Modules on the VSP
9012
Module LED color
Alarm threshold
Shutdown threshold
Second generation I/O module sensors
Inlet and outlet sensors
Blinking red
69 °C
At 70 °C, the system
triggers the alarm when
the module exceeds the
alarm threshold by one
degree.
74 °C
At 75 °C, the system
shuts down the module
when the module
exceeds the shutdown
threshold by one degree.
Green
Alarm clears after the
temperatures of the
modules are at 68 °C.
—
Field Programmable Gate
Array (FPGA) sensors
Blinking red
90 °C
At 91 °C, the system
triggers the alarm when
the module exceeds the
alarm threshold by one
degree.
95 °C
At 96 °C, the system
shuts down the module
when the module
exceeds the shutdown
threshold by one degree.
Green
Alarm clears after the
temperatures of the
modules are at 89 °C.
—
Fabric Adapter (FA)
sensors
Blinking red
105°C
At 106°C, the system
triggers the alarm when
the module exceeds the
alarm threshold by one
degree.
110°C
At 111°C, the system
shuts down the module
when the module
exceeds the shutdown
threshold by one degree.
Green
Alarm clears after the
temperatures of the
modules are at 104°C.
—
Bringing the module online
If a module shuts down due to heat, you must intervene to bring the slot back online. After you
correct the temperature issue and the heat condition clears, you must bring the module back online.
The module does not go online again unless you re-enable the module. After CP, SF, or I/O
modules shut down, use the
sys power slot {slot[-slot][,...]}
command to bring the
module back online.
Fan speed
The cooling module fan speed increases as the temperature reading of the sensors increases. The
cooling module fan speed decreases as the temperature reading of the sensors decreases.
System temperature information
Each of the zones correspond to temperature sensors on the modules. For instance, the I/O module
has five temperature zones. Zones 1, 2, and 3 are inlet air sensors and 4 and 5 are outlet air
sensors. The SF module has two temperature sensors and the CP module has four temperature