62
Robot 185
Service display
The frame valve related messages:
Broken circuit in controlled left / right outrigger output
Failure in the control cable or in a valve. Check the wiring and
contact service.
Error in left / right outrigger parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in left / right track feedback input
Feedback without control in left / right track feedback input.
Malfunction on wires or wiring. Possible short circuit to voltage.
Contact service.
Short circuit in controlled left / right outrigger output
Damaged valve or control cable and short circuit to earth po-
tential. Contact service.
Broken circuit in controlled left / right track output
Failure in the control cable or in a valve. Check the wiring and
contact service.
Error in left / right track parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in left / right outrigger feedback
input
Feedback without control in left / right outrigger feedback
input. Malfunction on wires or wiring. Possible short circuit to
voltage. Contact service.
Short circuit in controlled left / right track output
Damaged valve or control cable and short circuit to earth po-
tential. Contact service.
The tower valve related messages:
Short circuit in selector valve output
Short circuit in attachment selector valve, in its cable or module
output. The valve is damaged, broken cable or short circuit to
voltage.
Short circuit to external voltage in selector valve output
Voltage without control in attachment selector valve, in its cable
or module output. The valve is damaged, broken cable or short
circuit to voltage.
Broken circuit in tool tilt output
Broken circuit in tool tilt control valve or cable. The valve or
cable is damaged.
Error in tool tilt parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in tool tilt feedback input
Feedback without control in tool tilt feedback input. Malfunc-
tion on wires or wiring. Possible short circuit to voltage. Con-
tact service.
Short circuit in tool tilt output
Short circuit in control valve, cables or module output. The
valve or cable is damaged and short circuit to earth potential.
Broken circuit in tower turn output
Broken circuit in tower turn control valve or cable. The valve or
cable is damaged.
Error in tower turn parameters
Wrong setting on parameters. Check the parameter values.
Feedback without control in tower turn feedback input
Feedback without control in tower turn feedback input. Mal-
function on wires or wiring. Possible short circuit to voltage.
Contact service.
Summary of Contents for Robot 185
Page 11: ...11 Robot 185 Structure 795 1820 2030 1590 107 2290 2090 0 1 2 3 4 5 1 2 2 3 1 0 1 2 3 4 5 6 ...
Page 19: ...19 Robot 185 Structure Control system 1 Control box 2 Switch panel 3 Control lever ...
Page 66: ...66 Robot 185 Electric diagrams 400 V system and soft start ...
Page 67: ...67 Robot 185 Electric diagrams Frame module and CAN bus ...
Page 68: ...68 Robot 185 Electric diagrams Frame valves and sensors ...
Page 69: ...69 Robot 185 Electric diagrams Tower module and rotating connector ...
Page 70: ...70 Robot 185 Electric diagrams Tower module and valves ...
Page 71: ...71 Robot 185 Electric diagrams Emergency stop circuit and remote control ...