![AVANT Robot 185 Operator'S Manual Download Page 37](http://html1.mh-extra.com/html/avant/robot-185/robot-185_operators-manual_3025066037.webp)
37
Robot 185
Service
Control system
The control system does not require any special service.
Checking the control cable
You should check the control cable regularly.
A faulty control cable is one of the common reasons for machine shutdowns.
If there is an undamaged control cable available, you can use it to check whether the control cable is faulty.
Otherwise:
• Check the control cable visually for external damages.
• Shut down the motor and remove the supply cable, and ensure that it is not plugged in by mistake.
• Remove the control cable.
• Measure a possible break or short circuit in the control cable with an ohmmeter or with an equivalent device.
Summary of Contents for Robot 185
Page 11: ...11 Robot 185 Structure 795 1820 2030 1590 107 2290 2090 0 1 2 3 4 5 1 2 2 3 1 0 1 2 3 4 5 6 ...
Page 19: ...19 Robot 185 Structure Control system 1 Control box 2 Switch panel 3 Control lever ...
Page 66: ...66 Robot 185 Electric diagrams 400 V system and soft start ...
Page 67: ...67 Robot 185 Electric diagrams Frame module and CAN bus ...
Page 68: ...68 Robot 185 Electric diagrams Frame valves and sensors ...
Page 69: ...69 Robot 185 Electric diagrams Tower module and rotating connector ...
Page 70: ...70 Robot 185 Electric diagrams Tower module and valves ...
Page 71: ...71 Robot 185 Electric diagrams Emergency stop circuit and remote control ...