Installing Cooling Modules in Avaya VSP 9000
March 2015